Skip to content

Visual inspection and particulates in FDA Form 483 observations

Inspecting filled product for defects and visible particles, and investigating the particles and foreign matter found. FDAgent finds 143 such observations in 91 Form 483s issued to 88 facilities, for inspections that ended between June 2012 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
143
Each quoted below
Form 483s
91
Posted by FDA
Facilities
88
Distinct FEIs
Most recent
Sep 10, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 46 in 2026

Visual inspection observations in Form 483s by inspection year
YearObservations
20121
20132
20140
20150
20168
201711
20186
201910
20201
20216
20229
202317
20248
202518
202646

How FDAgent sorts observations into this theme

One fixed rule, applied by code to every observation FDAgent can quote. No model and no similarity score decides.

Its text contains one of these phrases

“visual inspection*” · “visually inspect*” · “visible particle*” · “visible particulate*” · “particulate matter” · “foreign matter” · “foreign particle*” · “foreign material*” · “AQL”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 143 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Samsung Biologics Co. Ltd.Inspection ended Sep 1, 2023 · FEI 3010479596 · Observation 2

    … According to SOP-MFP-00074, "Inspection of Process Equipment and Materials", v22, Effective date 08 August 2023, Section 8.1 includes visually inspect materials, probes, parts, and assemblies before use or installation and verify that it is integral and free of debris, surface anomalies, foreign residue, or defects. Observed was no visual inspection of the drug substance container closure systems for absence of defect or debris within each bottle …

    Contains “visually inspect*”Read the Form 483 →

  2. Samsung Biologics Co. Ltd.Inspection ended Sep 1, 2023 · FEI 3010479596 · Observation 3

    … C) MBR-00570, MBR-573, and MBR-00934 do not clearly describe the frequency of the visual inspection for bioreactor surface followed by (b) (4) for the following unit operations: (b) (4) Operation of (b) (4)L Bioreactor, (b) (4) Operation of (b) (4)L Bioreactor, and (b) (4) Operation of (b) (4)L Bioreactor.

    Contains “visual inspection*”Read the Form 483 →

  3. Jiangsu Hengrui Pharmaceuticals CO. LTD.Inspection ended Aug 29, 2023 · FEI 3003404148 · Observation 2

    … 2) Aseptically filled products are sampled and tested for visible particulate matter for Workshop (b) (4) and (b) (4) 3) Quality assurance personnel collect the environmental monitoring samples from filling operations. e) AQL manual sampling is not performed according to SOP # GR-235, Management Procedure for Visual Inspection of Injections, which requires, "First ensure that the entire batch of product has been inspected at 100%". Currently, AQL …

    Contains “visible particulate*”Read the Form 483 →

  4. Novavax CZInspection ended Jul 18, 2023 · FEI 3017847976 · Observation 5

    Corrective action was not always taken in a timely manner to prevent the repeated recurrence for (b) (4) integrity failures, for example: (b) (4) used in production process and equipment are currently visually inspected (b) (4); however, current visual inspection procedure had failed to prevent multiple (b) (4) integrity failures (A total of 25 deviations related to (b) (4) integrity test failures were reported from August 2021 to April 2023), …

    Contains “visually inspect*”Read the Form 483 →

  5. Qilu Antibiotics Pharmaceutical Co., LTD.Inspection ended May 30, 2023 · FEI 3009831352 · Observation 5

    The responsibilities and procedure applicable to the quality control unit are not in writing. Specifically, Your firm does not have established training procedures to oversee the initial and requalification of aseptic filling operators and visual inspection personnel for workshop (b) (4) units (b) (4) A. Your firm has one SOP titled QUAL116.P "Training for Manufacturing and Quality System Personnel" governing the training program in workshop (b) …

    Contains “visual inspection*”Read the Form 483 →

  6. Apollo Care LLCInspection ended Apr 5, 2023 · FEI 3013927023 · Observation 2

    … The following discrepancies were identified during review of your visual inspection qualification program: -Your employees have never been qualified on visually inspecting syringes. Your firm compounds multiple sterile drug products in syringes, including, but not limited to, Fentanyl 50 mcg/mL in 50 mL syringes for injection and Ketamine 50 mg per 5 mL in 10 mL syringes for injection. -Your employees have never been qualified on visually …

    Contains “visual inspection*”Read the Form 483 →

  7. SciVac LTDInspection ended Mar 27, 2023 · FEI 3012695367 · Observation 3

    Deviations from written production and process control procedures are not recorded or justified. Specifically, [illegible] glove. A deviation was only opened 3/19/2023 after discussing this failure with your quality management. Media fill batch (b)(4) was filled during the use of this glove. B. You are not required to perform investigations upon failures regarding visual inspections and (b)(4) retraining efforts as well as gowning failures per …

    Contains “visual inspection*”Read the Form 483 →

  8. SciVac LTDInspection ended Mar 27, 2023 · FEI 3012695367 · Observation 4

    The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, A. Procedures are not established and / or followed to manage reconciliation of visual inspection personnel qualification documentation, media fill unit inspection documentation, etc. i. Your visual inspection qualification documentation does not reconcile all vials during operator qualifications. ii. Your media fill …

