Visual inspection and particulates in FDA Form 483 observations
Inspecting filled product for defects and visible particles, and investigating the particles and foreign matter found. FDAgent finds 143 such observations in 91 Form 483s issued to 88 facilities, for inspections that ended between June 2012 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 143
- Each quoted below
- Form 483s
- 91
- Posted by FDA
- Facilities
- 88
- Distinct FEIs
- Most recent
- Sep 10, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 46 in 2026
| Year | Observations |
|---|---|
| 2012 | 1 |
| 2013 | 2 |
| 2014 | 0 |
| 2015 | 0 |
| 2016 | 8 |
| 2017 | 11 |
| 2018 | 6 |
| 2019 | 10 |
| 2020 | 1 |
| 2021 | 6 |
| 2022 | 9 |
| 2023 | 17 |
| 2024 | 8 |
| 2025 | 18 |
| 2026 | 46 |
How FDAgent sorts observations into this theme
One fixed rule, applied by code to every observation FDAgent can quote. No model and no similarity score decides.
Its text contains one of these phrases
“visual inspection*” · “visually inspect*” · “visible particle*” · “visible particulate*” · “particulate matter” · “foreign matter” · “foreign particle*” · “foreign material*” · “AQL”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 143 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Suven Life Sciences Ltd.Inspection ended Feb 15, 2018 · FEI 1000623515 · Observation 2
… Your firm failed to adequately clean and visually inspect the following (b) (4) A. (b) (4)-3109 is used in the production of (b) (4) API/Intermediate: I observed what appears to be discoloration resembling (b) (4) inside the (b) (4) 3109 in areas that come into direct contact with drug product. The status of this non-dedicated (b) (4) was identified as cleaned. B. (b) (4)-3139: I observed the gasket used to protect the (b) (4) and the (b) (4) of …
Contains “visually inspect*”Read the Form 483 →
Shilpa Medicare LimitedInspection ended Nov 30, 2017 · FEI 3009876430 · Observation 10
The following defects are not reflected in the visual inspection Kits used to train the visual inspectors; vial/liquid, vials: Sealing (non-integral), broken/cracks, changes in liquid color, absence of stopper/seal, less volume, more volume, color particle, coding, empty vial, molding defects, scratches, spot on [illegible], spot on seal. vial/liquid, vials: Broken/cracks, less volume, more volume, empty, appearance, sealing (non-integral). vial …
Contains “visual inspection*”Read the Form 483 →
Aurobindo Pharma Ltd. Unit VIInspection ended Sep 1, 2017 · FEI 3004021263 · Observation 1
… 100% Visual inspection for defects of the®® and adequate operator verification. Additionally, your firm's investigation into the cause of these complaints identified ®® of the the®@ [illegible] on the®® equipment as the most likely cause of the damaged®® Beginning on 5/7/15 this same piece of equipment continued to be used in the ®® of the®® desiccant [illegible] as stated in item 2 above followed by a 100% visual inspection. On 12/28/15 a …
Contains “visual inspection*”Read the Form 483 →
Meridian Medical Technologies, Inc. a Pfizer CompanyInspection ended Mar 24, 2017 · FEI 1950222 · Observation 2
… These repeated 100% visual inspections however, do not remove all of the defective units. 1. Based upon review of production data, (b) (4)% of the batches from the ATNAA / DuoDote process ((b) (4) out of (b) (4) batches inspected between 1 JAN 2015 and 21 FEB 2017) are not complying with the specified criteria for percent defect for critical, major, or minor defects during the 100% manual inspection. Your firm performed an additional 100% …
Contains “visual inspection*”Read the Form 483 →
Meridian Medical Technologies, Inc. a Pfizer CompanyInspection ended Mar 24, 2017 · FEI 1950222 · Observation 4
… The AQL (Acceptable Quality Limits) sampling plan and associated (b) (4) is not commensurate with the product risk based on intended use and design inputs of the product. B. Your firm does not currently distinguish the failure modes of rejected components/units that are collected in reject bins on the EpiPen manufacturing assembly line. In addition, your firm does not currently track or trend the rejects from the EpiPen assembly manufacturing …
Contains “AQL”Read the Form 483 →
