Personnel training in FDA Form 483 observations
Whether the people doing the work are trained for it, and whether the training is documented. FDAgent finds 74 such observations in 64 Form 483s issued to 64 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 74
- Each quoted below
- Form 483s
- 64
- Posted by FDA
- Facilities
- 64
- Distinct FEIs
- Most recent
- Sep 3, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 19 in 2026
| Year | Observations |
|---|---|
| 2008 | 1 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 1 |
| 2013 | 0 |
| 2014 | 0 |
| 2015 | 0 |
| 2016 | 6 |
| 2017 | 4 |
| 2018 | 7 |
| 2019 | 3 |
| 2020 | 0 |
| 2021 | 2 |
| 2022 | 7 |
| 2023 | 9 |
| 2024 | 5 |
| 2025 | 10 |
| 2026 | 19 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
The same entries the training topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“trained” · “training” · “untrained” · “retrain*”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 74 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Zen Chemicals Pvt. LtdInspection ended Mar 28, 2023 · FEI 3015345351 · Observation 5
Employees are not trained in cleaning procedures. Specifically, Your firm failed to train your employees who perform cleaning, verify that cleaning is adequate and recheck and approve cleaning equipment and sign final cleaning batch to batch or product to product documentation. In reviewing employee's training records, approximately six (6) employees were deficient in training on cleaning SOP, TR/15/05/013. During the inspection, six (6) …
Contains “trained”Read the Form 483 →
SciVac LTDInspection ended Mar 27, 2023 · FEI 3012695367 · Observation 2
Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions. Specifically, A. You lack scientific justification supporting your defect categories and establishment of your defect kits. Cracks are categorized with scratches and cracks are not included in your qualification kits. Furthermore, you have failed to include glass particles in your kits. i. AQLs are not …
Opens with FDA's citation wording for 21 CFR 211.25(a)Read the Form 483 →
SciVac LTDInspection ended Mar 27, 2023 · FEI 3012695367 · Observation 3
… You are not required to perform investigations upon failures regarding visual inspections and (b)(4) retraining efforts as well as gowning failures per written procedures. i. Your visual inspection operator failed multiple requalification efforts during the approximate period of 7/3/2022 through 7/28/2022 and no deviation was opened. ii. Your gowning qualification SOP does not require investigations if the operator fails (b)(4) gowning …
Contains “retrain*”Read the Form 483 →
Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 8
… in the state of control." The "Microbial identification of environment isolate aids in the evaluation of cleaning/ sanitization effectiveness, personnel training, deterioration and malfunction of AHU system and facilities." The EM and personnel monitoring samples for the Grade B area is described in the Frequency of Microbial Isolate Exhibit-II i.e., for routine plates observation to (b) (4) (b) (4) (b) (4) The Assistant Manager QC Microbiology …
Contains “training”Read the Form 483 →
Octapharma Pharmazeutika Produktionsgesellschaft m.b.H. OPGInspection ended Dec 16, 2022 · FEI 3002809097 · Observation 2
There is no assurance of effective training or accurate deviation root cause assignment for employees engaged in sampling, testing, data reporting and data review from the Quality Control Unit and Production Unit. The following deviations were reported to be due to human error or due in part to employees who were inadequately trained in the cGMP procedures. These include but are not limited to: Specifically, A. Deviation, TW#111834, dated …
Contains “training”Read the Form 483 →
DyAnsys India Pvt. Ltd.Inspection ended Dec 15, 2022 · FEI 3010350335 · Observation 1
… You did not ensure that the Principal Investigator and Study Director were trained to comply with Good Clinical Practices or to conduct the study in accordance with the protocol. E. You did not obtain a signed investigator agreement from the Principal Investigator of the study. F. You did not maintain records of shipment and disposition of study devices including: The name and address of the study staff and study site where devices were shipped …
Contains “trained”Read the Form 483 →
Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 5
Equipment used in the manufacture, processing, packing, or holding of a drug product lack appropriate design to facilitate operations for its intended use and for its cleaning and maintenance. Specifically, The Good Engineering Practices training module number MD2-TM-ENG2-FUN-001-00, dated 28/07/2021, is provided to all pertinent personnel that include the engineering department. The training includes for example, "Good engineering practices are …
Contains “training”Read the Form 483 →
Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 14
The Good Engineering Practices training module number MD2-TM-ENG2-FUN-001-00, dated 28/07/2021, is provided to all pertinent personnel that include the engineering department. The training includes for example, "Good engineering practices are to ensure that the development and/or manufacturing effort consistently generates deliverables that support the requirements for qualification or validation." The engineering drawings and specifications …
Contains “training”Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 1
… Visual inspectors were retrained in what constitutes a bent (b)(4) i.e., the (b)(4) is bent to where it extends beyond the diameter of the shoulder of the (b)(4). This definition does not consider the diameter of the (b)(4) or the length of the (b)(4). Justification for the change in the bent (b)(4) definition could not be provided. The rejected (b)(4) were not reevaluated to determine if hyper awareness of slight yet acceptable bends in the …
Contains “retrain*”Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 12
… The analysts are trained to choose between normal, don't process or don't process or report. A-SOP-09-06-180, Use of BLM Empower 3 Chromatography Data System, does not address these choices. If 'don't process or report' is chosen, these chromatograms are not processed and are not reviewed.
