Stability testing and expiration dating in FDA Form 483 observations
Stability programs and the data behind expiration dates and shelf lives: studies, protocols, samples, chambers and time points. FDAgent finds 159 such observations in 114 Form 483s issued to 112 facilities, for inspections that ended between June 2012 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 159
- Each quoted below
- Form 483s
- 114
- Posted by FDA
- Facilities
- 112
- Distinct FEIs
- Most recent
- Sep 10, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 44 in 2026
| Year | Observations |
|---|---|
| 2012 | 4 |
| 2013 | 2 |
| 2014 | 2 |
| 2015 | 2 |
| 2016 | 5 |
| 2017 | 11 |
| 2018 | 11 |
| 2019 | 9 |
| 2020 | 0 |
| 2021 | 2 |
| 2022 | 9 |
| 2023 | 18 |
| 2024 | 14 |
| 2025 | 26 |
| 2026 | 44 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
The same entries the stability topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“stability stud*” · “stability test*” · “stability program*” · “stability data” · “stability protocol*” · “stability sample*” · “stability chamber*” · “stability indicating” · “stability batch*” · “stability time point*” · “stability pull*” · “stability failure*” · “stability result*” · “ongoing stability” · “expiration dat*” · “expiry dat*” · “expiry period*” · “shelf life”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 159 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Apotex Research Private LimitedInspection ended Mar 15, 2024 · FEI 3006076314 · Observation 3
… During the review of the degradation results of Batch (b) (4) (Stability Sample, RT (b) (4)) you failed to inject the Solution (b)(4) (system suitability solution) injection at the beginning of the sequence injections as a part of system suitability criteria per method degradation product (b) (4). Solution (b)(4) (system suitability solution) was injected and analyzed in separate chromatographic sequence. C) The Quality Unit failed to establish …
Contains “stability sample*”Read the Form 483 →
Medimmune U.K. LimitedInspection ended Mar 15, 2024 · FEI 3004066112 · Observation 2
Inadequate data for the qualification of the (b)(4) positive control used for the (b)(4) assay to monitor the (b)(4) level of the (b)(4) fluid in the (b)(4). a. Lack of stability data to support the shelf-life of the (b)(4) positive control ((b)(4). b. No data to support that the (b)(4) of the (b)(4) positive control has no interference effect on the assay.
Contains “stability data”Read the Form 483 →
GSK Vaccines GmbHInspection ended Mar 6, 2024 · FEI 3001314775 · Observation 4
Documents and (b) (4) used for distribution of the (b) (4) drug products are deficient. Specifically, your firm failed to ensure correct (b) (4) were applied to (b) (4) drug product containers before release. The final (b) (4) on your containers that hold (b) (4) drug products contain incorrect expiration date. The expiration date on the (b) (4) was not based on the associated stability studies. Furthermore, your documentations that accompanied …
Contains “expiration dat*”Read the Form 483 →
Fukuzyu Pharmaceutical Co., Ltd.Inspection ended Jan 19, 2024 · FEI 3002807025 · Observation 2
… the cleaning validation report for PYR-2015-02 using the linearity, LOQ, and range data from the first set of standard solutions combined with the solution stability data from the second set of standard solutions. There was no investigation, no scientific justification to accept data from standards that failed stability, and no written justification to accept sample stability that did not meet the acceptance criteria. Your firm relies on cleaning …
Contains “stability data”Read the Form 483 →
Titan Kogyo, LtdInspection ended Dec 8, 2023 · FEI 3009155994 · Observation 2
The firm's stability program was inadequate in that the firm's QC Laboratory failed to utilize a stability indicating method for assay testing of (b) (4) The QC Laboratory utilizes a titration method for assay testing of (b) (4) for all stability testing that the firm has conducted on their (b) (4) API products including the following US marketed API: (b) (4) For example, the firm utilized the titration assay method for the accelerated stability …
