AstraZeneca Pharmaceuticals, LP
508 Wrangler Dr, Coppell, Texas, United States
FEI 3010199915DUNS 081032900
Company: AstraZeneca PLC · Linked by exact D-U-N-S match (230790719) in FDA registration data
FDA has 5 inspections on file for AstraZeneca Pharmaceuticals, LP in Coppell, Texas (FEI 3010199915), from 2015 to 2026. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
The most recent OAI inspection ended on Jan 30, 2017. No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2027. Its registrant, AstraZeneca PLC (D-U-N-S 230790719), has registered 14 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 5, 2015–2026
- 2 OAI · 0 VAI · 3 NAI
- Inspections with 483 observations shown
- 1 of 5
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Process validation lacks prospective control
OBSERVATION 1 Process validation procedures do not ensure the integrity of process validation, and the quality unit does not retain the authority to accept or reject batches conducted in accordance with process validation. Specifically, your firm's manufacturing process validation of (b) (4) (b) (4) does not predefine batches of drug product subject to the validation. Protocol (b) (4) and (b) (4) specify (b) (4) "At least , acceptable challenges shall be achieved." Per your firm's Validation Director, this requirement means that your firm must successfully manufacture (b) (4) batches of API. Both these validation protocols state "Each protocol deviation requires a written investigation with the impact to the validation documented." There is no documentation specifying that batches of (b) (4) (b) (4) were chosen prospectively. The validation protocols and batch records are silent with regards to which batches are intended to support process validation. Furthermore, there is no consideration of process validation in light of batch campaigns. Specifically (b) (4) per document TD16-042-RPT major cleans occur between batches and it is not addressed how your (b) (4) (b) (4) process validation accounts for this event. Additionally, validation for Reactors and began immediately after an end of campaign ((b) (4)) cleaning, thus there is no assessment of how a batch validation (b) (4) is representative of a batch campaign. Additionally, the following anomalies/ deviations from the validation protocol were noted: (b) (4) (b) (4) a) During validation of Reactor an initial validation batch was manufactured ( ). Subsequently, a non-validation, development batch was manufactured (b) (4) ) on this reactor. Per your firm's Validation Director, this batch is solely for development and not intended to be considered a process validation batch (this batch is intended to address difficulties meeting specification for ). There is no formal documentation that the Quality Unit authorized this nonconformity with the validation protocol, and no protocol deviation was initiated. The manufacturing parameters for batch (b) (4) varied from the validation parameters of batch (b) (4). b) During validation of Reactor batch (b) (4) the validation batch of this reactor was aborted by manufacturing due to an equipment malfunction with no concurrence by the Quality Unit. Manufacturing " " this material on November 04, 2016, and a nonconformance was not opened until November 07, 2016. There is no formal documentation that the Quality Unit authorized this manufacturing event to be aborted, and no protocol deviation was initiated. c) During validation of Reactor batch (b) (4) the validation batch of this reactor was aborted. Your firm then manufactured an additional validation batch ((b) (4) ) and subsequently began the manufacture of "(b) (4) ". The requirement of "At least (b) (4) , acceptable challenges shall be achieved" per validation protocol was not met. There is no documentation supporting completion of process validation given this lack of adherence to the respective validation protocol ((b) (4)). The Quality Unit has not approved this decision. d) validation batches were manufactured on Reactor as a part of process validation. Subsequently, batches deemed "(b) (4) Batch" were manufactured. However, your firm's Quality Unit has failed to complete review of any of the validation batches per document FORM-QA-018. For all aforementioned events, there is no documentation of authorization by the Quality Unit to deviate from the respective validation protocols.
