Cross-contamination and mix-ups in FDA Form 483 observations
Keeping products, materials and potent or hazardous drugs apart: segregation, containment, dedicated equipment, penicillin and beta-lactams, and mix-ups. FDAgent finds 119 such observations in 96 Form 483s issued to 92 facilities, for inspections that ended between April 2014 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 119
- Each quoted below
- Form 483s
- 96
- Posted by FDA
- Facilities
- 92
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 39 in 2026
| Year | Observations |
|---|---|
| 2014 | 2 |
| 2015 | 3 |
| 2016 | 3 |
| 2017 | 7 |
| 2018 | 13 |
| 2019 | 10 |
| 2020 | 5 |
| 2021 | 14 |
| 2022 | 3 |
| 2023 | 3 |
| 2024 | 4 |
| 2025 | 13 |
| 2026 | 39 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.42(d)21 CFR 211.46(d)
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“cross contaminat*” · “crosscontaminat*” · “hazardous drug*” · “beta lactam*” · “penicillin*” · “cephalosporin*” · “mix up*” · “mixup*” · “segregation” · “not segregated” · “containment” · “dedicated equipment” · “dedicated area*” · “non dedicated”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 119 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 5
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. The following discrepancies were noted during review of the aseptic filling lines for the following: (b)(4) API (b)(4) 1. On April 9, 2026, I observed your firm failed to maintain equipment in a clean and orderly manner. The (b)(4) Sterile (b)(4) equipment (b)(4) was found to have the following …
Contains “mix up*”Read the Form 483 →
Pharmaneek IncInspection ended Apr 8, 2026 · FEI 3014484244 · Observation 1
Hazardous drugs were produced without providing adequate containment segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, The current cleaning process is deficient for the following reasons and does not provide assurance that hazardous drug product residue and cleaning agent residue are adequately removed from reusable glassware and utensils used in production of both …
Contains “hazardous drug*”Read the Form 483 →
ChemPacific CorporationInspection ended Apr 7, 2026 · FEI 3003299802 · Observation 3
… The presence of this unidentified, failed research and development material in the same storage unit as approved GMP intermediates creates a risk of cross-contamination or mix-up between rejected materials and materials intended for use in drug product manufacturing.
Contains “cross contaminat*”Read the Form 483 →
Conroe Welding Supply, IncInspection ended Apr 3, 2026 · FEI 1625647 · Observation 1
… was observed on batch records that the filler, tester, and product release approver were the same person, demonstrating a lack of independent verification and segregation of duties, as shown on batch records dated (b) (4) (lot (b) (4)), (b) (4) (lots (b) (4)), (b) (4) (lot (b) (4)), (b) (4) (lots (b) (4) (b) (4)), and (b) (4) (lots (b) (4)). Your firm distributed these lots to customers. C. Your firm failed to provide cGMP training to employees …
Contains “segregation”Read the Form 483 →
Adimmune CorporationInspection ended Apr 2, 2026 · FEI 3008919998 · Observation 1
Your firm failed to follow written procedures designed to prevent mix-up of drug products, specifically: During the inspection of the product (b) (4) conducted on March 27, 2026, it was observed, in (b) (4) Building (b) (4), final fill and finish (b) (4) of drug products displaying (b) (4) labels were stored in the (b) (4) area instead of the designated (b) (4) area as required by established procedures [SOP (b) (4) (b) (4) 010 Procedure of (b) …
Contains “mix up*”Read the Form 483 →
Fujifilm Diosynth Biotechnologies USA Inc.Inspection ended Mar 27, 2026 · FEI 3000718852 · Observation 1
Facility design and procedural controls for manufacturing drug substance intended for commercial distribution do not provide adequate assurance against microbial contamination and cross-contamination risks in the manufacturing suite at your Fujifilm Diosynth Biotechnologies USA Durham facility. Specifically, A. Your firm has failed to establish a facility cleaning and sanitization program that effectively prevents microbial contamination in drug …
Contains “cross contaminat*”Read the Form 483 →
Cerovene Inc.Inspection ended Mar 23, 2026 · FEI 3005890568 · Observation 1
… On 03/16/2026, presence of white caked residue was observed in Capsule Machine ID #(b) (4) (Non-dedicated) product contact surfaces including cavities for encapsulation and Capsule (b) (4) ID #(b) (4). The equipment is located in Room #”* (Capsule Machine Room) and was cleaned for type «Planing (Major cleaning) on (b) (4) after manufacturing (b) (4) Capsules USP, (b) (4) Batch #(b) (4) on (b) (4), and the equipment was issued a “Cleaned” status. …
Contains “non dedicated”Read the Form 483 →
Cerovene Inc.Inspection ended Mar 23, 2026 · FEI 3005890568 · Observation 2
OBSERVATION 2 (Repeat) Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, A. Per your VP of Operations, your firm does not review data, audit trails and alarm reports generated by the HMI ((b) (4)) of your non-dedicated (b) (4) Mixer (b) (4) ID# (b) (4). Operators that use this equipment …
Contains “non dedicated”Read the Form 483 →
Bausch and Lomb IncorporatedInspection ended Mar 20, 2026 · FEI 1000113778 · Observation 3
… There is no assurance that materials received have been placed in the correct location as assigned in your inventory system to prevent product mix-ups.
