Quality unit responsibilities in FDA Form 483 observations
The quality control unit's authority and duties: approving or rejecting materials and batches, reviewing records and procedures, and overseeing investigations. FDAgent finds 141 such observations in 103 Form 483s issued to 100 facilities, for inspections that ended between March 2012 and August 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 141
- Each quoted below
- Form 483s
- 103
- Posted by FDA
- Facilities
- 100
- Distinct FEIs
- Most recent
- Aug 12, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 50 in 2026
| Year | Observations |
|---|---|
| 2012 | 1 |
| 2013 | 0 |
| 2014 | 0 |
| 2015 | 1 |
| 2016 | 5 |
| 2017 | 5 |
| 2018 | 4 |
| 2019 | 2 |
| 2020 | 0 |
| 2021 | 3 |
| 2022 | 9 |
| 2023 | 17 |
| 2024 | 12 |
| 2025 | 32 |
| 2026 | 50 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“quality unit*” · “quality control unit*” · “QCU” · “QU” · “quality assurance unit*” · “quality assurance department*” · “QA unit*”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 141 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Galaxy Medical Products LLCInspection ended Apr 28, 2026 · FEI 3010888324 · Observation 1
The quality control unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred. Specifically, Your firm failed to document and investigate the use of an out-of-calibration thermometer during the filling of (b) (4) cylinders. On 04/27/2026, an out-of-calibration thermometer (Serial # (b) (4)) that had exceeded its calibration due date by approximately four months was …
Opens with FDA's citation wording for 21 CFR 211.22(a)Read the Form 483 →
Jiangsu Hansoh Pharmaceutical Group Co Ltd.Inspection ended Apr 24, 2026 · FEI 3008316144 · Observation 3
… Your visual inspection qualification program lacks adequate Quality Unit over-site and control. Production personnel maintain qualification kits, administer qualification tests, make pass/fail determination with only a Quality review of the bottle condition. This arrangement fails to ensure the proper administration of qualification tests according to a written procedure as well as fails to ensure objective evaluation of inspector performance. 2. …
Contains “quality unit*”Read the Form 483 →
Cliantha Research LimitedInspection ended Apr 17, 2026 · FEI 3017682080 · Observation 5
5. Your Quality unit failed to perform thorough and/or adequate laboratory investigations (identified by firm as event or incident) as required by the control procedure 100AB014, Version 4, Laboratory Event Management, Effective date: 23Jun2025; to ensure the appropriate root cause, propose adequate corrective / preventive actions, scientific justification to invalidate original result and management of events for any bioanalytical phase of …
Contains “quality unit*”Read the Form 483 →
Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 7
The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality and purity of drug products. Your firm failed to ensure adequate oversight during the installation of a (b)(4) valve within a Grade A aseptic processing environment RABS equipment #(b)(4) on April 8, 2026. Quality Assurance personnel were observed to be positioned away from the operation with obstructed …
Opens with FDA's citation wording for 21 CFR 211.22(c)Read the Form 483 →
AstraZeneca ABInspection ended Apr 10, 2026 · FEI 3003342394 · Observation 2
The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, Your firm's CAPA system is not always adequate to ensure deviations have appropriate measures implemented to prevent recurrence. During the manufacturing of [illegible] mg tablets, Batch [illegible] QTY: [illegible] tablets, EXP: [illegible], manufactured from [illegible] through [illegible], in-process appearance testing revealed four …
Opens with FDA's citation wording for 21 CFR 211.22(d)Read the Form 483 →
Conroe Welding Supply, IncInspection ended Apr 3, 2026 · FEI 1625647 · Observation 1
There is no quality unit. Specifically, Your firm has not established, documented, or implemented an effective quality management system and current good manufacturing practice (cGMP) that involves the active participation of management, quality, and appropriate manufacturing personnel. Your firm's quality unit lacks sufficient resources to carry out its responsibilities and consistently ensure medical gas quality. For example: A. Your firm has …
