Environmental monitoring in FDA Form 483 observations
Monitoring cleanrooms and the people in them: viable and nonviable air sampling, settle and contact plates, glove and fingertip samples, and the results that should trigger action. FDAgent finds 179 such observations in 116 Form 483s issued to 109 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 179
- Each quoted below
- Form 483s
- 116
- Posted by FDA
- Facilities
- 109
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 64 in 2026
| Year | Observations |
|---|---|
| 2008 | 2 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 2 |
| 2013 | 0 |
| 2014 | 2 |
| 2015 | 2 |
| 2016 | 11 |
| 2017 | 9 |
| 2018 | 6 |
| 2019 | 5 |
| 2020 | 1 |
| 2021 | 14 |
| 2022 | 14 |
| 2023 | 13 |
| 2024 | 11 |
| 2025 | 23 |
| 2026 | 64 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“environmental monitoring” · “viable” · “nonviable” · “non viable” · “settle plate*” · “contact plate*” · “personnel monitoring” · “fingertip*” · “glove print*” · “glove sampl*” · “particle count*” · “air sampl*” · “surface sampl*” · “EM program*” · “EM sampl*” · “EM data” · “EM excursion*” · “EM result*” · “EM plate*”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 179 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Glenmark Pharmaceuticals LimitedInspection ended Jun 30, 2026 · FEI 3004672766 · Observation 4
… including an assessment of the location and (b)(4) points of the (b)(4) systems in relation to the (b)(4) facility; the adequacy and a program for periodic environmental monitoring between the facilities; the (b)(4) vents of the (b)(4) facility's (b)(4).
Contains “environmental monitoring”Read the Form 483 →
Dr. Reddy's Laboratories Ltd.Inspection ended Jun 25, 2026 · FEI 3014250111 · Observation 2
Aseptic processing environmental monitoring procedures are inadequate in the (b)(4) filling line. Specifically, A. On June 24, 2026, following filling of (b)(4) drug product batch number (b)(4), environmental monitoring failed to include viable surface monitoring of the (b)(4) and stopper bowl. The inadequate (b)(4) design does not allow for effective monitoring strategies for these indirect product-contact surfaces, which compromises sterility …
Contains “environmental monitoring”Read the Form 483 →
Eugia Steriles Private LimitedInspection ended Jun 19, 2026 · FEI 3027357163 · Observation 1
… This includes the lack of airflow studies for planned interventions, such as changes in environmental monitoring (EM) settle plates and active air sampling plates, which occur approximately (b)(4). In addition there is no environmental monitoring on the opposite side of the (b)(4) (Length: (b)(4) and Width (b)(4)) used to (b)(4) load (b)(4) vials for approximately (b)(4) at a time prior to being moved and transferred to the (b)(4) machine. D. The …
Contains “environmental monitoring”Read the Form 483 →
Fayetteville VA Medical CenterInspection ended Jun 15, 2026 · FEI 1073803 · Observation 1
Microbial contamination was present in the [illegible]. Specifically. On 05/08/2025, a surface sample collected from (b)(4) (S/N: (b)(4)), an ISO Class 5 (b)(4) used for the production of sterile drug products, yielded 4 cfu/plate, exceeding the action limit of [illegible] cfu/plate. The sample was classified as Out of Compliance (OOC) and the following organisms were identified: Cladosporium spp. (pathogenic), Corynebacterium tuberculostearicum, …
Contains “surface sampl*”Read the Form 483 →
Lyophilization Services of New England, Inc. dba PCI Pharma ServicesInspection ended Jun 10, 2026 · FEI 3008546445 · Observation 1
… Your firm failed to perform environmental monitoring to evaluate the risk to ISO-5 environments during critical process interventions. Specifically, during filling of drug product your firm's (b)(4) process involves opening a (b)(4) door in ISO-5/6 Room (b)(4) to load (b)(4) into the filling line hopper, exposing the Grade A (b)(4) interior to the surrounding room. Your firm does not perform environmental monitoring in the vicinity of this …
Contains “environmental monitoring”Read the Form 483 →
Lyophilization Services of New England, Inc. dba PCI Pharma ServicesInspection ended Jun 10, 2026 · FEI 3008546445 · Observation 2