    Contains “visual inspection*”Read the Form 483 →

  9. FRUEH VERPACKUNGSTECHNIK AGInspection ended Mar 24, 2023 · FEI 3010363503 · Observation 4

    … Your firm does not have adequate Quality Unit oversight of visual inspection qualification test kits and the qualification process for operators performing visual inspection operations during packaging of drug products. For example, per your firm's procedure, the (b)(4) D. There is no adequate data integrity program in place to include an adequate review of all electronic data by the Quality Assurance Unit for standalone and network systems, to …

    Contains “visual inspection*”Read the Form 483 →

  10. QuVa Pharma , Inc.Inspection ended Oct 14, 2022 · FEI 3013931875 · Observation 3

    Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, Your firm's visual inspection procedure utilized during Inspection, Labeling and Packaging (ILP) of sterile products, are deficient for the following reasons: A) The (b) (4) and defect (b) (4) that is …

    Contains “visual inspection*”Read the Form 483 →

  11. Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 1

    Your firm failed to thoroughly investigate any unexplained discrepancy or failure of a batch or any of its components to meet any of its specifications, whether or not the batch has already been distributed. Specifically, A. Per various (b)(4) batch records, the Visible Particles USP <790> testing list a specification of "(b)(4) particles observed**If (b)(4) particle is observed during initial testing, test an additional (b)(4) vials with a …

    Contains “visible particle*”Read the Form 483 →

  12. Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 2

    Written records of investigation of a drug complaint do not include the findings of the investigation and the follow-up. Specifically, A. As provided by your firm, a total of 179 complaints were received for particles (foreign matter, particulate matter, black specks, black particles, foreign particle, (b)(4) impurities, black dots and other particulates, dark particles, foreign material, foreign object, (b)(4) particulate, or pieces of (b)(4) in …

    Contains “foreign matter”Read the Form 483 →

  13. Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 4

    Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet appropriate statistical quality control criteria as a condition for their approval and release. Specifically, A-SOP-03-04-001, Performance of AQL for Parenteral Inspections, states AQL sampling should be a representation of the entire batch. "During (b)(4) Inspection with (b)(4) (System 2440), if AQL …

    Contains “AQL”Read the Form 483 →

  14. Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 5

    … Extrinsic Particulate Matter is a (b)(4) Critical Defect that is checked during visual inspection. B. 1. The product used for your (b)(4) inspection base line study (Knapp study) did not have the same properties as the product used during (b)(4) qualification. Your firm used a surrogate product for particulate analysis performed during the Knapp study A-DSR-18-01-091 as a baseline to qualify recipe (b)(4) Rev 1.1 on (b)(4) (System 2405). The …

    Contains “particulate matter”Read the Form 483 →

  15. Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 8

    … Although included in the emulsion visual inspection kit, visual inspectors for emulsion products are not qualified to detect Major A defects. This category contains fibers or intrinsic particulate matter. B. The emulsion visual inspection kits do not represent extrinsic particulate matter. C. A visual inspection kit does not exist for (b)(4) vials. Instead, the inspectors train on the aqueous glass kit. The aqueous kit does not contain the …

    Contains “visual inspection*”Read the Form 483 →

  16. Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 9

    … of performing destructive particles testing on the good vials remaining after the (b)(4) inspection, (b)(4) vials are sampled from the batch prior to being visually inspected by this process and rather are inspected by ISC (Inspection Sample Control) personnel. The samples undergoing destructive particles testing are not fully representative of routine production.

    Contains “visually inspect*”Read the Form 483 →

  17. Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 12

    … The verification of method AM-(b)(4) 100-018 Supplemental Destructive Visual Inspection for Visible Particulates of Client (b)(4) Drug Product Samples, v1, on 7/12/22, demonstrated the analyst could execute the method. The verification did not show the method or the analyst's ability to detect particles. B. A-SOP-09-01-061, (b)(4) Inspection of Media Filled Vials, v9, dated 12/13/21 states to (b)(4) (b)(4) the containers for approximately (b)(4) …

    Contains “visual inspection*”Read the Form 483 →

  18. ID Biomedical Corporation of QuebecInspection ended May 20, 2022 · FEI 3004835647 · Observation 4

    Preventative maintenance activities were incomplete. Specifically, the (b)(4) in the (b)(4) on the (b)(4) are not part of a routine preventative maintenance program to include visual inspection. These (b)(4) (b)(4) are used during [illegible]

    Contains “visual inspection*”Read the Form 483 →

  19. Engage Uni LLCInspection ended Nov 12, 2021 · FEI 3016249968 · Observation 1

    … Additionally, your firm did not document Deviation PD01184, which initiated a change in the visual inspection procedure of implants, in the DHR reviews conducted for Lots (b) (4) and (b) (4) of (b) (4), Part No. (b) (4) This deviation was included in the manufacturing records provided by your firm's cleaning, packaging, and sterilization supplier, which were subject to DHR review.

    Contains “visual inspection*”Read the Form 483 →

  20. Dr. Reddy's Laboratories Ltd.Inspection ended Oct 29, 2021 · FEI 3006549835 · Observation 1

    … For example, 1) Incident 200374932 for major with in- The handling of incidents proc On 06/23/2021, the visual inspection for inspection conducted was observed. Incident 200374932 states that due to black particles was trending particles was approximately ~ The initiation date for Incident critical and major visual inspection incident number (200374932). The reports w The SAP system does not include 2) The ma=i~.i~~ ~£.i~b.;rmacopoe 11 1 for the …

    Contains “visual inspection*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about visual inspection in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.