Aptuit (Oxford) Ltd.
111 Innovation Drive, Abingdon, United Kingdom
FEI 3003444315DUNS 217370698
Company: Aptuit Global LLC · Linked by exact D-U-N-S match (080776951) in FDA registration data
FDA has 4 inspections on file for Aptuit (Oxford) Ltd. in Abingdon, United Kingdom (FEI 3003444315), from 2013 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2027. Its registrant, Aptuit Global LLC (D-U-N-S 080776951), has registered 1 other site.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2013–2025
- 0 OAI · 4 VAI · 0 NAI
- Inspections with 483 observations shown
- 1 of 4
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest May 8, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Quality unit responsibilities not followed
The responsibilities applicable to the quality unit are not fully followed. Specifically, Since June 2023, approximately [illegible] batches of [illegible] were released to the market without assurance that they had safety levels of [illegible]. Additionally, the quality unit failed to develop a Risk Assessment of the Presence of [illegible].
- Observation 2
Failure to investigate discrepancies/complaints
There is a failure to thoroughly review any unexplained discrepancy and the failure to [illegible] of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, The quality unit failed to perform a thorough customer complaint investigation regarding [illegible] batches of [illegible] API that obtained [illegible] contents above the specifications limits. The quality unit neither performed testing to the APIs to detect [illegible] nor established a corrective and preventive action to avoid recurrence. These APIs were sent to the US market and other markets.
Show observations 3 to 7
- Observation 3
No procedures to prevent microbial contamination
Procedures designed to prevent microbiological contamination of products purporting to be non-sterile are not established. Specifically, a. The quality unit fails to ensure that the contract laboratory that performs the testing for the [illegible] system used for the manufacture of APIs (i.e. [illegible] and excipient, [illegible]) has adequate and validated test methods. b. The quality control unit failed to ensure that the [illegible] system used for the manufacture of APIs and excipient has safety level of [illegible].
- Observation 4
Deficient contract lab approval system
The quality system to approve contract laboratories to perform microbiological testing of APIs, and excipients is deficient. Specifically, 1. The quality unit fails to ensure that the approved contract laboratory used to perform testing of APIs and excipient has the capabilities, equipment, test methods, knowledge, and reliability needed to perform the testing in an accurate and reliable way. 2. On December 11, 2024, the quality unit learned that since the year 2012, the approved contract laboratory performing the microbiological testing (i.e., Total Viable Count (TVC) and endotoxins) for the [illegible] used for the manufacture of APIs and excipients neither has UKAS accreditation for the test requirements nor do they conduct their analyses according to USP or EP standard. At the time of my inspection, the quality unit continues utilizing this deficient laboratory and continues accepting its questionable test results of [illegible] (ie, TVC and [illegible] endotoxins) to approve and release APIs and excipients to the market. Firm's manufactures [illegible] API intended for sterile injectable and other APIs intended for drug substances.
- Observation 5
Microbiological methods not validated
The accuracy, sensitivity, specificity, reproducibility, and reliability of microbiological test methods has not been established. Specifically, The quality unit fails to ensure that the microbiological test methods (e.g., TVC, pathogens identification, and endotoxins) utilized for the release of APIs [e.g., [illegible] (intended for drug product), [illegible] (intended for sterile injectable) and excipient [illegible]] are validated.
- Observation 6
Raw material identity not verified
The identity of each raw material of drug substance is not verified by conducting at least one test to verify the identity, using specific identity test. Specifically, The quality control unit fails to establish a specific identification test method for a raw material used for the manufacture of API, or [illegible].
- Observation 7
Sampling amount criteria not established
The amount of material taken from each container is not based upon appropriate criteria. Specifically, The quality unit fails to ensure that the amount of raw material taken for testing is based upon appropriate criteria such as criticality of the material, material variability, past history of the supplier, and the quantity needed for analysis.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on May 8, 2026. It asked for a Form 483.
Inspection ending Aug 22, 2025VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- May 8, 2026FDA-FOIA-2026-4748Form 483· 1 of 2 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Aptuit Global LLCD-U-N-S 080776951
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Aptuit Global LLC (D-U-N-S 080776951) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Aptuit (Verona) SrlVerona, Italy · FEI 30086614445 inspections5latestNov 10, 2023VAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3003444315 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3003444315. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.