- Observation 2
Equipment contamination and residues observed
OBSERVATION 2 Buildings, facilities and equipment are not maintained to ensure the API's identity, strength, quality and purity. (b) (4) Reactor On 01/19/2016 we observed the interior face of the (b) (4) gasket was worn-out with loose threads visible. Black particulates were visible on the interior face of the gasket. Additionally, black, white and red colored residues were visible in the interior of the reactor. See below for nonconformance reports related to particulates/ residues. (b) (4) Reactor We observed tearing of the head gasket in the interior of the reactor (product contact surface), such that extended portions of the gasket were missing in several locations. Throughout the inspection we were unable to ascertain the (b) (4) of the gasket and potential product impact. The interior face of the (b) (4) gasket exhibited warping and wear (loose threads separating from this gasket towards the interior of the reactor was observed). This same reactor was the subject of nonconformance NCC16-022 (opened 10/13/2016), which was opened for a "tear in the head gasket". This nonconformance then goes onto identify that "gasket material was missing that could have potentially transferred into the (b) (4) while processing lot (b) (4)." Subsequently this gasket was replaced. Nonetheless, a similar condition was observed in January of 2017, after installation of a new gasket. (b) (4) On 01/19/2016 we observed the mesh to contain gray and black residue / material. It was noted that the drug product subject to (b) (4) is white. Your firm has initiated investigations related to gray and black residues/ materials as follows: a) Nonconformance NCC16-017 (10/05/2016) (supported with Research Report TD16-150 (January of 2017)) was opened in response to "discolored material (residue) was discovered during the (b) (4) of the (b) (4)." The probable cause was determined to be a (b) (4) like material with a "slightly" different elemental composition. (b) (4) b) Nonconformance NCC16-033 (12/07/2016) was initiated due to address particulates in (b) (4) (b) (4) samples of various lots of . This report goes on to explain "There is no good guidance from the FDA on what can be considered an acceptable level of insoluble particulate matter within product" under the product impact assessment. This nonconformance is an interim report. c) Nonconformance NCCIS-035 (12/21/2015) was opened due to "grey particles" in a sample for lot (b) (4) (supported with Research Report TD16-008). This report concludes that the particulates are "composed of the (b) (4) and their (b) (4) composition very likely caused their gray appearance to the naked eye." We identified additional reports from your auxiliary laboratory related to unknown or foreign material relating to the manufacturing process.
Show observations 3 to 6
- Observation 3
Specification not justified on scale-up
OBSERVATION 3 (b) (4) The specification of (b) (4) ( - (b) (4) designated (b) (4) is (b) (4) not justified with regard to the manufacturing process of . The manufacturing process for (b) (4) has progressed from (b) (4) , and (b) (4) (b) (4) finally . The for the various manufacturing scales is presented in the table below: (b) (4) Actual ·Values Observed (b) (4) Given the table above, your firm had failed to conduct an investigation to isolate the factor contributing (b) (4) to the elevated values upon scale-up of the manufacturing process. Moreover, your firm opened (b) (4) nonconformance NCC 17-002 in January of 2017 to identify the root cause of the trending towards failing specification. Since October of 2016, 5 out-of-specification reports have been generated for (b) (4) (b) (4). On 01/25/2017, to address the values near specification, your firm's Head of Quality specified that upon (b) (4) your firm intends to (b) (4) to adjust the (b) (4) specification. Furthermore, firm management expressed that failures in were expected to result in failing batches based on the current specification and could be dealt with through rejecting batches. Therefore, it is unclear how the firm is addressing the manufacturing process with regards to specifications of (b) (4).
- Observation 4
Inadequate electronic data controls
OBSERVATION 4 Proper controls are not exercised over computerized systems used for analytical testing to ensure drug products meet their specified quality attributes. I. Proper controls have not been implemented to ensure the integrity of electronic data in various analytical laboratory instrumentation: (b) (4) (b) (4) a) In testing of an analytical standard termed ", your firm conducted duplicate testing due to anomalous results obtained during initial testing. The initial run was conducted (b) (4) (b) (4) and termed "(b) (4) " and the duplicate testing was conducted (b) (4) and (b) (4) termed " ". No investigation was opened in response to the initial test results. b) On 07/20/2016, file "(b) (4) " was deleted. No investigation into the file deletion had been conducted. Your firm's Quality Assurance Engineer could not explain this event. (b) (4) a) Your firm's (b) (4) Instrument operating with software (b) (4) lacks audit trails. Your firm failed to conduct any sort of analysis into the implications of this instrument lacking appropriate controls. This equipment is used to assess the compliance of all batches to specification. b) Samples (b) (4) and (b) (4) were re-run due to "instrument issues". No investigation was conducted. (b) (4) (b) (4) System: (b) (4) a) Power outages and instrument errors hindered testing of (b) (4) Moreover, such a situation rendered data for (b) (4) - (b) (4) deleted and not retrievable. There are no investigations into these events. (b) (4) (b) (4) b) (b) (4) and (b) (4) were re-tested due to a "failed verification." The verification failed; subsequently the samples were tested and then re-tested. This practice is inconsistent with SOP SOP-QC-060, which specifies "Prior to analyzing samples analyze the (b) (4) ". No investigation was conducted. c) During the analysis of (b) (4) on July of 2016, a communication failure resulting from a breaker being inadvertently switched off hindered analysis. No investigation was conducted. (b) (4) System: (d) The (b) (4) operates with software that has no user restrictions and enables deletion of data. (b) (4) (b) (4) : (b) (4) (b) (4) (b) (4) a) and experienced an " error." (b) (4) . No investigation was conducted. (b) (4) : b) The (b) (4) Instrument operating with (b) (4) Version (b) (4) that has no user restrictions and enables deletion of data. II. Moreover, analytical samples and testing lack traceability: Individuals designated as R&D personnel utilize the aforementioned equipment and conducts analytical testing. As such, the purpose and content of analytical testing conducted in the QC department is not readily identifiable. Additionally, there is a lack of complete traceability or accountability for manufacturing samples submitted for analysis by your auxiliary laboratory. There is not sample reconciliation for samples indicated in "Sample log-in" and the respective "Request For Analysis" forms.
