Visual inspection and particulates in FDA Form 483 observations

Inspecting filled product for defects and visible particles, and investigating the particles and foreign matter found. FDAgent finds 143 such observations in 91 Form 483s issued to 88 facilities, for inspections that ended between June 2012 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
143
Each quoted below
Form 483s
91
Posted by FDA
Facilities
88
Distinct FEIs
Most recent
Sep 10, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 46 in 2026

Visual inspection observations in Form 483s by inspection year
YearObservations
20121
20132
20140
20150
20168
201711
20186
201910
20201
20216
20229
202317
20248
202518
202646

How FDAgent sorts observations into this theme

One fixed rule, applied by code to every observation FDAgent can quote. No model and no similarity score decides.

Its text contains one of these phrases

“visual inspection*” · “visually inspect*” · “visible particle*” · “visible particulate*” · “particulate matter” · “foreign matter” · “foreign particle*” · “foreign material*” · “AQL”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 143 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. GlaxoSmithKline Biologicals Kft.Inspection ended Jan 31, 2025 · FEI 3008322822 · Observation 2

    Procedures for the acceptance and rejection of components and materials utilized within drug substance manufacturing are not adequate. Procedure LSOP 9000087267 (ver. 01 – approved 20MAR2024), titled "FILT.UF (b)(4)" was implemented as a corrective action in response to deviation 201042740 and prior to use within manufacturing. The procedure requires visual inspection of the (b)(4). The procedure allows for the acceptance and use of (b)(4) …

    Contains “visual inspection*”Read the Form 483 →

  2. Zhejiang Huahai Pharmaceutical Co., Ltd.Inspection ended Jan 24, 2025 · FEI 3003999190 · Observation 1

    … On the morning of January 16, 2025, a production operator had visually inspected the equipment for cleanliness and approved the cleaning without identifying any 4 (b)( esidues. When the equipment was inspected later in the morning, after initial (bff4J or batch ~ had already .._____ ----- started, visible residues were observed in the following locations: (bT(i i..______ (b residues were observed in the l ive of the uct. Swab _____________.. …

    Contains “visually inspect*”Read the Form 483 →

  3. Zhejiang Huahai Pharmaceutical Co., Ltd.Inspection ended Jan 24, 2025 · FEI 3003999190 · Observation 3

    OBSERVATION #3 There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. 1. The visual inspection qualification process for 100% manual visual inspection is deficient in the following ways: a. The visual inspection kits for liquid vials do not contain glass, metal, elastomer material, and fiber of known …

    Contains “visual inspection*”Read the Form 483 →

  4. Zhejiang Huahai Pharmaceutical Co., Ltd.Inspection ended Jan 24, 2025 · FEI 3003999190 · Observation 4

    OBSERVATION #4 There is a failure to thoroughly review any unexplained discrepancy or the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. 1. Deviation DF-23012 was opened when foreign matter was observed d.m_____(bTI of batch (bH f (bf~ able g (US Market). The batch was rejected. The investigation failed to perform any identification of the foreign matter or take …

    Contains “foreign matter”Read the Form 483 →

  5. Staska Pharmaceuticals IncInspection ended Sep 18, 2024 · FEI 3017473850 · Observation 1

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, During your firm's visual inspection of Buffered Lidocaine HCl USP 2% 20mg/mL, 50mL Vials for injection Lot (b) (4) MFG 08/30/2022, (b) (4) vials were rejected due to defects including particles, package defects, sealing …

    Contains “visual inspection*”Read the Form 483 →

  6. Staska Pharmaceuticals IncInspection ended Sep 18, 2024 · FEI 3017473850 · Observation 2

    Your firm failed to establish acceptance criteria for the sampling and testing conducted by the quality control unit that are adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release. Specifically, In regards to your 100% visual inspection of finished product vials and syringes: Your firm has not implemented a clear …

    Contains “visual inspection*”Read the Form 483 →

  7. Staska Pharmaceuticals IncInspection ended Sep 18, 2024 · FEI 3017473850 · Observation 3

    … specific defect locations on containers, and where feasible, photographs of the defects to ensure consistency in defect identification during qualification visual inspections. B. Your firm has not incorporated defect types routinely encountered during production into the training program. The absence of naturally occurring defects or production rejects in inspector training can limit an inspector's ability to detect actual production-related …

    Contains “visual inspection*”Read the Form 483 →

  8. Nubratori, IncInspection ended Jul 26, 2024 · FEI 3010166491 · Observation 4

    Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release. Specifically, Your firm's visual inspection program is inadequate. a. You do not document the complete results [illegible] Quality control after the 100% visual inspection …

    Contains “visual inspection*”Read the Form 483 →

  9. Divi's Laboratories Ltd. (Unit II)Inspection ended Jul 19, 2024 · FEI 3004149463 · Observation 1

    Written procedures are not established for the cleaning of equipment used in the manufacture of (b)(4) API. Specifically, SOP "CLEANING PROCEDURES", SOP NO: PD/OP/0017, REV NO: 000, EFFECTIVE DATE: 01/01/2021, does not include provisions to clean or visually inspect the area (b)(4) (b)(4) (b)(4) behind the (b)(4) of (b)(4) are used in the manufacture of (b)(4)

    Contains “visually inspect*”Read the Form 483 →

  10. Serum Institute of India Pvt. Limited Manjari SiteInspection ended Jul 2, 2024 · FEI 3020223359 · Observation 5

    DEV-003-2024-0049 detected on January 29, 2024 indicated a critical defect, (b) (4) (b) (4) was observed during AQL of (b) (4), batch (b) (4). Your firm failed to fully investigate and implement an effective corrective action/preventative action after identifying (b) (4) of (b) (4) for (b) (4) contributed to this critical defect.

