Skip to content

Environmental monitoring in FDA Form 483 observations

Monitoring cleanrooms and the people in them: viable and nonviable air sampling, settle and contact plates, glove and fingertip samples, and the results that should trigger action. FDAgent finds 179 such observations in 116 Form 483s issued to 109 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
179
Each quoted below
Form 483s
116
Posted by FDA
Facilities
109
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 64 in 2026

Environmental monitoring observations in Form 483s by inspection year
YearObservations
20082
20090
20100
20110
20122
20130
20142
20152
201611
20179
20186
20195
20201
202114
202214
202313
202411
202523
202664

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.42(c)(10)(iv)

A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“environmental monitoring” · “viable” · “nonviable” · “non viable” · “settle plate*” · “contact plate*” · “personnel monitoring” · “fingertip*” · “glove print*” · “glove sampl*” · “particle count*” · “air sampl*” · “surface sampl*” · “EM program*” · “EM sampl*” · “EM data” · “EM excursion*” · “EM result*” · “EM plate*”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 179 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Apotek Production & Laboratorier ABInspection ended Jan 29, 2026 · FEI 3003766921 · Observation 3

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Your firm does not have a risk assessment to justify the environmental monitoring and personal monitoring locations and frequencies. 1. There is no surface monitoring on the Grade A aseptic filling line. ge used to fill the ge drug. While reviewing machine set up of the media fill dated September 15, 2025, and while observing …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  2. Apotek Production & Laboratorier ABInspection ended Jan 29, 2026 · FEI 3003766921 · Observation 7

    Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, your firm has omitted the g@ °C incubation step during incubation of the plates used to conduct environmental monitoring of all classified areas and operators. No method suitability study was performed or able to …

    Contains “environmental monitoring”Read the Form 483 →

  3. Centrient Pharmaceuticals India Private LimitedInspection ended Jan 27, 2026 · FEI 3004497364 · Observation 3

    Failure to have the procedures and processes necessary to ensure the API and intermediates manufactured at your facility meet established specifications for quality and purity. Specifically, Your firm's procedure SOP No. 001480: SOP for Environmental Monitoring of (b)(4) Content, Revision No. 12, Effective Date: 07/09/2025, is deficient. Your firm failed to monitor critical entry points; outside/exterior door handles from the external environment …

    Contains “environmental monitoring”Read the Form 483 →

  4. Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 1

    Laboratory records are deficient in that they do not include a complete record of all data obtained during testing. Specifically, deficiencies in documentation and data integrity were identified in environmental monitoring and (b) (4) testing records. The records and data for these quality control activities do not demonstrate adequate integrity controls and documentation practices. A) Failing non-viable particulate testing data present in the …

    Contains “environmental monitoring”Read the Form 483 →

  5. SMS Pharmaceutical Limited - Unit VIIInspection ended Dec 12, 2025 · FEI 3008654585 · Observation 1

    … matter (GTP/QC/018 Version 03 Effective 17OCT2025) has the established specifications below: (b) The procedure states to test b,><4> d you use the resulting particle count from ~><4> ~ to determine established specifications. For example, the in-house batch number b,><4> USP was tested for extraneous matter on 11DEC2025. The result for ~ and passing. However, the result is i<t>> particles for ~ which would be a failing result. This batch was …

    Contains “particle count*”Read the Form 483 →

  6. Wizcure Pharmaa Private LimitedInspection ended Dec 10, 2025 · FEI 3030304532 · Observation 1

    Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards Specifically, Microbiologists responsible for performing sterility testing and collecting environmental monitoring, personnel monitoring, and (b)(4) samples confirmed they do not collect, test, and incubate all samples. A. During inspection of the (b)(4) Biological incubators …

    Contains “environmental monitoring”Read the Form 483 →

  7. Wizcure Pharmaa Private LimitedInspection ended Dec 10, 2025 · FEI 3030304532 · Observation 5

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. A. Personnel monitoring program has not been implemented for any aseptic operations. Personnel monitoring regarding aseptic connections has never been conducted. B. Surface monitoring has never been performed on any equipment surfaces including critical product contact surfaces such as (b)(4) product contact locations including (b)(4). C. Active …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  8. Huons Co., LtdInspection ended Nov 21, 2025 · FEI 3007163376 · Observation 6

    … At the end of each batch production, only the (b)(4) glove is sampled per viable EM procedure. No fingers are monitored. You lacked justification for not monitoring gloves that are used during production and not sampling glove fingers.

