Skip to content

H & P Industries, Inc.

700 W North Shore Dr, Hartland, Wisconsin, United States

FEI 2128643

FDA has 9 inspections on file for H & P Industries, Inc. in Hartland, Wisconsin (FEI 2128643), from 2009 to 2011. The latest ended on and was classified OAI, official action indicated. FDA has also posted a Form 483 dated Jul 23, 2015 that FDAgent has not matched to an inspection on the Data Dashboard.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 10 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

FDA issued a warning letter on (CDER). FDA's compliance record also lists 2 other actions under this FEI, the latest Injunction, . No import refusal is filed under this FEI.

25 regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
9, 2009–2011
4 OAI · 3 VAI · 2 NAI
Inspections with 483 observations shown
8 of 9
7 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
7 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  5. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  6. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  7. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  8. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Cleaning SOPs/schedules

      Procedures for the cleaning and maintenance of equipment are deficient regarding maintenance and cleaning schedules, including, where appropriate, sanitizing schedules.

    2. Drains--Size, Back-siphonage Prevention

      Drains are not provided with an air break or other mechanical device to prevent back-siphonage where connected directly with a sewer.

    3. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that components conform to appropriate standards of identity, strength, quality and purity.

    4. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    5. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.

    Show 5 more citations
    1. Equipment for Environmental Control

      Equipment for adequate control over air pressure and dust is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.

    2. Buildings not maintained in good state of repair

      Buildings used in the manufacturing of a drug product are not maintained in a good state of repair.

    3. Extent of discrepancy, failure investigations

      Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.

    4. Cleaning/maintenance records not kept

      Records are not kept for the sanitizing of equipment.

    5. Written procedures not established/followed

      Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

  9. OAISignificant objectionable conditions; FDA recommended regulatory actionDevices · Compliance: Devices44 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lot or control number assigned

      The drug product is not identified with a lot or control number that permits the determination of the history of the manufacture and control of the batch.

    2. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    4. Quarantine - actual practice

      Drug products are not quarantined before being released by the quality control unit.

    5. Extent of discrepancy, failure investigations

      Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.

    Show 39 more citations
    1. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

    2. Plumbing System Defects

      The plumbing system contains defects that could contribute to the contamination of drug products.

    3. Written program not followed

      The written stability testing program is not followed.

    4. Failing drug products not rejected

      Drug products failing to meet established specifications are not rejected.

    5. Sample identification and other information

      Laboratory records do not include the lot number or other distinctive code of the sample.

    6. Training , Education , Experience overall

      Employees engaged in the processing and holding of a drug product lack the education required to perform their assigned functions.

    7. Supervisor Training/Education/Experience

      Individuals responsible for supervising the processing and holding of a drug product lack the education to perform their assigned functions in such a manner as to assure the drug product has the safety, identity, strength, quality and purity that it purports or is represented to possess.

    8. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices, and written procedures required by current good manufacturing practice regulations.

    9. Actual vs. theoretical yields not determined

      Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing of the drug product.

    10. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    11. Contamination control, Lack of or inadequate procedures

      Procedures to prevent contamination of equipment or product by substances that may have an adverse effect on product quality have not been adequately established.

    12. Following/documenting laboratory controls

      Established sampling plans are not followed.

    13. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

    14. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.

    15. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.

    16. Results not used for expiration dates, storage cond.

      Results of stability testing are not used in determining expiration dates.

    17. Items to cover on annual reviews

      Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.

    18. Written warehousing procedures established/followed

      Procedures describing the warehousing of drug products are not established and followed.

    19. Lack of or inadequate procedures

      Procedures for corrective and preventive action have not been established.

    20. Approve or reject components, products

      The quality control unit lacks the responsibility and authority to approve all drug products.

    21. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    22. Lack of or inadequate final acceptance procedures

      Procedures for finished device acceptance have not been established.

    23. Inadequate number of personnel

      The number of qualified personnel is inadequate to perform and supervise the manufacture, processing, packing, and holding of each drug product.

    24. In-process materials specifications testing

      Examination and testing of samples is not done to assure that in-process materials conform to specifications.

    25. Lack/Inad procedure-Monitoring/Control of Validated Proces

      Procedures for monitoring and control of process parameters for a validated process have not been adequately established.

    26. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    27. Control procedures fail to include the following

      Control procedures fail to include adequacy of mixing to assure uniformity and homogeneity.

    28. Distinctive ID or code not recorded in batch record

      The batch records do not record the distinctive identification number to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.

    29. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not recorded and justified.

    30. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    31. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.

    32. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    33. Control procedures to monitor and validate performance

      Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    34. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.

    35. Deviations from laboratory control requirements

      Deviations from written specifications and sampling plans are not justified.

    36. Lack of or inadequate process validation

      A process whose results cannot be fully verified by subsequent inspection and test has not been validated according to established procedures.

    37. SOPs not followed / documented

      Written production and process control procedures are not documented at the time of performance.

    38. Signature and checking of records -- 2 persons

      The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.

    39. Purchasing controls, Lack of or inadequate procedures

      Procedures to ensure that all purchased or otherwise received product and services conform to specified requirements have not been established.

  10. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  11. NAINo objectionable conditions that need follow-upDrugs · Drug Quality Assurance18 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Individual inventory record

      Records fail to include an individual inventory record of each component and reconciliation of the use of each component with sufficient information to allow determination of any associated batch or lot of drug product.

    2. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    4. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    5. Buildings not maintained in good state of repair

      Buildings used in the manufacturing, processing, packing, and holding of a drug product are not maintained in a good state of repair.

