Skip to content

AstraZeneca AB

Sweden

FEI 3003342394DUNS 631892705

Company: AstraZeneca PLC · Linked by exact D-U-N-S match (230790719) in FDA registration data

FDA has 11 inspections on file for AstraZeneca AB in Sweden (FEI 3003342394), from 2010 to 2026. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.

5 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, AstraZeneca PLC (D-U-N-S 230790719), has registered 14 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
11, 2010–2026
0 OAI · 6 VAI · 4 NAI
Inspections with 483 observations shown
1 of 11
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest Jul 23, 2026
Warning letters
None on file
Import refusals
5 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

11 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 2 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate deviation investigations for foreign particles

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, Your firm's investigations of deviations are not always adequate. a. Quality Event QE-239020 was initiated 16NOV2025 following the identification of foreign particles [illegible] tablets. Analytical characterization identified the particles as containing [illegible] [illegible] batches of [illegible] [illegible] were affected: [illegible] Strength Batch Expiration Date Quantity of tablets manufactured Quantity of Tablets Inspected Quantity of Tablets found with foreign [illegible] [illegible] Despite the inability to conclusively identify the source of the [illegible] material, your investigation was closed. No additional investigation was conducted to definitively determine the origin of the [illegible] material to prevent recurrence. b. Quality Event QE-226480 was initiated 11SEP2025 during the manufacture [illegible] mg tablets, Batch [illegible] QTY: [illegible] tablets, EXP: [illegible] when four instances of [illegible] were observed in [illegible] An abnormal [illegible] was first detected during sublot [illegible] Subsequent [illegible] with [illegible] variation and [illegible] surfaces. Tablets [illegible] sublots [illegible] showed [illegible] from these sublots were discarded [illegible] with inadequate [illegible] Affected sublots were identified through in-process observation and appearance inspection and were subsequently discarded. The root cause was determined to be equipment performance, as the [illegible] was not [illegible] The correction in the [illegible] included cleaning the [illegible] for each sublot during the batch. Despite the [illegible] four times, no corrective and preventive action (CAPA) was initiated, and the issue was deemed minor.

    2. Observation 2

      Inadequate CAPA and QC procedures for particulates

      The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, Your firm's CAPA system is not always adequate to ensure deviations have appropriate measures implemented to prevent recurrence. During the manufacturing of [illegible] mg tablets, Batch [illegible] QTY: [illegible] tablets, EXP: [illegible], manufactured from [illegible] through [illegible], in-process appearance testing revealed four tablets containing foreign particulate matter. This was from the inspection of [illegible] tablets. Quality Event QE-239020 was initiated 16NOV2025, and your investigation attributed the defect to a worn tablet press. However, the preventative maintenance program was not updated to address the equipment wear condition that caused this deviation.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. NAINo objectionable conditions that need follow-upDevices · Postmarket Assurance: DevicesNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  8. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  9. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  10. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  11. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 23, 2026. Each one asked for a Form 483.

  • Inspection ending Apr 10, 2026Not classified yet

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jun 4, 2026FDA-FOIA-2026-5548Form 483· 1 of 2 sitesRecords released
  • Inspection date not given

    1 request. FDA released records in answer to a request for its Form 483 on Aug 19, 2026. FDAgent holds no copy that FDA posted.

    1. Jul 23, 2026FDA-FOIA-2026-7106Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3003342394, one row per refused product line.

5 refusals from 2017-01-04 to 2025-11-17 · charged UNAPPROVED on 4, NOT LISTED on 1 · no FDA sample analysis

FDA firm profile
  • 2025-11-17

    CANDESARTAN CILEXETIL (ANTI-HYPERTENSIVE - PART II)62OCA19

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-7648528-6/20002/1

  • 2025-05-28

    ESOMEPRAZOLE MAGNESIUM (ANTI-SECRETORY)62TDA06

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-8401476-8/141/1

  • 2023-12-15

    CARDIAC DEPRESSANT N.E.C.63ECA99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Southeast Imports799-8316376-7/21/1

  • 2022-09-02

    MISCELLANEOUS PATENT MEDICINES, ETC.66VCB99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-0609323-2/11/1

  • 2017-01-04

    ROSUVASTATIN CALCIUM61JAA16

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-8337710-7/11/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
AstraZeneca PLCD-U-N-S 230790719

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names AstraZeneca PLC (D-U-N-S 230790719) as the registrant for this site and 14 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3003342394 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3003342394. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.