Skip to content

Aptuit Ltd Form 483, August 2025

FDA issued this Form 483 to Aptuit Ltd in Abingdon, United Kingdom (FEI 3003444315) at the end of a drug inspection that ended August 22, 2025. It lists 7 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jul 28, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Aug 22, 2025
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Jul 28, 2026
340 days after the inspection
Facility
FEI 3003444315
Abingdon, United Kingdom

The 7 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Quality unit responsibilities not followed

    The responsibilities applicable to the quality unit are not fully followed. Specifically, Since June 2023, approximately [illegible] batches of [illegible] were released to the market without assurance that they had safety levels of [illegible]. Additionally, the quality unit failed to develop a Risk Assessment of the Presence of [illegible].

  2. 2

    Failure to investigate discrepancies/complaints

    There is a failure to thoroughly review any unexplained discrepancy and the failure to [illegible] of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, The quality unit failed to perform a thorough customer complaint investigation regarding [illegible] batches of [illegible] API that obtained [illegible] contents above the specifications limits. The quality unit neither performed testing to the APIs to detect [illegible] nor established a corrective and preventive action to avoid recurrence. These APIs were sent to the US market and other markets.

  3. 3

    No procedures to prevent microbial contamination

    Procedures designed to prevent microbiological contamination of products purporting to be non-sterile are not established. Specifically, a. The quality unit fails to ensure that the contract laboratory that performs the testing for the [illegible] system used for the manufacture of APIs (i.e. [illegible] and excipient, [illegible]) has adequate and validated test methods. b. The quality control unit failed to ensure that the [illegible] system used for the manufacture of APIs and excipient has safety level of [illegible].

  4. 4

    Deficient contract lab approval system

    The quality system to approve contract laboratories to perform microbiological testing of APIs, and excipients is deficient. Specifically, 1. The quality unit fails to ensure that the approved contract laboratory used to perform testing of APIs and excipient has the capabilities, equipment, test methods, knowledge, and reliability needed to perform the testing in an accurate and reliable way. 2. On December 11, 2024, the quality unit learned that since the year 2012, the approved contract laboratory performing the microbiological testing (i.e., Total Viable Count (TVC) and endotoxins) for the [illegible] used for the manufacture of APIs and excipients neither has UKAS accreditation for the test requirements nor do they conduct their analyses according to USP or EP standard. At the time of my inspection, the quality unit continues utilizing this deficient laboratory and continues accepting its questionable test results of [illegible] (ie, TVC and [illegible] endotoxins) to approve and release APIs and excipients to the market. Firm's manufactures [illegible] API intended for sterile injectable and other APIs intended for drug substances.

  5. 5

    Microbiological methods not validated

    The accuracy, sensitivity, specificity, reproducibility, and reliability of microbiological test methods has not been established. Specifically, The quality unit fails to ensure that the microbiological test methods (e.g., TVC, pathogens identification, and endotoxins) utilized for the release of APIs [e.g., [illegible] (intended for drug product), [illegible] (intended for sterile injectable) and excipient [illegible]] are validated.

  6. 6

    Raw material identity not verified

    The identity of each raw material of drug substance is not verified by conducting at least one test to verify the identity, using specific identity test. Specifically, The quality control unit fails to establish a specific identification test method for a raw material used for the manufacture of API, or [illegible].

  7. 7

    Sampling amount criteria not established

    The amount of material taken from each container is not based upon appropriate criteria. Specifically, The quality unit fails to ensure that the amount of raw material taken for testing is based upon appropriate criteria such as criticality of the material, material variability, past history of the supplier, and the quantity needed for analysis.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.