    Show 13 more citations
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    2. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    3. Review of representative number of batches

      Written procedures are not established and followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    4. Record maintenance 1 year (except exempt OTC)

      All records of production associated with a batch of drug product are not maintained at least one (1) year after the expiration date.

    5. Failing drug products not rejected

      Drug products failing to meet established specifications are not rejected.

    6. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    7. Extent of discrepancy, failure investigations

      Investigations of an unexplained discrepancy did not extend to other drug products that may have been associated with the specific failure or discrepancy.

    8. Failure to meet specifications

      An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning a failure of one or more distributed batches of a drug to meet the specifications established for it in the application.

    9. Written program not followed

      The written stability testing program is not followed.

    10. Responsible firm officials notified in writing

      Procedures are not established which are designed to assure that the responsible officials of the firm, if they are not personally involved in or immediately aware of such actions, are notified in writing of investigations conducted, recalls, reports of inspectional observations issued by FDA, and any regulatory actions brought by FDA relating to good manufacturing practices.

    11. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    12. Calibration/Inspection/Checking not done

      Routine inspection and checking of automatic equipment is not performed according to a written program designed to assure proper performance.

    13. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

  12. OAISignificant objectionable conditions; FDA recommended regulatory actionDevices · Compliance: Devices25 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used and description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance.

    2. Complete test data included in records

      Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

    3. Approval and review of procedures

      Written procedures are not drafted, reviewed and approved by the appropriate organizational units.

    4. Deviations from laboratory control requirements

      Deviations from written specifications are not justified.

    5. Written program not followed

      The written stability testing program is not followed.

    Show 20 more citations
    1. Results not used for expiration dates, storage cond.

      Results of stability testing are not used in determining expiration dates.

    2. Training , Education , Experience overall

      Employees engaged in the manufacture and packing of a drug product lack the training required to perform their assigned functions.

    3. Failing drug products not rejected

      Drug products failing to meet established specifications are not rejected.

    4. Lack of Written MDR Procedures

      Written MDR procedures have not been developed and implemented.

    5. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    6. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.

    7. Written procedures not established/followed

      Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    8. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

    9. Documentation

      Corrective and preventive action activities and/or results have not been adequately documented.

    10. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions.

    11. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.

    12. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

    13. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    14. Procedures for product review,disposition lack of/inadequate

      Procedures that define the responsibility for review and the authority for the disposition of nonconforming product have not been adequately established.

    15. Extent of discrepancy, failure investigations

      Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product.

    16. Initial Submission of Baseline Report

      A baseline report on FDA Form 3417 or approved electronic equivalent was not submitted following the first MDR report on a device model.

    17. Lack of or inadequate process validation

      A process whose results cannot be fully verified by subsequent inspection and test has not been adequately validated according to established procedures.

    18. Lack of or inadequate final acceptance procedures

      Procedures for finished device acceptance have not been adequately established.

    19. Reprocessing/quality control unit

      Reprocessing was performed without the review of the quality control unit.

    20. Investigation of device failures

      Complaints involving the possible failure of a device and labeling to meet any of its specifications were not evaluated and investigated where necessary.

  13. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions that would alter the safety, identity, strength, quality or purity of the drug product.

    2. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    3. Inadequate number of personnel

      The number of qualified personnel is inadequate to perform and supervise the processing and packing of each drug product.

  14. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance21 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Failing drug products not rejected

      Drug products failing to meet established specifications are not rejected.

    2. Written procedures not established/followed

      Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    3. Written warehousing procedures established/followed

      Procedures describing the warehousing of drug products are not followed.

    4. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.

    5. Identification of containers, lines, equipment

      All major equipment used during the production of a batch of drug product is not properly identified at all times to indicate contents.

    Show 16 more citations
    1. Instruments, apparatus, et. al. not meeting specs

      The use of instruments not meeting established specifications was observed.

    2. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.

    3. Test methods

      The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented.

    4. GMP Training Frequency

      GMP training is not conducted with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.

    5. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    6. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    7. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used and description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance.

    8. Written calibration / inspection records not kept

      Records of the inspections of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.

    9. Reprocessing/quality control unit

      Reprocessing was performed without the approval of the quality control unit.

    10. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    11. Rejected in-process materials not quarantined

      Rejected in-process materials are not identified and controlled under a quarantine system to prevent their use in manufacturing or processing operations for which they are unsuitable.

    12. Deviations from laboratory control requirements

      Deviations from written specifications are not justified.

    13. Representative Samples Criteria

      The number of containers to be sampled is not based upon appropriate criteria.

    14. Strict control not exercised over labeling issued

      Strict control is not exercised over labeling issued for use in drug product labeling operations.

    15. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    16. Extent of discrepancy, failure investigations

      Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product.

  15. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures are written, and followed

      Procedures designed to assure that correct labeling and packaging materials are used for drug products are not followed.

  16. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Items to cover on annual reviews

      Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints and investigations conducted for each drug product.

    2. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    3. Buildings not maintained in good state of repair

      Buildings used in the manufacturing of a drug product are not maintained in a good state of repair.

    4. Reprocessing procedures not written or followed

      Procedures prescribing a system for reprocessing batches to insure that the reprocessed batches will conform with all established standards, specifications, and characteristics are not followed.

    5. Failing drug products not rejected

      Drug products failing to meet established specifications are not rejected.

    Show 2 more citations
    1. Extent of discrepancy, failure investigations

      Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product.

    2. Written program not followed

      The written stability testing program is not followed.

Regulations FDA cited here

The 38 sections of 21 CFR in FDA’s published citations for 8 of this facility’s 9 inspections, with how many of them cited each.

Show all 38

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • InjunctionCDER · DrugsFDA record
  • SeizureCDER · DrugsFDA record
  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 2128643 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 2128643. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.