Skip to content

Visual inspection and particulates in FDA Form 483 observations

Inspecting filled product for defects and visible particles, and investigating the particles and foreign matter found. FDAgent finds 143 such observations in 91 Form 483s issued to 88 facilities, for inspections that ended between June 2012 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
143
Each quoted below
Form 483s
91
Posted by FDA
Facilities
88
Distinct FEIs
Most recent
Sep 10, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 46 in 2026

Visual inspection observations in Form 483s by inspection year
YearObservations
20121
20132
20140
20150
20168
201711
20186
201910
20201
20216
20229
202317
20248
202518
202646

How FDAgent sorts observations into this theme

One fixed rule, applied by code to every observation FDAgent can quote. No model and no similarity score decides.

Its text contains one of these phrases

“visual inspection*” · “visually inspect*” · “visible particle*” · “visible particulate*” · “particulate matter” · “foreign matter” · “foreign particle*” · “foreign material*” · “AQL”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 143 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Shanghai Henlius Biopharmaceutical Co., Ltd.Inspection ended May 20, 2026 · FEI 3016529861 · Observation 4

    … Your firm's (b)(4) cleaning validation for (b)(4) and (b)(4) used in the manufacture of (b)(4) drug substance did not include swab sampling or visual inspection of the internal product-contact surfaces of the (b)(4). Your cleaning validation sampling plan did not provide adequate scientific justification demonstrating that rinse samples were representative of the most difficult to clean locations within the (b)(4). b. Your firm did not perform …

    Contains “visual inspection*”Read the Form 483 →

  2. Fresenius Kabi USA, LLCInspection ended May 14, 2026 · FEI 3001833549 · Observation 1

    Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, in 2024 your firm conducted studies to qualify the defect standards for your visible particulate container challenge [illegible]. However, you failed to assess the appropriateness of your current (b) …

    Contains “visible particulate*”Read the Form 483 →

  3. Fresenius Kabi USA, LLCInspection ended May 14, 2026 · FEI 3001833549 · Observation 2

    … Of the (b) (4) defect units, [illegible] contain foreign material particulates of the following types and sizes: (b) (4). Your threshold study established a PoD of [illegible] (b) (4)% for (b) (4) ((b) (4) stopper) particulates; however, defects at this size are not represented in Test (b) (4) and (B) [illegible] for airflow visualization (C) Your firm uses fog generated from (b) (4) studies in cleanrooms, including sterile drug product filling …

    Contains “foreign material*”Read the Form 483 →

  4. Jiangsu Hansoh Pharmaceutical Group Co Ltd.Inspection ended Apr 24, 2026 · FEI 3008316144 · Observation 3

    … The firm's visual inspection qualification program is inadequate to demonstrate that inspectors can reliably detect all defect types in sterile injectable products. 1. Your visual inspection qualification program lacks adequate Quality Unit over-site and control. Production personnel maintain qualification kits, administer qualification tests, make pass/fail determination with only a Quality review of the bottle condition. This arrangement fails …

    Contains “visual inspection*”Read the Form 483 →

  5. USV Private LimitedInspection ended Apr 17, 2026 · FEI 3004086192 · Observation 4

    Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. Specifically, your visual inspection process for sterile products is inadequate: A. Your firm manufactures sterile injectable products including (b) (4) (b) (4) Injection. Review of your visual inspection …

    Contains “visual inspection*”Read the Form 483 →

  6. Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 2

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. A. Visual Inspection 1. Your firm uses only one defect kit for operator training, ongoing requalification, and performance testing. This kit contains only one example of each defect type. Some of the defects have been in use for over four years, allowing operators to repeatedly view, and are tested on identical defects …

    Contains “visual inspection*”Read the Form 483 →

  7. AstraZeneca ABInspection ended Apr 10, 2026 · FEI 3003342394 · Observation 1

    There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, Your firm's investigations of deviations are not always adequate. a. Quality Event QE-239020 was initiated 16NOV2025 following the identification of foreign particles [illegible] tablets. Analytical characterization identified the particles as containing [illegible] [illegible] batches of [illegible] [illegible] …

    Contains “foreign particle*”Read the Form 483 →

  8. AstraZeneca ABInspection ended Apr 10, 2026 · FEI 3003342394 · Observation 2

    … tablets, EXP: [illegible], manufactured from [illegible] through [illegible], in-process appearance testing revealed four tablets containing foreign particulate matter. This was from the inspection of [illegible] tablets. Quality Event QE-239020 was initiated 16NOV2025, and your investigation attributed the defect to a worn tablet press. However, the preventative maintenance program was not updated to address the equipment wear condition that …

    Contains “particulate matter”Read the Form 483 →

  9. Dendreon Pharmaceuticals LLCInspection ended Mar 25, 2026 · FEI 3008821247 · Observation 1

    … nonconformities, your firm failed to thoroughly investigate the following: a) Non-conformance NC-2025-0053, initiated on May 23, 2025, investigated the visual inspection failure of final product bags with lot number (b) (4). The final product bags from this lot did not meet the required visual inspection criteria: (b) (4) units contained embedded particulates on the product (b) (4) surface, and (b) (4) units contained embedded particulates on the …

    Contains “visual inspection*”Read the Form 483 →

  10. Dendreon Pharmaceuticals LLCInspection ended Mar 25, 2026 · FEI 3008821247 · Observation 4

    The responsibilities and procedures applicable to the quality control unit are not fully followed. A. Your firm uses a contract manufacturer to (b) (4) (b) (4) of your (b) (4). Your firm's quality control unit does not ensure that the final visual inspection for the (b) (4) solution is completed and acceptable for release. For example, your quality control unit did not document the reason for rejection provided by the contract manufacturer for …