Contains “quality unit*”Read the Form 483 →
Conroe Welding Supply, IncInspection ended Apr 3, 2026 · FEI 1625647 · Observation 3
The quality unit failed to review and approve manufacturing production and control records, including those for packaging and labeling, to determine compliance with all established, approved written procedures before batches were released or distributed. Specifically, The product release approver signature line was blank on batch records dated (b) (4) (lots (b) (4)), and the batches were released without any documented approval. These lots were …
Contains “quality unit*”Read the Form 483 →
Fujifilm Diosynth Biotechnologies USA Inc.Inspection ended Mar 27, 2026 · FEI 3000718852 · Observation 2
… Your quality unit failed to evaluate whether this system continues to operate in a validated state following these modifications. Furthermore, you have not conducted a risk assessment to support that your bioburden sampling for (b) (4) (b) (4) post these corrective actions is adequate to verify complete biofilm removal. Per your Associate Director of Facilities, this (b) (4) is used as starting material for the (b) (4) system, cleaning of …
Contains “quality unit*”Read the Form 483 →
Dendreon Pharmaceuticals LLCInspection ended Mar 25, 2026 · FEI 3008821247 · Observation 1
Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up. Although your firm's Quality Unit approved a written procedure, SOP-11058.33, entitled "Nonconformance Reporting," effective August 9, 2025, which defines the nonconformance management process, investigation, assessment of impact, determination of root …
Contains “quality unit*”Read the Form 483 →
Dendreon Pharmaceuticals LLCInspection ended Mar 25, 2026 · FEI 3008821247 · Observation 4
The responsibilities and procedures applicable to the quality control unit are not fully followed. A. Your firm uses a contract manufacturer to (b) (4) (b) (4) of your (b) (4). Your firm's quality control unit does not ensure that the final visual inspection for the (b) (4) solution is completed and acceptable for release. For example, your quality control unit did not document the reason for rejection provided by the contract manufacturer for …
Opens with FDA's citation wording for 21 CFR 211.22(d)Read the Form 483 →
Dendreon Pharmaceuticals LLCInspection ended Mar 25, 2026 · FEI 3008821247 · Observation 8
Employees engaged in the manufacture, processing and packing of a drug product lack the experience required to perform their assigned functions. Your firm's quality unit approved written procedure, SOP-10046.20, entitled "General Visual Inspection," effective June 13, 2025, outlines the training and qualification requirements for personnel performing visual inspections. The quality unit failed to provide documents and demonstrate visual …
Contains “quality unit*”Read the Form 483 →
Dendreon Pharmaceuticals LLCInspection ended Mar 25, 2026 · FEI 3008821247 · Observation 9
Reprocessing was performed without the review and approval of the quality control unit. Specifically, employees engaging in the manufacturing operation of your (b) (4) determines whether a (b) (4) should be reprocessed during packaging operations. Reprocessing can occur because of (b) (4), (b) (4), or incorrect color (b) (4). Furthermore, your firm does not have a written procedure for reprocess or rework. For example: a) (b) (4) Lot # (b) (4) …
Contains “quality control unit*”Read the Form 483 →
Spectrum Laboratory Products Inc.Inspection ended Mar 20, 2026 · FEI 2020632 · Observation 1
Your quality unit failed to record, review, and approve all appropriate quality-related documents at the time activities are performed. Specifically, During my inspection, I reviewed your Laboratory Cleaning Records (QAF877) for all available months in 2025 and 2026. These records are used to document laboratory cleaning activities as required by your SOP QC-W-8.22, Section 5.9, which states: "(b)(4) cleaning activities shall be documented in …
Contains “quality unit*”Read the Form 483 →
Protein Sciences CorporationInspection ended Mar 17, 2026 · FEI 3011286996 · Observation 1