    Contains “AQL”Read the Form 483 →

  11. Fukuzyu Pharmaceutical Co., Ltd.Inspection ended Jan 19, 2024 · FEI 3002807025 · Observation 2

    … The [illegible] equipment was estimated clean after cleaning verification with rinse samples, swab samples, and visual inspection was complete. These are the processing steps before filling and packaging. Equipment use logs indicate your firm used this equipment to manufacture API and other hazardous and non-hazardous substances. y-c API include batch (b)(4) lot (b)(4), batch (b)(4) lot (b)(4), batch (b)(4) lot (b)(4). B) Your cleaning procedures …

    Contains “visual inspection*”Read the Form 483 →

  12. Jiangsu Hengrui Pharmceuticals Co., LtdInspection ended Jan 16, 2024 · FEI 3007373503 · Observation 4

    … C) Official eye exam results from medical professionals for visual inspection operators are not reviewed and managed by the Quality Unit. D) Parenteral drug products awaiting destruction in your waste area are not secure. During our walkthrough on 01/08/2024 we observed (b)(4) doors to your waste building open and no personnel present. This building is located directly across a public sidewalk and public street with an approximate 3.5-foot fence. …

    Contains “visual inspection*”Read the Form 483 →

  13. Laurus Synthesis Private LimitedInspection ended Dec 12, 2023 · FEI 3011524794 · Observation 1

    … The complete bulk lot was not visually inspected for particles and there was no scientific rationale for taking (b) (4) g of sample from a (b) (4) bulk batch for screening for (b) (4) particles. The key starting material (b) (4) is used in the manufacture of API (b) (4) intended for the US and Global markets. 3) Deviation investigation DEV-SV1-23-0002 was initiated on January 07, 2023 to investigate damage of the (b) (4) (b) (4) on the (b) (4) …

    Contains “visually inspect*”Read the Form 483 →

  14. Titan Kogyo, LtdInspection ended Dec 8, 2023 · FEI 3009155994 · Observation 3

    … following: specific gravity, (b) (4) The (b) (4) lot# (b) (4) COA from (b) (4) lists the following analyses: purity, ignition on residue, moisture, (b) (4) foreign matter. The firm's verification testing of the aforementioned supplier COA only included the following: purity and ignition on residue. The (b) (4) lot (b) (4) COA from (b) (4) lists the following analyses: (b) (4) concentration, (b) (4) specific gravity, (b) (4) and viscosity. The …

    Contains “foreign matter”Read the Form 483 →

  15. Catalent Indiana, LLCInspection ended Nov 15, 2023 · FEI 3005949964 · Observation 1

    … of pharmaceutical products were performed by appropriately qualified production personnel (namely, qualification of personnel performing manual visual inspection) (§7.5.1); and • Did not always ensure that "all equipment used in the manufacturing, processing, packaging, or holding of Drug Substance, Drug Product, or Medical Devices is maintained in a good state of repair" (§6.3.2.2).

    Contains “visual inspection*”Read the Form 483 →

  16. Catalent Indiana, LLCInspection ended Nov 15, 2023 · FEI 3005949964 · Observation 4

    Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in process material and the drug product. Specifically, For visual inspection of drug products and biological drug products purporting to be sterile, operators are qualified on Kt>) (4I vials; doing so allows operators to inspect [6) (4) I, and t>f …

    Contains “visual inspection*”Read the Form 483 →

  17. Catalent Indiana, LLCInspection ended Nov 15, 2023 · FEI 3005949964 · Observation 6

    … 1004053 were opened on 26 OCT 2023 and 27 OCT 2023, respectively, pertaining to incidences of the [(t> -(4) ] malfunctioning on System [(o)e(4 (Syringe) (4) Visual Inspection) in Building D, Room 141, used for visual inspection of Project Code ff<lL Pre-Filled Syringes. Both WOs failed to contain any information documenting the incidences nor log statements as required by the written procedure, A-SOP-07-01-015: Performing Maintenance and …

    Contains “visual inspection*”Read the Form 483 →

  18. Sanofi PasteurInspection ended Sep 29, 2023 · FEI 3002972083 · Observation 2

    Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up. Specifically, A. Deviation record MLED22E3775 dated August 1, 2022, documents that two vials of (b)(4) (US Market) [illegible] were observed to contain cellulose particles during visual inspection of retain samples related to a complaint of vial breakage …

    Contains “visual inspection*”Read the Form 483 →

  19. Wickliffe LLCInspection ended Sep 15, 2023 · FEI 3002992930 · Observation 2

    … 3) Visual inspection limits are not based on defect criticality. An overarching (b) (4) reject threshold is set for all sterile injectable batches with no consideration for defect types that would impact sterility such as turbidity, container integrity, and extrinsic particulates, such as hair. Defect criticality has not been determined and defects found are not recorded during visual inspection. Additionally, the visual inspectors are not …

    Contains “visual inspection*”Read the Form 483 →

  20. Wickliffe LLCInspection ended Sep 15, 2023 · FEI 3002992930 · Observation 5

    Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product or other drug products that may have been associated with the specific failure or discrepancy, Specifically, 1) Your firm did not determine a root cause or investigate batches that failed during visual inspection for leaking vials due to excessive seals popping off during (b) (4) sterilization. …

    Contains “visual inspection*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about visual inspection in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.