Meridian Medical Technologies, Inc. a Pfizer CompanyInspection ended Mar 24, 2017 · FEI 1950222 · Observation 6
… Your inputs/requirements list an AQL (b) (4) for critical tests, which equates to establishing a certain confidence of no more than (b) (4) failures per (b) (4) products. (b) (4) failures of delivered dose, or other critical tests, per (b) (4) EpiPen, EpiPen Jr., or (b) (4) products does not give assurance of the level of reliability commensurate with the risk of failure of a critical test as defined by your firm (e.g. delivered dose, (b) (4), …
Contains “AQL”Read the Form 483 →
Meridian Medical Technologies, Inc. a Pfizer CompanyInspection ended Mar 24, 2017 · FEI 1950222 · Observation 14
Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training required to perform their assigned functions. Specifically, your firm did not conduct training for employees involved in the visual inspection for (b) (4) used in EpiPen manufacturing. For example, your Site Lead reported there is no formal OJT for the visual (b) (4) evaluation (inspection) before the (b) (4) is introduced into the process. …
Contains “visual inspection*”Read the Form 483 →
Alkem Laboratories LimitedInspection ended Mar 10, 2017 · FEI 3006370533 · Observation 3
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, the 100% visual inspection of filled capsules conducted in Block (b) (4) prior to packaging, is performed manually on a (b) (4) There is no written procedure describing this process, training specific to this manual operation, …
Contains “visual inspection*”Read the Form 483 →
Bayer AG PharmaInspection ended Jan 20, 2017 · FEI 3002806462 · Observation 2
Procedures to ensure reliable detection of particulate matter in parenteral products have not been established. 1. During routine visual inspection, filled (b) (4) are visually inspected immediately after exiting the filling area. The filling process introduces (b) (4) bubbles that create cloudiness in the solution that takes a (b) (4) to subside. This cloudiness was observed to be present at the time of the visual inspection and could obscure …
Contains “particulate matter”Read the Form 483 →
Bayer AG PharmaInspection ended Jan 20, 2017 · FEI 3002806462 · Observation 3
Procedures for cleaning of the equipment and facility are not established and followed. 1. The (b) (4) building has (b) (4) (b) (4). They are not product dedicated, including (b) (4) (b) (4) that are shared use between (b) (4) products and non-(b) (4) products. Cleaning validation of the equipment failed to evaluate hard to clean and hard to visually inspect places, such as the (b) (4). Inspection of the (b) (4) (b) (4) revealed: a. The "clean" …
Contains “visually inspect*”Read the Form 483 →
Bayer AG PharmaInspection ended Jan 20, 2017 · FEI 3002806462 · Observation 4
… Numerous set-up parameter forms for setting tablet visual inspection parameters were observed in the waste bin. The original documents should have been maintained as part of the raw data for setting of parameters. Additionally, some of the discarded forms had been written using pencil. e. Numerous original signed training records were found in the waste bin. The original records are required to be maintained per SOP 3-040-127. 2. In the …
Contains “visual inspection*”Read the Form 483 →
Bayer AG PharmaInspection ended Jan 20, 2017 · FEI 3002806462 · Observation 5
… Retain samples were not evaluated when foreign matter was reported in the following complaints: 2015-009605 dark particles in solution for batch (b) (4) of (b) (4), 2016-020559 fiber in solution for batch (b) (4) of (b) (4), 2016-007422 small fibers in batch (b) (4) of (b) (4). 3. The complaint handling procedure 3-020-082 does not describe when analytical testing of returned complaints samples will be conducted. Complaint 2015-024059 documented …
Contains “foreign matter”Read the Form 483 →
Zhejiang Huahai Pharmaceutical Co. Ltd.Inspection ended Nov 18, 2016 · FEI 3003999190 · Observation 1
… No defect set of vials is maintained for training and qualification of the visual inspection process
Contains “visual inspection*”Read the Form 483 →
Zhejiang Huahai Pharmaceutical Co. Ltd.Inspection ended Nov 18, 2016 · FEI 3003999190 · Observation 2
… Limits on reject types are not established in the visual inspection procedures.
