Visual inspection and particulates in FDA Form 483 observations
Inspecting filled product for defects and visible particles, and investigating the particles and foreign matter found. FDAgent finds 143 such observations in 91 Form 483s issued to 88 facilities, for inspections that ended between June 2012 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 143
- Each quoted below
- Form 483s
- 91
- Posted by FDA
- Facilities
- 88
- Distinct FEIs
- Most recent
- Sep 10, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 46 in 2026
| Year | Observations |
|---|---|
| 2012 | 1 |
| 2013 | 2 |
| 2014 | 0 |
| 2015 | 0 |
| 2016 | 8 |
| 2017 | 11 |
| 2018 | 6 |
| 2019 | 10 |
| 2020 | 1 |
| 2021 | 6 |
| 2022 | 9 |
| 2023 | 17 |
| 2024 | 8 |
| 2025 | 18 |
| 2026 | 46 |
How FDAgent sorts observations into this theme
One fixed rule, applied by code to every observation FDAgent can quote. No model and no similarity score decides.
Its text contains one of these phrases
“visual inspection*” · “visually inspect*” · “visible particle*” · “visible particulate*” · “particulate matter” · “foreign matter” · “foreign particle*” · “foreign material*” · “AQL”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 143 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Dr. Reddy's Laboratories Ltd.Inspection ended Oct 29, 2021 · FEI 3006549835 · Observation 2
… The particulate matter visible and subvisible procedure makes reference to USP <771> for no method description (i.e. instructions). Incident 2003656855 is for the abnormal obscuration for particle size greater than specification. articles per ml. The measurement D. The related substances test method deviation of mli6 for system suitability method validation was conducted at justification provided for the change. The Analytical method validation …
Contains “particulate matter”Read the Form 483 →
Dr. Reddy's Laboratories Ltd.Inspection ended Oct 29, 2021 · FEI 3006549835 · Observation 6
The accuracy, specificity and reproducibility Specifically, not all the drug substance and drug documented. For example, C) verification, validation, or transfer include a. Viscosity Profile (As a function of - b. Particulate matter for sub-visible D) Spectroscopic identification test has not been verified for -
Contains “particulate matter”Read the Form 483 →
Wuxi BiologicsInspection ended Apr 2, 2021 · FEI 3010606982 · Observation 6
… However, no scientific rationale was provided to justify the visual inspection of only 11 of the (b) retention sample vials. In addition, SOP WX-SOP-00425, entitled Product Complaints, section 4.4.1.3, states to review retention samples and does not provide instructions for reviewing reduced amounts.
Contains “visual inspection*”Read the Form 483 →
Imprimis NJOF, -LLCInspection ended Jan 29, 2021 · FEI 3013024146 · Observation 1
… lot #(b) (4) it was discovered that the product lot was released for commercial distribution despite multiple failures in routine production in-process and AQL quality checks. Out of (b) (4) boxes ((b) (4) vials) manufactured, (b) (4) boxes ((b) (4) vials) were released into commercial distribution. The summary of the repeated production in-process and AQL quality checks are as follows: Batch Record Package Page Numbers 71, 72 Inspected by …
Contains “AQL”Read the Form 483 →
OSO BioPharmaceuticals Manufacturing, LLCInspection ended Mar 20, 2020 · FEI 1643045 · Observation 2
… in Filling Room f<-'J_Deviation Report spider in Filling Room >I 4 •Deviation 14979 created of Filling Room >nlI_ b) When particles are found during 100% visual inspection processes for parenteral drugs investigations are not opened to determine root cause and implement corrective and preventative actions to ensure that operations that generate inclusion of visible particles are prevented. For example, the visual inspection from lot (D) (4) …
Contains “visual inspection*”Read the Form 483 →
SCA Pharmaceuticals, Inc.Inspection ended Nov 7, 2019 · FEI 3010683157 · Observation 2
… In addition, your complaint procedure does not specifically include directions when a reserve/retain sample will be tested or visually inspected as part of the complaint investigation as evidenced by CUS 19-020-LR, CUS 19-058-LR, CUS 10-059-LR, CUS 19-060-LR, CUS 19-069-LR, CUS 19-079-LR, and CUS 19-094-LR.