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, your firm's investigations into personnel monitoring (PM) action level excursions at failed to assess aseptic gowning practices such as the use of (b)(4) goggles as a potential root cause. Data for the facility shows action level recoveries of skin flora at the chest and/or forehead of 1 CFU/mL or more in your …
Contains “personnel monitoring”Read the Form 483 →
Lyophilization Services of New England, Inc. dba PCI Pharma ServicesInspection ended Jun 10, 2026 · FEI 3008546445 · Observation 3
… SOP-07617, "Routine Environmental Monitoring of Non-Aseptic Area at (b)(4)" Revision 2, Effective date 06 November 2024 specifies for Grade C space surrounding the (b)(4) fill line (room (b)(4)), Section 7.2.3: Rooms associated with non-aseptic areas will be routinely monitored as found, Note: (b)(4) per SOP-07618. You fail to conduct environmental monitoring within Grade D and C space during manufacture, under dynamic conditions in assurance the …
Contains “environmental monitoring”Read the Form 483 →
Lyophilization Services of New England, Inc. dba PCI Pharma ServicesInspection ended Jun 10, 2026 · FEI 3008546445 · Observation 4
… The (b)(4) water system used as (b)(4) water for the multiple effect still and clean (b)(4) generator fails to have water environmental monitoring testing conducted at any frequency to a specification. b. The (b)(4) distribution system used in back fill of the (b)(4) and a point of use drop at the (b)(4) fill line fails to have environmental monitoring testing conducted at any frequency to a specification. c. Observed in Grade C space surrounding …
Contains “environmental monitoring”Read the Form 483 →
PQ Pharmacy LLCInspection ended Jun 1, 2026 · FEI 3017374013 · Observation 1
… C) Personnel monitoring (PM) conducted following media fill activities is not representative of locations which may contribute to microbial contamination during aseptic operations. For example, PM is limited to, which you identify as (b)(4), while sampling of (b)(4) the head and chest areas are not performed, despite these regions routinely breaching the ISO-5 environment during operations. Process Validation D) You have not performed process …
Contains “personnel monitoring”Read the Form 483 →
PQ Pharmacy LLCInspection ended Jun 1, 2026 · FEI 3017374013 · Observation 5
The responsibilities and procedures applicable to the quality control unit are not in writing. Specifically, you have not established a procedure to ensure critical data is reviewed and verified by a second person prior to batch release. For example, A) Data generated from environmental monitoring (EM) plates post incubation are read by a (b)(4) (b)(4) and are not subject to a (b)(4) review. Observations interpreted from the original data (EM …
Contains “environmental monitoring”Read the Form 483 →
PQ Pharmacy LLCInspection ended Jun 1, 2026 · FEI 3017374013 · Observation 6
… For example, during the simulations, materials such as stacks of environmental monitoring (EM) plates and an air sampler were positioned at the (b)(4) of the hood, obstructing the recirculation vents. Because these areas were not evaluated, the smoke studies do not adequately characterize airflow behavior in the vicinity of these materials, leaving critical zones unassessed. These smoke studies are intended to simulate the production of sterile …
Contains “environmental monitoring”Read the Form 483 →
PETNET Solutions Inc.Inspection ended May 22, 2026 · FEI 3036193770 · Observation 4
… B) The operator placed the environmental monitoring (EM) settle plate cover face up of the in the critical zone during active aseptic operations. C) Materials and components were positioned in front of one another, obstructing first-air flow. D) During the cleaning, the operator did not employ (b) (4) wipe strokes. In addition, the operator used wipes from an already opened package. E) The operator did not (b) (4) and (b) (4) and (b) (4) on to …
Contains “environmental monitoring”Read the Form 483 →
VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 4
… No sporicidal agent is used to clean these devices, and no environmental monitoring is performed to assess the contamination risk they may introduce.