- Observation 5
Insufficient cleaning validation for equipment
OBSERVATION 5 Cleaning validation of the equipment used to manufacture APT is not established to ensure that contamination that would alter the safety, identity, strength, quality or purity of the drug product is prevented. Specifically, (b) (4) Between March 2016 and January 2016 your firm has manufactured batches of (b) (4) (b) (4) The studies performed to support the validation of the cleaning of processing equipment used in the manufacturing process of (b) (4) : (b) (4) a) There is no prospective justification for equipment cleaning, the maximum campaign length ( batches), and equipment hold times. (b) (4) • Document CV-15-001-RPT "Verification of Cleaning Processes for Manufacture of (b) (4)" was limited to a retrospective review of batch release testing data for batches manufactured between November 2015 and April 2016. This study was presented as evidence to support equipment cleaning, the "maximum number of batches in a campaign" and hold times. Your firm's Head of Quality acknowledged that these studies relied on API passing specification to determine cleaning effectiveness. (b) (4) • Document TD16-042-RPT "Evaluation of API for Bracketing of Cleaning Campaigns", Revision 00 is an update to Document CV-15-001-RPT. This study further assesses process development batches via (b) (4) testing with additional sampling and microbiological testing utilized to support an extended campaign length. No assessment of manufacturing equipment was conducted. b) The processes and acceptance criteria used to justify the adequacy of the removal of the white residues observed on the inner surfaces of your reactors used in the manufacturing process was not defined prior to execution (TD-16-034). This study consisted solely of an undefined collection of samples and then analyzing this material with (b) (4) and (b) (4) (b) (4). The sampling strategy and rationale for samples analyzed were not discernable from this report.
- Observation 6
Analytical method reliability not demonstrated
OBSERVATION 6 The reliability of test method TM-026 to quantitate elemental composition of (b) (4) (b) (4) has not been demonstrated. Your firm's specifications for (b) (4) (SPEC-DS-001) define a limit of (b) (4) (b) (4) (b) (4) content to - . Upon review of (b) (4) testing for multiple batches of (b) (4) we noted sample preparations had been re-tested. The re-testing of samples exhibited the variation summarized by the following chart: (b) (4) Batch Initial Test Results Second Test Results (b) (4) (b) (4) (b) (4) / '
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- AstraZeneca PLCD-U-N-S 230790719
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names AstraZeneca PLC (D-U-N-S 230790719) as the registrant for this site and 14 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- AstraZeneca Pharmaceuticals LPNewark, Delaware · FEI 25171007 inspections7latestJun 26, 2026VAINone on file
- AstraZeneca ABSweden · FEI 300334239411 inspections11latestApr 10, 2026None on file
- AstraZeneca ABSodertalje, Sweden · FEI 30028064119 inspections9latestMar 19, 2026VAINone on file
- AstraZeneca Pharmaceuticals LPPhiladelphia, Pennsylvania · FEI 30048297149 inspections9latestJun 24, 2025NAINone on file
- IPR Pharmaceuticals, IncCanovanas, Puerto Rico · FEI 30030094227 inspections7latestMay 12, 2025NAINone on file
- MedImmune UK LimitedLiverpool, United Kingdom · FEI 30040661129 inspections9latestMay 16, 2024VAINone on file
- AstraZeneca Nijmegen B.V.Nijmegen, Netherlands · FEI 30030004726 inspections6latestApr 10, 2024VAINone on file
- AstraZeneca Pharmaceuticals LPMount Vernon, Indiana · FEI 18256628 inspections8latestSep 19, 2023VAINone on file
- AstraZeneca UK LtdMacclesfield, United Kingdom · FEI 30028503176 inspections6latestApr 27, 2023VAINone on file
- AstraZeneca Pharmaceuticals LPFrederick, Maryland · FEI 30026177715 inspections5latestJan 19, 2023VAINone on file
- AstraZeneca Dunkerque ProductionDordogne, France · FEI 30030638195 inspections5latestFeb 3, 2022VAINone on file
- AstraZeneca Pharmaceuticals LPRedwood City, California · FEI 30113894282 inspections2latestOct 25, 2021NAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3010199915 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3010199915. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.