Contains “visual inspection*”Read the Form 483 →
Indoco Remedies LimitedInspection ended Sep 4, 2016 · FEI 3005124189 · Observation 4
… The defect library used for qualification of personnel that will be performing visual inspection of sterile injectable products does not specifically include units containing small particles, which may be difficult to detect. It contains defects for glass particles, ®® | particles, and ®® particles. Pending application products| ©@® ®®@ ®6 Injection, and] Cw ©O®@ ®® piection, will be inspected by personnel that have been insufficiently qualified …
Contains “visual inspection*”Read the Form 483 →
Claris Injectables LimitedInspection ended Aug 26, 2016 · FEI 3004610460 · Observation 4
… However, you have not validated the number of cleaning and sterilization cycles through which the goggles can be processed and are relying on visual inspection of the goggles by clean room operators. c) Your Disinfectant Validation Reports dated August 2011 and November 2013 identify disinfectant/sporicidal contact times as for and | @ for’ Ee However, no contact time is specified in SOP PRD/006 on Maintenance of Clean Room, which is applicable …
Contains “visual inspection*”Read the Form 483 →
Claris Injectables LimitedInspection ended Aug 26, 2016 · FEI 3004610460 · Observation 5
QUALITY SYSTEM OBSERVATION 5 Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training required to perform their assigned functions. Specifically, a) SOP PRD/041 Automatic Visual Inspection Procedure, operators performing manual visual examinations of filled drug products are trained to identify defects utilizing test kits. The inspector observed selected examples of filled bags utilized for …
Contains “visual inspection*”Read the Form 483 →
Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 5
… The visual inspection was reviewed and released by the Pharmacist in Charge. This lot [illegible]. c) Your firm generated a Quality Related Event Report Form (no SOP in place regarding this form) for a sterility failure for Testosterone Cypionate 210 mg/mL multidose [illegible]. No investigation was conducted by the firm or the control [testing] lab (CTL). Re-training of the pharmacist. This batch was rejected according [illegible] to the batch …
Contains “visual inspection*”Read the Form 483 →
Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 6
6. Your firm failed to follow SOP No. 9.014 Procedures in [Chemicals]. As a result, your firm failed to conduct an [illegible] following: a) During the visual inspection of Testosterone Enanthate 210 mg/mL, pharmacist G.O.H observed two vials containing particulate. [illegible] distribution and it is unclear if the two vials containing [illegible] In addition, the batch record does not state that a (b)(4) sterilization. b) During the current FDA …
Contains “visual inspection*”Read the Form 483 →
Cosma SpAInspection ended Jan 15, 2016 · FEI 3002806754 · Observation 6
… The [illegible] was released based on a review of the cleaning batch record and visual inspection as the reviewer was unaware swab and rinse samples were taken and needed to be acceptable prior to the release of the equipment. 3. Operators do not document the amount of solvents or water used during the execution of cleaning records. 4. Justification that the length of the production campaign performed prior to cleaning did not result in the …
Contains “visual inspection*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.192Production record review16
- 21 CFR 211.100Written procedures; deviations12
- 21 CFR 211.113Control of microbiological contamination9
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.25Personnel qualifications6
- 21 CFR 211.160General requirements6
- 21 CFR 211.110Sampling and testing of in-process materials and drug products3
- 21 CFR 211.165Testing and release for distribution3
- 21 CFR 211.63Equipment design, size, and location2
- 21 CFR 211.67Equipment cleaning and maintenance2
Ask FDAgent about visual inspection in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.