    Contains “visual inspection*”Read the Form 483 →

  11. Dendreon Pharmaceuticals LLCInspection ended Mar 25, 2026 · FEI 3008821247 · Observation 8

    Employees engaged in the manufacture, processing and packing of a drug product lack the experience required to perform their assigned functions. Your firm's quality unit approved written procedure, SOP-10046.20, entitled "General Visual Inspection," effective June 13, 2025, outlines the training and qualification requirements for personnel performing visual inspections. The quality unit failed to provide documents and demonstrate visual …

    Contains “visual inspection*”Read the Form 483 →

  12. Bausch and Lomb IncorporatedInspection ended Mar 20, 2026 · FEI 1000113778 · Observation 1

    … However, your firm failed to characterize the black foreign matter that was in the cap and/or of the container. The following complaints were observed in relation to the complaints related to black foreign substances, include but are not limited to: (b) (@) "small black ball of matter dispense from the bottle" 1377182 Foreign Matter 1361398 "black oily substance on the tubes and the tubes appear to have a fuzzy substance on the tubes" …

    Contains “foreign matter”Read the Form 483 →

  13. SCA Pharmaceuticals LLCInspection ended Mar 13, 2026 · FEI 3013736415 · Observation 2

    … These deviation investigations have been described as Investigation Major Particulate Matter DRL Threshold Exceedance, 100% Visual Inspection Particulate Matter Threshold Exceedance, AQL Failure, and Major DRL Particulate Matter Threshold Exceedance. Since December 2024, your firm has initiated approximately 110 deviation investigations due to visual inspection failures for particulates. The majority were initiated due to contaminates observed …

    Contains “particulate matter”Read the Form 483 →

  14. Hospira, Inc.Inspection ended Mar 10, 2026 · FEI 1925262 · Observation 5

    … Your firm lacks adequate quality oversight to ensure Acceptable Quality Level (AQL) samples are taken at intervals that are representative of the entire batch. SOP-96072, Auditing of Production Operations, Section E.3 states, "To obtain representative samples for any configuration type, samples must be taken from a minimum of lz across the batch." i. During review of Visual Inspection (VI) AQL batch results for Batch #4 dated 16 February 2026, a …

    Contains “AQL”Read the Form 483 →

  15. Unilab Chemicals and Pharmaceuticals Private Ltd.Inspection ended Feb 27, 2026 · FEI 3004985767 · Observation 5

    There is a failure to clean equipment and utensils to prevent contamination or carry-over of a material that would alter the quality of the API beyond the official or other established specifications. Specifically, There are no standard operating procedures or established instructions to perform and document a visual inspection of equipment subsequent to cleaning operations. For example: During my walkthrough of the Bulk Drug (API) Manufacturing …

    Contains “visual inspection*”Read the Form 483 →

  16. Eugia Pharma Specialities LimitedInspection ended Feb 27, 2026 · FEI 3011960448 · Observation 3

    OBSERVATION 3 Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Employees engaged in visual inspection of sterile finished pharmaceutical products work under (b)(14); however, the qualification of visual inspection the first time the employee is qualified is not …

    Contains “visual inspection*”Read the Form 483 →

  17. Eugia Pharma Specialities LimitedInspection ended Feb 27, 2026 · FEI 3011960448 · Observation 4

    … adding new preventative maintenance to the (b)(4), adding a review of (b)(4) inspection challenge vial for larger glass pieces, and requalification of the visual inspection employees; however, there is no discussion of whether the glass vials used for the product are still acceptable or why the visual inspection was unable to see the glass in the time and conditions of the visual inspection operations, which were changed. 2. Investigation …

    Contains “visual inspection*”Read the Form 483 →

  18. RayzeBio, IncInspection ended Feb 24, 2026 · FEI 3030530655 · Observation 2

    … Per SOP-00110 ("(b)(4) Testing," v1, effective 07/08/2025), (b)(4) testing comprises two phases: visual inspection and testing using the (b)(4) testing unit. Additionally, the MBR requires (b)(4) and (b)(4) testing. However, (b)(4) are not (b)(4) tested (b)(4) during routine manufacturing. F. The (b)(4) for EQ-00605-IN and EQ-00606-IN in the Suite (b)(4) manufacturing line, and EQ-00687-IN and EQ-00688-IN in the Suite (b)(4) manufacturing line, …

    Contains “visual inspection*”Read the Form 483 →

  19. RayzeBio, IncInspection ended Feb 24, 2026 · FEI 3030530655 · Observation 8

    Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training required to perform their assigned functions. Specifically, Operators performing 100% manual visual inspection of (b)(4) finished vials lack adequate training per SOP-00134 (Visual Inspection Guidelines, v3, effective 11/21/2025). While the SOP defines three defect classifications (Critical, Major, Minor) covering 17 total defect types …

    Contains “visual inspection*”Read the Form 483 →

  20. Apotek Production & Laboratorier ABInspection ended Jan 29, 2026 · FEI 3003766921 · Observation 8

    Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, qualification of the gw visual inspection machine, SY1002, and operators performing the g ew visual and ge AQL inspections have not been completed using gnL ge ampoules which are intended to be used …

    Contains “visual inspection*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about visual inspection in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.