Contains “environmental monitoring”Read the Form 483 →
VA San Diego Healthcare SystemsInspection ended May 8, 2026 · FEI 2071629 · Observation 9
… No sporicidal agent was used to clean these items and no environmental monitoring was performed to assess the contamination risk they may introduce.
Contains “environmental monitoring”Read the Form 483 →
Jiangsu Hansoh Pharmaceutical Group Co Ltd.Inspection ended Apr 24, 2026 · FEI 3008316144 · Observation 4
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, the following discrepancies were noted during review of the environmental monitoring program: A. Not all (b) (4) used during aseptic filling of injectable products are sampled at the end of the batch. C-VP-206-71000-2617 Risk Assessment of Environmental Control in Workshop (b) (4) specifies sampling of (b) (4) to monitor after batch …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
Nice-Pak Products, LLCInspection ended Apr 20, 2026 · FEI 1822410 · Observation 2
Written procedures, designed to prevent objectionable microorganisms in drug products not required to be sterile, are deficient. Specifically, Your environmental monitoring program, governed by SOP QAS-094, "Microbial Environmental Monitoring," Rev. 6, is inadequate as it omits sampling of critical product-contact surfaces. Your firm does not perform microbial sampling of the internal surfaces of drug product mixing and storage tanks These …
Contains “environmental monitoring”Read the Form 483 →
USV Private LimitedInspection ended Apr 17, 2026 · FEI 3004086192 · Observation 1
… An operator was observed breaching first air by reaching over open sterile bottles near the (b) (4) (b) (4) during the replacement of viable air sampling plates. The bottles exposed during this breach were not removed from the line. During this intervention, the RABS (b) (4) was (b) (4) a Grade B environment and (b) (4) operator, gowned to Grade B standards, performed a sanitization procedure on the (b) (4) which was (b) (4) into the Grade B …
Contains “viable”Read the Form 483 →
USV Private LimitedInspection ended Apr 17, 2026 · FEI 3004086192 · Observation 5
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, or followed. Specifically, personnel monitoring procedures for aseptic operations are inadequate. The finger dabbing method consisting of touching the plate with four fingers together instead of rolling each finger separately was observed on the following occasions: A. April 9, 2026: During the setup for sterile …
Contains “personnel monitoring”Read the Form 483 →
Lonza Biologics, Inc.Inspection ended Apr 16, 2026 · FEI 3001451441 · Observation 1
… Results showed that the (b)(4) maximum capacity HD batches failed to meet protocol specifications for number of non-environmental monitoring (EM) deviations per batch, number of EM deviations per batch, exceeding a process acceptable range (PAR) for (b)(4), and an out-of-specification (OOS) result for (b)(4) testing. e) Beginning on 1/23/2026, (b)(4) commercial batches were manufactured with the updated process (b)(4). Batch No. (b)(4) was …
Contains “environmental monitoring”Read the Form 483 →
Lonza Biologics, Inc.Inspection ended Apr 16, 2026 · FEI 3001451441 · Observation 2
… Additionally, since 8/7/2025, your firm has initiated approximately (b)(4) EM deviations and approximately (b)(4) EM excursion investigations for (b)(4) activities. c) DEV-1431374 was opened on 10/22/2025 after a trend was identified for repeated alert and action level (b)(4) excursions in the (b)(4) Grade (b)(4) suite (Room (b)(4)) during APS activities conducted from (b)(4). CAPA-1447254 was initiated on 11/18/2025 to evaluate (b)(4) materials …
Contains “EM excursion*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.42Design and construction featuresIn this theme's rule30
- 21 CFR 211.113Control of microbiological contamination27
- 21 CFR 211.160General requirements6
- 21 CFR 211.192Production record review5
- 21 CFR 211.100Written procedures; deviations3
- 21 CFR 211.22Responsibilities of quality control unit2
- 21 CFR 211.63Equipment design, size, and location2
- 21 CFR 211.67Equipment cleaning and maintenance2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2
- 21 CFR 211.194Laboratory records2
Ask FDAgent about environmental monitoring in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.