Contains “mix up*”Read the Form 483 →
Protein Sciences CorporationInspection ended Mar 17, 2026 · FEI 3011286996 · Observation 1
… Your firm does not physically [illegible] identity is determined by the [illegible] identify individual (b)(4) (b)(4) (b)(4) posing a risk to mix-up of (b)(4) identification. Your firm's primary method of identifying location of master or working cell or virus bank (b)(4) via an uncontrolled spreadsheet refers to (b)(4) identifiers [illegible] for vial location. Written procedure titled Management of Seed Lots and Cell Banks", QU-(b)(4)-0000136, …
Contains “mix up*”Read the Form 483 →
Protein Sciences CorporationInspection ended Mar 17, 2026 · FEI 3011286996 · Observation 3
… the frequency of sporicidal cleaning was increased, no corrective actions have been implemented to address the fundamental deficiency in material flow and segregation.
Contains “segregation”Read the Form 483 →
Hospira, Inc.Inspection ended Mar 10, 2026 · FEI 1925262 · Observation 4
… Your procedure, SOP 95112, “Gowning Procedure for Controlled Class IV/ Grade D Areas” v43, Effective date 25 August 2025 fail to prevent cross-contamination in Gowning Room gq for the gq fill line used in drug product manufacture. Your firm has not established a maximum occupancy limit for the gowning room or implemented restrictions to prevent simultaneous gowning and degowning activities. On 3 March 2026, at approximately personnel were …
Contains “cross contaminat*”Read the Form 483 →
Accura-Pac, Inc.Inspection ended Mar 5, 2026 · FEI 1818911 · Observation 3
… no controls in place to record how many hours the tanks have been in “dirty” status, or to ensure that the (B) (4) dirty hold time is not exceeded to prevent cross-contamination.
Contains “cross contaminat*”Read the Form 483 →
Accura-Pac, Inc.Inspection ended Mar 5, 2026 · FEI 1818911 · Observation 5
All compounding and storage containers used during the production of a batch of drug product is not properly identified at all times to indicate contents. Specifically, Your firm failed to establish adequate controls and procedures to prevent mix-ups of (b) (4) tankers used in the manufacture of OTC aerosol drug product. During the facility walkthrough, P@O@ tankers (tank numbers ®)@) © (bo) (4) were observed parked on the ®® tanker lot. The …
Contains “mix up*”Read the Form 483 →
GSK Vaccines GmbHInspection ended Feb 27, 2026 · FEI 3001314775 · Observation 1
Your firm has not validated the cleaning procedures for dedicated equipment used in the manufacture of Aluminum Hydroxide adjuvant to prevent contamination or carry-over. This adjuvant is a component of your licensed U.S. products including (b)(4) Infanrix, Boostrix, Kinrix, and Pediarix. Specifically, your cleaning validation and monitoring program for the aluminum hydroxide adjuvant production suite ((b)(4) and (b)(4)) is inadequate. You have …
Contains “dedicated equipment”Read the Form 483 →
Orean Personal Care LtdInspection ended Feb 20, 2026 · FEI 3010999645 · Observation 1
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, you manufacture Over the Counter (OTC) drug products for the US market on non-dedicated manufacturing equipment. You designed a cleaning matrix that identified most difficult product to clean, (b)(4) FDA product Code No. (b)(4) also called (b)(4). You did …
Contains “non dedicated”Read the Form 483 →
Almon Healthcare Private LimitedInspection ended Feb 13, 2026 · FEI 3030509366 · Observation 9
Failure to adequately validate written procedures for the cleaning and maintenance of equipment. Your firm has not performed cleaning validation studies for non-dedicated manufacturing equipment (b)(4) including (b)(4). Your firm manufactures APIs including (b)(4) (b)(4) (b)(4) for the US market. Your Executive QA stated that the cleaning verification was carried out with rinse samples and swab testing of the selected equipment, however cleaning …
Contains “non dedicated”Read the Form 483 →
Centrient Pharmaceuticals India Private LimitedInspection ended Jan 27, 2026 · FEI 3004497364 · Observation 1
Failure to clean equipment and utensils to prevent contamination or carry-over of a material that would alter the quality of the intermediates and Active Pharmaceutical Ingredient beyond the official or other established specifications. Specifically, The (b)(4) used at the (b)(4) stages of APIs manufacturing have not been non-dedicated (b)(4) appropriately cleaned since their installation 27+ years ago. For example, A. On 19 and 20 January 2026, …
Contains “non dedicated”Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 10
… hold times for equipment, including, but not limited to, the Mixing Machine (b) (4), used to manufacture both dietary supplements and drug products to prevent cross-contamination as required per SOP-26 "Cleaning Validation". On 01/09/2026, the (b) (4) for OTC drug product (b) (4) (no lot number was listed in the usage and cleaning logbook) was blended in Mixing Machine (b) (4) following the blending of dietary supplement (b) (4) on the same …
Contains “cross contaminat*”Read the Form 483 →
Eugia Pharma Specialities LimitedInspection ended Nov 14, 2025 · FEI 3009883410 · Observation 9
… This deficiency does not ensure directional flow of the cleaning activities to prevent a potential cross contamination between uncleaned and cleaned zones. Furthermore, when reviewing the cleaning process for (b) (4) Injection USP (b) (4) g/vial, Batch: (b) (4) (USA market), your operator was observed placing an uncleaned (b) (4) stand (used for Environmental Monitoring activities) directly onto the conveyor belt that had been previously cleaned. …
Contains “cross contaminat*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.42Design and construction featuresIn this theme's rule15
- 21 CFR 211.67Equipment cleaning and maintenance12
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1
- 21 CFR 211.105Equipment identification1
- 21 CFR 211.165Testing and release for distribution1
- 21 CFR 211.192Production record review1
Ask FDAgent about cross-contamination and mix-ups in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.