… on February 14, 2026, for use in Flublok drug substance batch (b)(4) was not documented in (b)(4) contrary to the traceability requirements in your procedure QU.(b)(4)-0000136. During inspectional inventory of (b)(4) conducted on March 10, 2026, (b)(4) unlabeled (b)(4) were observed within a (b)(4) labeled for storage of Express SF+ Working Cell Bank from Material Lot # (b)(4). Approximately (b)(4) labels were observed as peeling off their …
Contains “QU”Read the Form 483 →
Protein Sciences CorporationInspection ended Mar 17, 2026 · FEI 3011286996 · Observation 6
The Quality Unit has failed to provide adequate oversight and ensure the implementation of effective corrective and preventive actions. Specifically, Your firm's own Product Quality Reviews (PQRs) for 2024 and 2025 identified that the root cause category of "Methods" accounted for approximately 41% and 40%, respectively, of critical/major/significant deviations in each review period. Despite this recurring trend being formally documented in two …
Contains “quality unit*”Read the Form 483 →
Hospira, Inc.Inspection ended Mar 10, 2026 · FEI 1925262 · Observation 5
Observation 5: Your firm failed to establish adequate quality control unit oversight with the responsibility and authority to approve or reject production and quality documents. Specifically, a. Your firm lacks adequate quality oversight to ensure Quality Risk Management Reports and change controls are thoroughly conducted and reviewed before approval. For example. i. Quality Risk Management Report Oversight: A Quality Risk Management Report …
Contains “quality control unit*”Read the Form 483 →
Aurorium LLCInspection ended Mar 6, 2026 · FEI 1628757 · Observation 3
OBSERVATION 3 Failure of the Quality Unit to fulfill its oversight responsibilities. Specifically, a) CAPAs are not fully documented in accordance with your established procedure entitled Corrective and Preventative Actions (MIDL-SOP-124) effective January 1, 2024; they also are not closed out in a timely manner. For example: + CP25-014 (initiated 8/15/2025), CP25-010 (initiated 7/01/2025), CP25-019 (initiated 11/17/2025), CP24-12 (initiated …
Contains “quality unit*”Read the Form 483 →
Unilab Chemicals and Pharmaceuticals Private Ltd.Inspection ended Feb 27, 2026 · FEI 3004985767 · Observation 3
The responsibilities and procedures applicable to the quality control unit are not in writing or fully followed. Specifically, The following deficiencies were observed during my inspectional walkthrough of the Quality Assurance (QA) area on February 23, 2026: A. 2025 Quality Control API test results (e.g. pH and Assay test results) were observed to be documented on loose uncontrolled template paper for commercial API batches. According to the …
Opens with FDA's citation wording for 21 CFR 211.22(d)Read the Form 483 →
Hillyard GMPInspection ended Feb 27, 2026 · FEI 3009690111 · Observation 1
… There was no documentation demonstrating that suppliers approved by the Quality Unit prior to use. b. For all component suppliers reviewed demonstrating evaluation and approval prior to use. c. No completed supplier questionnaires or audit documentation were available for review. d. There was no documentation establishing defined supplier responsibilities or quality expectations.
Contains “quality unit*”Read the Form 483 →
RayzeBio, IncInspection ended Feb 24, 2026 · FEI 3030530655 · Observation 1
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, A. Your firm's procedure SOP-00013 ("Batch Review and Release Process," v. 5, effective 10/31/2025) for shipping drug products under quarantine is inadequate. The procedure allows shipment of sterile injectable drug products to end customers before the completion of analytical tests and quality review of batch …
Opens with FDA's citation wording for 21 CFR 211.22(d)Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.22Responsibilities of quality control unitIn this theme's rule46
- 21 CFR 211.192Production record review6
- 21 CFR 211.113Control of microbiological contamination5
- 21 CFR 211.165Testing and release for distribution5
- 21 CFR 211.63Equipment design, size, and location2
- 21 CFR 211.100Written procedures; deviations2
- 21 CFR 211.160General requirements2
- 21 CFR 211.180General requirements2
- 21 CFR 211.25Personnel qualifications1
- 21 CFR 211.42Design and construction features1
Ask FDAgent about quality unit in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.