Skip to content

Laboratory controls in FDA Form 483 observations

Quality control laboratories: test methods and their validation, laboratory records and equipment, reference standards and chromatography. FDAgent finds 304 such observations in 172 Form 483s issued to 163 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
304
Each quoted below
Form 483s
172
Posted by FDA
Facilities
163
Distinct FEIs
Most recent
Sep 3, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 76 in 2026

Laboratory controls observations in Form 483s by inspection year
YearObservations
20081
20090
20100
20110
20128
20130
20145
20154
201613
201721
201823
201914
20200
20216
202218
202342
202425
202548
202676

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.16021 CFR 211.16521 CFR 211.16621 CFR 211.16721 CFR 211.17021 CFR 211.17321 CFR 211.176

The same entries the laboratory controls topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“laboratory control*” · “laboratory record*” · “laboratory investigation*” · “laboratory equipment” · “laboratory instrument*” · “laboratory data” · “laboratory test*” · “laboratory result*” · “laboratory analyst*” · “laboratory procedure*” · “laboratory notebook*” · “laboratory error*” · “QC laborator*” · “quality control laborator*” · “test method*” · “analytical method*” · “analytical procedure*” · “method validation” · “HPLC*” · “chromatograph*” · “reference standard*” · “system suitability” · “method transfer”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 304 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Piramal, Piramal Pharma LimitedInspection ended Feb 17, 2025 · FEI 3008763768 · Observation 6

    … During the inspection, the matter was isolated from the (b)(4) and sent for external laboratory testing. The identification testing demonstrated that the foreign matter originated from the [illegible] use processing activities.

    Contains “laboratory test*”Read the Form 483 →

  2. Glenmark Pharmaceuticals Ltd.Inspection ended Feb 14, 2025 · FEI 3008565058 · Observation 3

    … Approximately 75 instances of extraneous peaks have been recorded during dissolution, assay, content uniformity and impurities tests by HPLC resulting from potential contaminations since 2023. Sources of contaminations have not always been identified or have root causes been adequately supported. The root causes such as 'instrument error' (23 times), 'human error' (6 times), 'other(s)' (42 times) are under investigation.

    Contains “HPLC*”Read the Form 483 →

  3. Glenmark Pharmaceuticals Ltd.Inspection ended Feb 14, 2025 · FEI 3008565058 · Observation 4

    The accuracy, sensitivity, specificity and reproducibility of analytical methods have not been adequately documented. Specifically, Commercial drug products and Active Pharmaceutical Ingredients (API) test methods, including in-house and compendial test methods were not validated or verified appropriately. More than [illegible] and APIs are routinely released by testing with analytical test methods that have not been adequately validated or …

    Contains “analytical method*”Read the Form 483 →

  4. Zhejiang Huahai Pharmaceutical Co., Ltd.Inspection ended Jan 24, 2025 · FEI 3003999190 · Observation 6

    OBSERVATION #6 Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Analytical method validation studies have not included forced degradation studies for methods used for stability testing. For example, the US market products: J.____(b)l~blet, ~[ ~(b)l4' 0 nd l(b)l,4l Tablets, …

    Opens with FDA's citation wording for 21 CFR 211.160(b)Read the Form 483 →

  5. Hankook Cosmetics Manufacturing Co., LtdInspection ended Nov 21, 2024 · FEI 3012656014 · Observation 1

    Results of stability testing are not used in determining expiration dates. Specifically, Procedure QP-20-17, "Stability Test" requires long term stability studies for establishment and confirmation expiration date applied to OTC drug products. [illegible] drug product lots had stability (b)(4) [illegible] studies initiated between 2018 and 2019, however all of these studies were cancelled approximately three months after the stability studies …

    Opens with FDA's citation wording for 21 CFR 211.166(a)Read the Form 483 →

  6. Hankook Cosmetics Manufacturing Co., LtdInspection ended Nov 21, 2024 · FEI 3012656014 · Observation 2

    Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. Specifically, Records related to chemical and microbiological testing do not include all the information related to the execution of the test. For example, (b)(4) is tested for (b)(4) and microbial limits. The laboratory records do not include complete information related to …

    Contains “laboratory record*”Read the Form 483 →

  7. Hankook Cosmetics Manufacturing Co., LtdInspection ended Nov 21, 2024 · FEI 3012656014 · Observation 3

    … and packaging and labeling, and equipment logbooks), and the laboratory (including but not limited to analytical raw data worksheets, equipment usage logs, reference standard logs used for documenting weight, and laboratory inventory logs). C. According to QP-20-18, Product Review", product reviews are required to be (b)(4). Product reviews [illegible] drug products manufactured within [illegible] were not conducted for the approximately (b)(4) …

    Contains “reference standard*”Read the Form 483 →

  8. Hankook Cosmetics Manufacturing Co., LtdInspection ended Nov 21, 2024 · FEI 3012656014 · Observation 4

    Established sampling plans are not followed and documented at the time of performance. Specifically, Sampling of the (b)(4) system is not adequately documented, established, or justified. For example: 1. According to QP-14-02, Test Management", prior to sampling the point of use, the (b)(4) (b)(4). There is no specific time requirement that the point of use must be (b)(4) [illegible] analyst prior to collecting the sample, nor is the amount of …

    Opens with FDA's citation wording for 21 CFR 211.160(a)Read the Form 483 →

  9. Laboratoires AniosInspection ended Sep 12, 2024 · FEI 3004094142 · Observation 1

    Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, A) Your firm failed to establish specifications requiring testing of raw material (b)(4) with the respective USP Monographs for …

