Visual inspection and particulates in FDA Form 483 observations
Inspecting filled product for defects and visible particles, and investigating the particles and foreign matter found. FDAgent finds 143 such observations in 91 Form 483s issued to 88 facilities, for inspections that ended between June 2012 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 143
- Each quoted below
- Form 483s
- 91
- Posted by FDA
- Facilities
- 88
- Distinct FEIs
- Most recent
- Sep 10, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 46 in 2026
| Year | Observations |
|---|---|
| 2012 | 1 |
| 2013 | 2 |
| 2014 | 0 |
| 2015 | 0 |
| 2016 | 8 |
| 2017 | 11 |
| 2018 | 6 |
| 2019 | 10 |
| 2020 | 1 |
| 2021 | 6 |
| 2022 | 9 |
| 2023 | 17 |
| 2024 | 8 |
| 2025 | 18 |
| 2026 | 46 |
How FDAgent sorts observations into this theme
One fixed rule, applied by code to every observation FDAgent can quote. No model and no similarity score decides.
Its text contains one of these phrases
“visual inspection*” · “visually inspect*” · “visible particle*” · “visible particulate*” · “particulate matter” · “foreign matter” · “foreign particle*” · “foreign material*” · “AQL”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 143 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Centrient Pharmaceuticals India Private LimitedInspection ended Jan 27, 2026 · FEI 3004497364 · Observation 2
Failure of production operations to prevent contamination of intermediate and API by other materials. Specifically, A. Your firm utilizes (b)(4) 101, for the manufacturing of (b)(4) During the walkthrough inspection on 19-Jan-2026, we observed several (b)(4) pieces inside the (b)(4) floating foreign materials that appeared to be (b)(4) water ready for the next batch, with visible observation, (b)(4) 101 contained (b)(4) in (b)(4) (b)(4) …
Contains “foreign material*”Read the Form 483 →
Shimoga ChemicalsInspection ended Jan 23, 2026 · FEI 3033881432 · Observation 4
… During the inspection on January 19, 2026, we observed a (b)(4) identified as cleaned; however, black foreign matter was observed inside the (b)(4) and residual (b)(4) was observed in the (b)(4). B. Your firm failed to establish adequate procedures for monitoring and controlling your water system, which consists solely of (b)(4) water used only for equipment cleaning. On January 19, 2026, the (b)(4) water sampling point was observed to be rusted …
Contains “foreign matter”Read the Form 483 →
Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 2
… QE-163002 (initiated May 9, 2025): Cancelled as "raised in error" for incorrect defect type entry "foreign matter on body" in EBR defect log. QE-152679 (initiated July 1, 2025): Cancelled for missing logbook entries based on "presence of a second GMP source". QE-134066 (initiated March 27, 2025): Cancelled for incorrect (b) (4) confirmed from original GMP source with manufacturing and QA agreement. QE-094631 (initiated November 17, 2024): …
Contains “foreign matter”Read the Form 483 →
Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 3
… (b) (4) particulate matter consistent with (b) (4) was observed on the Grade (b) (4) floor, and localized areas accumulated significant (b) (4) residue. Batch (b) (4) of Myozyme was being filled when this observation was made. C) During the inspectional walkthrough on January 13, 2026, we observed a section in the Grade (b) (4) Filling Line (b) (4) (Room (b) (4)) where a portion of the (b) (4) had been removed. The floor in this area exhibited …
Contains “particulate matter”Read the Form 483 →
Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 5
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A) Complaint 493112 pertaining to "Foreign Matter After Reconstitution" found in Thymoglobulin lot (b) (4) described brown particulate or blemish on the inside of the vial that was removable when wiped with a cloth. The …
Contains “foreign matter”Read the Form 483 →
US Specialty Formulations LLCInspection ended Jan 14, 2026 · FEI 3010680515 · Observation 4
Procedures designed to prevent microbiological contamination are not established and followed. Specifically, (A) On January 5, 2026, we observed QC Lab Technician g/mL for Injection after the Production Team had completed 100% visual inspection According to Section 4.3.1.1 of QC-0003, Visual Inspection Program, vials are labeled. We observed QC Lab Technician ~ particulate. We also observed the QC Lab referenced vials to adequately assess fill …
Contains “visual inspection*”Read the Form 483 →
Wizcure Pharmaa Private LimitedInspection ended Dec 10, 2025 · FEI 3030304532 · Observation 6
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. A. You do not perform visual inspection of your aseptically filled product, and you have not established written procedures regarding this critical process. Your QA Manager reported you inspect the outside of each unit for …
Contains “visual inspection*”Read the Form 483 →
UBI Pharma Inc.Inspection ended Oct 14, 2025 · FEI 3004713402 · Observation 1
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its [illegible]. Specifically, the visual inspection of your vials is carried out in [illegible] then undergo Acceptance Quality Limit (AQL) testing before releasing. You (6)(4) R eVI (b)(4) 41 confirmed that the [illegible] was not qualified (6)(4) mcg/mL ~~ mL and ~~ mL vials. The qualification is based on …
Contains “visual inspection*”Read the Form 483 →
UBI Pharma Inc.Inspection ended Oct 14, 2025 · FEI 3004713402 · Observation 2
Control procedures are not established which [illegible] manufacturing processes that may be responsible for causing [illegible] process material and the drug product. Specifically, your procedures SOP No. P3190 [illegible] Procedure of (6)(4) Version 15 Sterile (b)(4) Liquid Vial Inspect; P801 Version 5 Sampling Plan and AQL Calculation (Effective date 3/10 [illegible]) sterile (b)(4) products are essentially free [illegible]. A. E.g., for the …
Contains “AQL”Read the Form 483 →
UBI Pharma Inc.Inspection ended Oct 14, 2025 · FEI 3004713402 · Observation 5
… Visual inspection reports for the three implicated batches confirmed presence [illegible] underfill vials: 1 (6)(4) Batch No.1 (6)(4) [illegible]. Your batch record suggested that you sample [illegible] filling rate of [illegible].