Contains “trained”Read the Form 483 →
Emergent Manufacturing Operations Baltimore, LLC.Inspection ended Apr 20, 2021 · FEI 3015448605 · Observation 1
… Your firm failed to investigate how the operators were trained to perform this recipe abort and initiate a new recipe technique. Your firm also failed to investigate what impact utilizing this technique has on the product during filling operations. c. On 1/19/2021, (b) (4) room ID# (b) (4) and (b) (4) corridor ID (b) (4) had logbook entries "fix (b) (4)" and "repair (b) (4)". The bulk drug substance batch (b) (4) for client (b) (4), released on …
Contains “trained”Read the Form 483 →
Emergent Manufacturing Operations Baltimore, LLC.Inspection ended Apr 20, 2021 · FEI 3015448605 · Observation 7
Employees were not trained in the particular operation that they performed and/or in CGMPs related to their job function. Specifically, The firm has failed to adequately train personnel involved in manufacturing operations, quality control sampling, weigh and dispense, and engineering operations to prevent cross contamination of bulk drug substances created for client (b) (4) and client (b) (4). Review of security camera footage found: a. …
Contains “trained”Read the Form 483 →
SCA Pharmaceuticals, Inc.Inspection ended Nov 7, 2019 · FEI 3010683157 · Observation 6
Employees engaged in the processing of a drug product lack the training required to perform their assigned functions. Specifically, employees responsible for the sterility analysis by Scan RDI are two months late in their [illegible] recertification and continue to process sterility analysis using Scan RDI.
Opens with FDA's citation wording for 21 CFR 211.25(a)Read the Form 483 →
Torrent Pharmaceuticals LimitedInspection ended Apr 16, 2019 · FEI 3005029956 · Observation 3
… Additionally, the production operators purportedly trained on the operational aspects of (b)(4)-03 confirmed that they do not know how to set up the vision profile settings for the vision inspection system on the machine. The vision system ensures that the (b)(4) tablets conform to in-process specification limits. A service engineer representative also confirmed that he is unaware of how to correctly setup the vision inspection system. …
Contains “trained”Read the Form 483 →
Sun Pharmaceutical Medicare LimitedInspection ended Feb 5, 2019 · FEI 3002957541 · Observation 1
… | [illegible] 316048 | [illegible] | IM CRT | [illegible] | [illegible] | [illegible] These tests have been performed by different analysts and all have been trained in sample preparation.
Contains “trained”Read the Form 483 →
The Pet Apothecary LLCInspection ended Aug 7, 2018 · FEI 3005946041 · Observation 5
Your pharmacy does not have an established training program for technicians nor do you maintain any training record documentation for on-the-job training that was provided to them. Dosage forms prepared by technicians range from aqueous solutions, oils/suspensions, capsules, chew treats, eye drops, to transdermals.
Contains “training”Read the Form 483 →
Celltrion Inc.Inspection ended Jul 17, 2018 · FEI 3005241015 · Observation 2
Employees engaged in the processing of a drug product lack the training required to perform their assigned functions. Specifically, Your firm performs 100% visual inspection on finished drug product. Your qualification for the operators is inadequate in that the qualification vials with glass particles are on the [illegible] of the [illegible] do not the [illegible] at the [illegible] of the vial. Your firm only utilizes photographs for training …
Opens with FDA's citation wording for 21 CFR 211.25(a)Read the Form 483 →
Galaxy Surfactants Ltd.Inspection ended Mar 30, 2018 · FEI 3004879807 · Observation 4
4. Your firm failed to provide GMP training to your employees at the particular operations that the employee performs and GMP as it relates to the employee's functions. Specifically, Only 4 out [illegible] employees (that includes technical staff and the operators as per your Site Master File, SMF-N46-00, Effective date 1/15/2018, page 13) received the GMP training in 2016 and no training was given in 2017. However, SOP # QA011-00 (Effective date …
Contains “training”Read the Form 483 →
Galaxy Surfactants Ltd.Inspection ended Mar 23, 2018 · FEI 3010166890 · Observation 1
1. You failed to provide appropriate GMP and position specific training to personnel for the particular operations that each employee performs as it relates to the employee's functions. Specifically a. The operator responsible for the receiving of raw materials was not given access to the SOP that refers to the receipt of raw materials in the warehouse. The respective document, SOP # ST002-00 (Effective date 8/19/2017), Procedure for Receiving of …
Contains “training”Read the Form 483 →
Aurobindo Pharma Ltd.Inspection ended Feb 20, 2018 · FEI 3008461619 · Observation 6
Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training required to perform their assigned functions. Specifically, during the machine set-up and filling preparation for ® injection lot # | on February 13, 2018, I observed that two operators inside the cleanroom cleaned the ©O@ that were already installed on the filling machine’s :P@ times with ®® and cloth without paying attention to the black …
Opens with FDA's citation wording for 21 CFR 211.25(a)Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.25Personnel qualificationsIn this theme's rule13
- 21 CFR 211.100Written procedures; deviations5
- 21 CFR 211.113Control of microbiological contamination4
- 21 CFR 211.192Production record review4
- 21 CFR 211.22Responsibilities of quality control unit2
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2
- 21 CFR 211.160General requirements2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1
- 21 CFR 820.25PersonnelIn this theme's rule1
- 21 CFR 820.100Corrective and preventive action1
Ask FDAgent about training in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.