    Contains “viable”Read the Form 483 →

  9. HEC Pharm Co. Ltd.Inspection ended Nov 21, 2025 · FEI 3006259537 · Observation 3

    The culture media (b)(4) used for microbial enumeration and environmental monitoring is not validated or adequately validated to determine its capability to support the growth of specific microorganisms. Specifically, growth promotion testing was not performed on the culture media used for surface microbial water was used for monitoring in the laboratories. In addition, (b)(4) used to evaluate foreign microorganism in the (b)(4) growth promotion …

    Contains “environmental monitoring”Read the Form 483 →

  10. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 2

    … The operator's gowning is sampled for environmental monitoring at the end of setup and held to Grade B limits. B. Airflow visualization study #E2-MIS-VSP-0066, effective June 19, 2023 (Line (b) (4) Filling). During interventions (b) (4) (Transfer of Manifold from (b) (4) LAF (b) (4) LAF-06 to Filling Line) and (b) (4) (Connecting Manifold to (b) (4) Tank and Fixing (b) (4) Tubing) in the Grade A area of filling line (b) (4) the following …

    Contains “environmental monitoring”Read the Form 483 →

  11. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 4

    … Additionally, no personnel monitoring is conducted after movement from Grade A to Grade B.

    Contains “personnel monitoring”Read the Form 483 →

  12. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 5

    Aseptic processing areas deficient regarding system for monitoring environmental conditions. Your environmental monitoring program is inadequate in assessing and monitoring all the potential critical surfaces, conditions and equipment in your aseptic processing areas. A. Non-viable particle count (NVPC) (b) (4) monitoring in Grade B areas is performed only once during product batch activity as per step (b) (4) of procedure EP2-PLA-SOP-012-08, …

    Contains “environmental monitoring”Read the Form 483 →

  13. Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 9

    … process for (b) (4) Injection USP (b) (4) g/vial, Batch: (b) (4) (USA market), your operator was observed placing an uncleaned (b) (4) stand (used for Environmental Monitoring activities) directly onto the conveyor belt that had been previously cleaned. This inadequate practice was also noted during the sanitization process of the filling line.

    Contains “environmental monitoring”Read the Form 483 →

  14. UBI Pharma Inc.Inspection ended Oct 14, 2025 · FEI 3004713402 · Observation 3

    … In one of the (6)(4) intervention, Place and take Out Settle Plate (Document No. PQ/GT2.3.224 Version 01, Section 4.7.4 pages 20 and 21), operator was seen to stretch out the hand over the almost entire length of [illegible]. In a similar intervention, Adjust parts' angle/position (PQ/GT2.3.224 Version 02), operator was seen hastily moving hands over the open vials and pushing the vials into the line back onto the (6)(4). Your SOP No. P366 …

    Contains “settle plate*”Read the Form 483 →

  15. Sun Pharmaceuticals Medicare Ltd.Inspection ended Sep 19, 2025 · FEI 3002957541 · Observation 1

    … Also, during hand sanitization, I observed sterile (b)(4) was sprayed near the Grade A EM settling plates and active air sampler, possibly contaminating the (b)(4) media. e). Sterile articles were transferred to the Grade B filling room using a (b)(4) LAF (b)(4) Operators did not sanitize their hands before reaching inside the Grade A (b)(4) LAF (b)(4) Also, the interior Grade A side of the (b)(4) LAF (b)(4) that had been exposed to the Grade B …

    Contains “air sampl*”Read the Form 483 →

  16. Sun Pharmaceuticals Medicare Ltd.Inspection ended Sep 19, 2025 · FEI 3002957541 · Observation 2

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. During review of the environmental and personnel monitoring (EM and PM), the following was noted: A. From 01/2023 to date, a total of (4) batches were rejected due to EM or PM excursions. (4) of the rejections involved manufacturing Block (b)(4) PM excursions (Action limits for Grade A: (b)(4) Grade B: (4) cfu/plate or NMT (b)(4) cfu (b)(4) gown …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  17. Aptuit LtdInspection ended Aug 22, 2025 · FEI 3003444315 · Observation 4

    … On December 11, 2024, the quality unit learned that since the year 2012, the approved contract laboratory performing the microbiological testing (i.e., Total Viable Count (TVC) and endotoxins) for the [illegible] used for the manufacture of APIs and excipients neither has UKAS accreditation for the test requirements nor do they conduct their analyses according to USP or EP standard. At the time of my inspection, the quality unit continues …

    Contains “viable”Read the Form 483 →

  18. Hikma Injectables USA Inc.Inspection ended Aug 8, 2025 · FEI 3022897129 · Observation 3

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, The firm's procedure for collecting active viable air within the ISO-5 laminar airflow hood is not representative of the full duration of the sterile production process. The firm will only collect [illegible] of air within approximately [illegible] and that the production process within the laminar airflow hood lasts approximately …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  19. Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 3

    … Non-classified areas lack continuous monitoring of differential pressures as well as non-viable particles. B. Air pressure differential limit setpoint alarms and alarm delays are not scientifically established nor monitored regarding your ISO 7 room where you produce sterile drug product(s). You did not establish real-time setpoint limit alarms according to your written SOPs such that your SOP requires differential pressures of [illegible] W.C. …

    Contains “non viable”Read the Form 483 →

  20. Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 4

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Personnel and environmental monitoring during and after your aseptic connection as well as throughout aseptic production is not scientifically performed. 1. The system by which you conduct personnel monitoring is not scientifically established. I observed personnel enter your ISO 5 environment with their hands and arms. You do not …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about environmental monitoring in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.