Contains “visually inspect*”Read the Form 483 →
SCA Pharmaceuticals, Inc.Inspection ended Nov 7, 2019 · FEI 3010683157 · Observation 4
The results of the examination of the packaged and labeled products were not documented in the batch production or control records. Specifically, I observed during the visual inspection by employees rejects from the 100% and the AQL were placed in the same bin, thus not allowing for accurate data to be entered in the batch records to determine if both passed your specification for visual inspection as defined in SOP COM-013-LR. For the AQL, …
Contains “visual inspection*”Read the Form 483 →
Ajinomoto Althea, Inc.Inspection ended Aug 7, 2019 · FEI 3004575449 · Observation 1
… Injectable drug product lots produced from on or about January - February 2018 were investigated due to a higher incidence of particulate rejects found during visual inspection. The firm's investigation into these particulates ultimately determined the root cause to be associated with corroded (D)-(4) within connectors used to connect the (D)-(4) drug product vessel to the (D)-(4) set up and/or filling line. Drug product lots produced during this …
Contains “visual inspection*”Read the Form 483 →
Hieber’s PharmacyInspection ended Jul 17, 2019 · FEI 1000121499 · Observation 1
… Instead personnel perform a (b) (4) visual inspection of the pressures on the (b)(4) and the clean room gauge, and record the pressures on the Cleaning and Calibration Log. Additionally, there is no pressure gauge to monitor the pressure or pressure differential between the ISO 7 clean room and the uncontrolled environment in the vestibule. This is a repeat observation from the 2017 inspection.
Contains “visual inspection*”Read the Form 483 →
Dr. Reddy's Laboratories Ltd.Inspection ended Jun 21, 2019 · FEI 3006549835 · Observation 2
The device design was not correctly translated into production specifications. Specifically, your Acceptance Quality Limit [AQL] does not take into account the component critical dimensions specification during receipt of components for the manufacture of Injection ©@ ho @nL such as®® and stoppers.
Contains “AQL”Read the Form 483 →
Baxalta Belgium Manufacturing S.A.Inspection ended May 31, 2019 · FEI 3002806503 · Observation 2
… Since early 2019, an increased level of visible (b) (4) was observed again during the (b) (4) visual inspection for Gammagard Liquid and HyQvia lots manufactured using (b) (4) from the (b) (4). The (b) (4) were identified as (b) (4) A possible root cause was determined to be related to the implementation of the (b) (4) configuration. As a preventive action, the (b) (4) was replaced by the (b) (4) (b) (4) for manufacture of Gammagard Liquid and …
Contains “visual inspection*”Read the Form 483 →
Baxalta Belgium Manufacturing S.A.Inspection ended May 31, 2019 · FEI 3002806503 · Observation 5
… during production, product release testing results (including sterility), environmental and bioburden testing results, pre and post filter integrity results, visual inspection of retention samples (where applicable), stability review, and NAT/PCR and/or serology testing.
Contains “visual inspection*”Read the Form 483 →
Triangle Compounding Pharmacy IncInspection ended Apr 4, 2019 · FEI 3004969894 · Observation 1
Drug product has been prepared using a method of manufacture that does not assure it meets requirements as to the safety, identity, strength, quality, and/or purity characteristics which it is purported to possess. Specifically, up to an average of approximately 10.9% of some product lots compounded in vials supplied by your firm's chosen supplier, contained foreign matter (classified by your firm as light particles, dark particles, fibers, etc.) …
Contains “foreign matter”Read the Form 483 →
Front Door Pharmacy, LLC dba Pure PharmacyInspection ended Mar 18, 2019 · FEI 3012937475 · Observation 11
The ISO-classified areas have difficult-to-clean, particle-generating surfaces. Specifically, during a walk-through on 2/25/2019, foreign particulate matter was observed on top of [redacted] which was not in service. Foreign particulate matter was observed in the ISO 7 production area adjacent to the ISO 5 hood. The firm failed to prevent particle generation or provide adequate cleaning for visibly dirty equipment or surfaces.
