Skip to content

SCA Pharmaceuticals LLC Form 483, March 2026

FDA issued this Form 483 to SCA Pharmaceuticals LLC in Windsor, Connecticut (FEI 3013736415) at the end of an inspection that ended March 13, 2026. It lists 3 observations.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted May 8, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Mar 13, 2026
—
FDA's outcome
Not classified
Not classified yet
Posted by FDA
May 8, 2026
56 days after the inspection
Facility
FEI 3013736415
Windsor, Connecticut

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate microbiological contamination controls

    Procedures designed to prevent microbiological contamination are not established and followed. Specifically, A. Your firm has initiated approximately 46 Excursion (EXC), representing reports for microorganisms recovered from the ISO-5 critical zone in the Laminar Flow Hoods where sterile drug products are compounded. Since December 2024 organisms recovered included Staphylococcus species (epidermidis, hominis, capitis, haemolyticus), Bacillus simplex (clausii, infantis, circulans), Corynebacterium tuberculostearicum, Micrococcus luteus, and other organisms such as Kocuria, Peribacillus, Paenibacillus, Fictibacillus, Streptomyces, Cladosporium, Sphigmonas and Penicillium citrinum. These organisms are either spore forming, or non-spore forming organisms recovered from either gloved fingertip, sleeve monitoring, active air, and/or passive air samples. Of the approximate 46 excursions initiated affecting multiple product batches including Phenylephrine HCL 100mcg, Oxytocin, Sucinylchlorine Chloride, Fentanyl Citrate, Labetalol, Rocuronium Bromide, Hydromorphone HCL, Diltiazem DCL and a Media Fill batch, [illegible] been rejected and [illegible] has been released. Product Name Sample Personnel Method Fentanyl Citrate Compounder 1 (b)(4) (b)(4) 2 mcg/mL Bupivacaine HCl 0.1% in 0.9% Sodium Chloride 250 mL Bag, Lot: 1225059964 BUD: 24 SEP 2025 (Intrathecal) Aseptic Assistant (b)(4) (b)(4) * NIA = the organism was unable to be subcultured; therefore, no identification was performed. B. Compounders and Aseptic Assistants were observed not using slow and deliberate movements in the ISO-5 Laminar Flow Hoods or during compounding activities on [illegible], not holding their hands and arms in a position within the manufacturing workspace to minimize potential air turbulence. Furthermore, Compounders and Aseptic Assistants were observed using their feet to kick garbage receptacles, power cords on the floor and non-viable probes throughout the ISO-7 manufacturing area. These actions can potentially aerosolize particles and microorganisms from the floor, which can then draw into the ISO-7 clean room and subsequently into the ISO-5 Laminar Flow Hoods. C. Your firm utilizes the (b)(4) air sampling collection device to perform air sampling in the Laminar Air Flow Hoods. You have not adequately determined that placing the unit [illegible] while conducting the test does not violate first air principles by pushing air deflected from the unit into the critical workspace and creating potential reflux. D. Your operators were observed utilizing sterile goggles that utilize the (b)(4). You have not provided an adequate rationale to support the use of these goggles in the sterile core. The sterile goggles have [illegible] potential particulates from operator's skin to egress into the surrounding environment. The sterile goggles are part of the sterile gowning used for operators in your clean room and when preparing products intended to be sterile in your [illegible]. E. Operators conducting cleaning were observed using materials prepared in the ISO-7 clean room such as lint free dry wipes saturated in buckets [(b)(4)] wipes to clean inside the laminar flow hood and outside of the hood.

  2. 2

    Failure to investigate particulate discrepancies

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, • Your firm failed to identify the root cause for particulate contamination in products intended to be sterile and failed to implement effective corrective and preventive actions to prevent recurrence. These deviation investigations have been described as Investigation Major Particulate Matter DRL Threshold Exceedance, 100% Visual Inspection Particulate Matter Threshold Exceedance, AQL Failure, and Major DRL Particulate Matter Threshold Exceedance. Since December 2024, your firm has initiated approximately 110 deviation investigations due to visual inspection failures for particulates. The majority were initiated due to contaminates observed that present as material found on the plunger, floating particulate, or adhered to the stopper barrel. Despite this recurring pattern of contamination, your firm has not: • Conducted a thorough investigation to determine the definitive root cause(s) of particulate failures. • Implemented corrective and preventive actions (CAPA) that address the underlying cause(s) of particulate contamination. • Demonstrated the effectiveness of any corrective actions taken to prevent the continued occurrence of intrinsic particulates. • Adequately justified the classification of "Major" for particulate contamination. The repeated occurrence of intrinsic particulate failures without adequate investigation and effective CAPA demonstrates a failure to maintain your manufacturing process in a state [illegible].

  3. 3

    Inadequate cleaning/disinfectant procedures

    Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing. Your firm's VAL-24-076-FR, Disinfectant Efficacy Study for the Connecticut Facility Located at 755 Rainbow Road, Windsor, CT 06095, Rev. 1 established a (b)(4) dwell time when cleaning with (b)(4) to disinfect all classified areas. The following deficiencies were noted in VAL-24-076- Rev. 1, December 2024. 1. No evaluation of other organisms other than Bacillus altitudinis/pumilus/safensis. The firm has recovered other spore forming organisms from the ISO-5 sterile compounding core including: Cladosporium and related organisms. According to the manufacturer's instructions for (b)(4), [illegible] is required to effectively use (b)(4) for reduction in the presence of bacteria, mold and other spore forming organisms.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3013736415, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.