    Opens with FDA's citation wording for 21 CFR 211.160(b)Read the Form 483 →

  10. Laboratoires AniosInspection ended Sep 12, 2024 · FEI 3004094142 · Observation 2

    There is no written testing program designed to assess the stability characteristics of drug products. Specifically, Your firm has not established a stability testing program for your drug product (b)(4) to confirm and ensure that these products maintain their efficacy and quality attributes throughout the established shelf life (b)(4). In addition, your stability program is deficient in that: Your most current stability study, study number …

    Opens with FDA's citation wording for 21 CFR 211.166(a)Read the Form 483 →

  11. Rechon Life Science ABInspection ended Sep 6, 2024 · FEI 3002806978 · Observation 5

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. A. Laboratory Investigation AV 2023-348 for (b) (4) mg/ml, (b) (4) ml vial, lots (b) (4) Exp. Dates (b) (4) and (b) (4) was initiated on 11/23/2023 due to out-of-trend (OOT) and out-of-specifications (OOS) assay results. Specifically, OOT …

    Contains “laboratory investigation*”Read the Form 483 →

  12. Huangshi Hygenic Material Medicine Co.Inspection ended Aug 30, 2024 · FEI 3005543486 · Observation 1

    An adequate number of batches of each drug product are not tested nor are records of such data maintained to determine an appropriate expiration date. Specifically, Your firm has not tested OTC drug products manufactured for the US market for stability to determine the expiration date. The products: (b) (4) (b) (4) are assigned (b) (4) expiration date from the date of manufacture. The product (b) (4) (b) (4) is assigned (b) (4) expiration date …

    Opens with FDA's citation wording for 21 CFR 211.166(b)Read the Form 483 →

  13. Huangshi Hygenic Material Medicine Co.Inspection ended Aug 30, 2024 · FEI 3005543486 · Observation 3

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release. Specifically, You did not perform testing of your finished product for identity and strength of each active ingredient prior to release including for a total of (b) (4) batches of the following products manufactured for the US market. (b) (4)

    Opens with FDA's citation wording for 21 CFR 211.165(a)Read the Form 483 →

  14. Huangshi Hygenic Material Medicine Co.Inspection ended Aug 30, 2024 · FEI 3005543486 · Observation 4

    Laboratory records are deficient in that they do not include a statement of the results of tests and how they compare to the established specifications. Specifically, Your firm did not perform growth promotion studies on each batch of media used for microbial testing of your finished drug products (b) (4)

    Contains “laboratory record*”Read the Form 483 →

  15. Huangshi Hygenic Material Medicine Co.Inspection ended Aug 30, 2024 · FEI 3005543486 · Observation 5

    The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, A) Your quality unit does not review electronic raw data including but not limited to identify testing of a finished product and APIs by HPLC and GC. B) Your quality unit does not review audit trails on test results including for HPLC (Waters Chromatography Data System Empower 3 and Lab Solutions) and GC (Chromleon and …

    Contains “HPLC*”Read the Form 483 →

  16. Huangshi Hygenic Material Medicine Co.Inspection ended Aug 30, 2024 · FEI 3005543486 · Observation 6

    Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. Specifically, Your firm did not perform microbial testing of the finished drug product (b) (4) (b) (4) manufactured for the US market.

    Opens with FDA's citation wording for 21 CFR 211.165(b)Read the Form 483 →

  17. Huangshi Hygenic Material Medicine Co.Inspection ended Aug 30, 2024 · FEI 3005543486 · Observation 8

    Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness and compliance with established standards. Specifically, The reviewer of microbiological test results does not verify the original raw data for accuracy and completeness.

    Contains “laboratory record*”Read the Form 483 →

  18. Qingdao Kangyuan Pharmaceutical Co., LTDInspection ended Aug 16, 2024 · FEI 3006512854 · Observation 1

    Laboratory controls do not include scientifically sound and appropriate specifications, sampling plans and test procedures designed to assure that raw materials conform to established standards of quality and/or purity. Specifically, Your firm failed to monitor the water system, so it consistently produces pharmaceutical grade water that, at a minimum, meets the USP monograph for (b)(4) water and appropriate microbial limits. Your firm's current …

    Contains “laboratory control*”Read the Form 483 →

  19. Qingdao Kangyuan Pharmaceutical Co., LTDInspection ended Aug 16, 2024 · FEI 3006512854 · Observation 3

    Failure to validate and verify the suitability of analytical methods. Specifically, (b)(4) Your firm is using the Chinese Pharmacopeia for identity testing of a raw material used in the production of (b)(4). [illegible] Chinese Pharmacopeia identity test method for (b)(4) is equivalent to, or better than, the U.S. Pharmacopeia (USP) identity test method for the same substance.

    Contains “analytical method*”Read the Form 483 →

  20. Global Calcium Private LimitedInspection ended Aug 2, 2024 · FEI 3004094136 · Observation 2

    Procedures for issuance and controls of documents are not followed. 1. QA issues duplicate equipment use logs and cleaning logs with the same issuance number. These duplicate logs are used in creation of records that document activities that did not occur. QA subsequently reviews and approves both sets of contradictory records. 2. The QC laboratory keeps uncontrolled notebooks which contain measurements associated with assay, LOD, pH, …

    Contains “QC laborator*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about laboratory controls in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.