Contains “visual inspection*”Read the Form 483 →
Farmakeio Outsourcing LLCInspection ended Sep 5, 2025 · FEI 3014982757 · Observation 1
… The [(D)(4)] intermediate product, which is (b)(4) and then processed into pellets, was visually inspected, packaged, [(6)(4)] sterilized, and distributed without this critical check. B. Your firm failed to adequately investigate received customer complaints. For example: 1. COMP-2025-0023 dated 6/20/2025 and COMP-2025-0018 dated 5/23/2025, documents received complaints for cracked pellets. Your firm's failed to adequately investigate the source …
Contains “visually inspect*”Read the Form 483 →
Farmakeio Outsourcing LLCInspection ended Sep 5, 2025 · FEI 3014982757 · Observation 2
… Your firm failed to comply with USP <790>, which allows AQL, as a sampling requirement at batch release to be conducted "After 100% Manufacturing Inspection."
Contains “AQL”Read the Form 483 →
Farmakeio Outsourcing LLCInspection ended Sep 5, 2025 · FEI 3014982757 · Observation 4
… During a review of your firm initiated CAPA-2025-002, Finding foreign material - granulation process, your firm documented the root cause for the origin of the foreign material resulted from the granulator impeller shaft grinding against the [(b)(4)]. A preventive maintenance (PM) was added for the [(b)(4)] - Lab Grinder to include an inspection the [(b)(4)] before running the granulator. Your firm failed to include in the PM an inspection of the …
Contains “foreign material*”Read the Form 483 →
Hikma Injectables USA Inc.Inspection ended Aug 8, 2025 · FEI 3022897129 · Observation 1
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, Your firm's procedure, Standard Operating Procedure SOPDTN15125, "100% Visual Inspection of Compounded Sterile Products," Revision 3.0, effective December 30, 2024, establishes [illegible]% reject rate …
Contains “visual inspection*”Read the Form 483 →
Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 6
Written records of investigations into the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up. Specifically, particulate matter on 5/20/2025 in approximately [illegible] syringes which were a part of your media fill lot [illegible]. These syringes were previously inspected by your [illegible] on 5/07/2025 and 5/15/2025 and were not identified with particulate matter. B. You …
Contains “particulate matter”Read the Form 483 →
Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 8
Written procedures are not established, written and followed that describe the in-process controls, tests and examinations to be conducted on appropriate samples of in-process materials of each batch. Specifically, A. You lack establishment of scientifically justifiable in-process limits regarding visual inspection. Your limit is Vo, in aggregate for your 100% inspection in addition to your post 100% inspection sample(s). You have not established …
Contains “visual inspection*”Read the Form 483 →
Medi-Fare Drug Pharmaceutical Compounding LLCInspection ended Jun 6, 2025 · FEI 3009925820 · Observation 9
Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions. A. Your visual inspection qualification training is inadequate regarding both your initial qualification and your lack of requalification. 1. You lack an annual requalification process. 2. Your initial qualification is not scientifically established nor standardized. Your initial visual inspection qualification is …
Contains “visual inspection*”Read the Form 483 →
Jiangsu Hengrui Pharmaceuticals Co., LtdInspection ended Apr 4, 2025 · FEI 3011603969 · Observation 1
Written procedures are not established for evaluations done at least annually and including provisions for a review of investigations conducted for each drug product. Specifically, Your firm's annual product review is not sufficient in trending to decrease Visible Particulates in Sterile (b) (4) Injection. Your firm released the following batches of Sterile (b) (4) Injection to the United States: Product Sterile (b) (4) Injection, USP, (b) (4) mg …
Contains “visible particulate*”Read the Form 483 →
Piramal, Piramal Pharma LimitedInspection ended Feb 17, 2025 · FEI 3008763768 · Observation 3
OBSERVATION 3 Written records of investigation of an API complaint do not include adequate follow-up. Specifically, Customer Complaint CC-22-06 was initiated on May 21, 2022, for foreign particles being observed for [illegible] Batch No. [illegible], Retest Date: May 2024. Samples from another API batch, Batch No. (b)(4), was used to test traces of potential foreign/metallic particles. However, there was no documented attempt to retrieve and test …
Contains “foreign particle*”Read the Form 483 →
Piramal, Piramal Pharma LimitedInspection ended Feb 17, 2025 · FEI 3008763768 · Observation 6
… On February 11th, 2025, I observed (b)(4) foreign matter within the (b)(4) API Batch No. held within (b)(4) vessel (b)(4). During the inspection, the matter was isolated from the (b)(4) and sent for external laboratory testing. The identification testing demonstrated that the foreign matter originated from the [illegible] use processing activities.
Contains “foreign matter”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.192Production record review16
- 21 CFR 211.100Written procedures; deviations12
- 21 CFR 211.113Control of microbiological contamination9
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.25Personnel qualifications6
- 21 CFR 211.160General requirements6
- 21 CFR 211.110Sampling and testing of in-process materials and drug products3
- 21 CFR 211.165Testing and release for distribution3
- 21 CFR 211.63Equipment design, size, and location2
- 21 CFR 211.67Equipment cleaning and maintenance2
Ask FDAgent about visual inspection in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.