Contains “particulate matter”Read the Form 483 →
Lupin LimitedInspection ended Feb 8, 2019 · FEI 3004819820 · Observation 1
… spots were observed over the finished drug product during the AQL check performed ®?® manual inspection. Based on the finding, the batch was manually inspected again, and all together separated 224951 defective tablets out of © tablets. The batch yield inclusive of manufacturing loss (276) did not meet the batch record specification limit of RE: to! %. Your investigation concluded that the LED spots were possibly from thel®@ due to improper ®) ©) …
Contains “AQL”Read the Form 483 →
Cipla LimitedInspection ended Sep 28, 2018 · FEI 3004081307 · Observation 2
Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up. Specifically, A change to production instructions was implemented prior to completion of all corrective action changes related with a deviation. Namely, as part of Deviation DEV-1006-2017-00073 for [illegible] Tablets, USP [illegible] mg lot [illegible] (AQL non-compliance for minor defects). A Remedial Action item was initiated …
Contains “AQL”Read the Form 483 →
New Vitalis Pharmacy LLC dba New Vitalis PharmacyInspection ended Sep 7, 2018 · FEI 3014391500 · Observation 2
Visual inspection of finished drug products prior to distribution is not adequately performed. Specifically, Your firm sterilized Testosterone Cypionate 200 MG/ML in Grapeseed Oil injectable lots AL-07192018@906 and AL-08072018@901 at [illegible] for [illegible] minutes, respectively on 07/24/18 and 08/07/18. Your firm stated that 100% visual checks are performed on each lot prior to labeling and dispensing or distribution to your patient. …
Contains “visual inspection*”Read the Form 483 →
Celltrion Inc.Inspection ended Jul 17, 2018 · FEI 3005241015 · Observation 2
Employees engaged in the processing of a drug product lack the training required to perform their assigned functions. Specifically, Your firm performs 100% visual inspection on finished drug product. Your qualification for the operators is inadequate in that the qualification vials with glass particles are on the [illegible] of the [illegible] do not the [illegible] at the [illegible] of the vial. Your firm only utilizes photographs for training …
Contains “visual inspection*”Read the Form 483 →
Aurobindo Pharma Ltd.Inspection ended Feb 20, 2018 · FEI 3008461619 · Observation 4
… collection vials for visual inspection. To reach this room personnel B ®@ should pass)’ sets of doors ©) 0) - - — ]. This room is two sets of doors away from the grade “B” and grade “A” areas where the filling and activities for ®@ injection takes place.
Contains “visual inspection*”Read the Form 483 →
Aurobindo Pharma Ltd.Inspection ended Feb 20, 2018 · FEI 3008461619 · Observation 7
The statistical quality control criteria fail to include appropriate acceptance levels and rejection levels. Specifically, your procedure for receiving and inspection of the components and packaging materials (procedure # FU4-QC-GEN-026, Sampling of packing materials) follows an unspecified level of AQL of ANSI Z1.4-2008 with no clear criteria for acceptance and rejection level. This procedure is deficient to provide clear reject and acceptance …
Contains “AQL”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.192Production record review16
- 21 CFR 211.100Written procedures; deviations12
- 21 CFR 211.113Control of microbiological contamination9
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.25Personnel qualifications6
- 21 CFR 211.160General requirements6
- 21 CFR 211.110Sampling and testing of in-process materials and drug products3
- 21 CFR 211.165Testing and release for distribution3
- 21 CFR 211.63Equipment design, size, and location2
- 21 CFR 211.67Equipment cleaning and maintenance2
Ask FDAgent about visual inspection in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.