Contains “stability program*”Read the Form 483 →
Alkem Laboratories LimitedInspection ended Dec 1, 2023 · FEI 3008450172 · Observation 2
… B- Excursions for Stability Chamber / Cooling Chamber / Deep Freezer are documented on M-QC/0173-F0002-000 under Standard Operating Procedure, M-QC/0173-004, documented titled, 'Operation and Monitoring of Stability Chamber, Cooling Chamber and Deep Freezer (Make: Newtronic) through ICDAS v2.1 Software', with effective date June 1, 2022. On November 29, 2023, I observed 2 excursion reports that are not fully documented. 1- Report for stability …
Contains “stability chamber*”Read the Form 483 →
Antaria Pty Ltd.Inspection ended Nov 17, 2023 · FEI 3025978151 · Observation 1
… These reports were approved by QA however, the lack of stability studies and stability data for 2020 and 2021 did not trigger an investigation. e) Your firm is not following SOP 206.113 Brisbane Stability Oven Operation, Rev 0 issued 08AUG2022 regarding (b) (4) downloading and review of the temperature and humidity readings from the data loggers for the stability chambers. The data loggers reached their maximum storage capacity on October 6, 2022 …
Contains “stability stud*”Read the Form 483 →
Antaria Pty Ltd.Inspection ended Nov 17, 2023 · FEI 3025978151 · Observation 4
Your firm does not assign an expiration date for prepared working standards, mobile phases, diluents and other preparations used for performing testing of drug products, including (b) (4) API. Test methods include testing for assay, elemental impurities, and other required USP tests. For example, the bottle of working standard (b) (4) ug/mL (b) (4) standard solution) that is currently being used for assay by (b) (4) chromatography is marked with …
Contains “expiration dat*”Read the Form 483 →
Antaria Pty Ltd.Inspection ended Nov 17, 2023 · FEI 3025978151 · Observation 5
There is no written testing program designed to assess the stability characteristics of drug products. Specifically, your firm has not placed at least one lot of (b) (4) API (b) (4) on stability annually. For example, you currently have (b) (4) lots on long term stability; (b) (4) lot placed on stability in 2022 and (b) (4) in 2023. No lots have been placed on stability for product manufactured at the Brisbane site in 2019, 2020, or 2021. In …
Opens with FDA's citation wording for 21 CFR 211.166(a)Read the Form 483 →
Antaria Pty Ltd.Inspection ended Nov 17, 2023 · FEI 3025978151 · Observation 8
Your firm has no documentation to show the test methods used for stability testing of (b) (4) USP (API) and other drug products are stability indicating.
Contains “stability test*”Read the Form 483 →
Antaria Pty Ltd.Inspection ended Nov 17, 2023 · FEI 3025978151 · Observation 9
Your firm has not fully qualified the stability chambers used for long term (30C/65%RH - Oven ID O-0007) and accelerated stability studies. The chambers were installed in April 2022. The Operational Qualification (OQ) report approved on August 15, 2022 by QA contains no information about the actual operation of the chambers including no temperature and humidity readings, no verification documentation that the digital read out of the temperature …
Contains “stability chamber*”Read the Form 483 →
Jiangsu Intco Medical Products Co., LtdInspection ended Nov 17, 2023 · FEI 3005260401 · Observation 2
There is no written testing program designed to assess the stability characteristics of drug products. Specifically, Your firm’s stability program is deficient. For example: (a) You did not maintain batch production [illegible] to support your stability testing used to establish the expiration date for your OTC liquid [illegible] and OTC [illegible]. The following batches were used for your accelerated and long-term stability study, however your …
Opens with FDA's citation wording for 21 CFR 211.166(a)Read the Form 483 →
Catalent Indiana, LLCInspection ended Nov 15, 2023 · FEI 3005949964 · Observation 2
… The investigation for complaint #764722 is inadequate in that the expiry date for project code (6) (4) lot #.( ]1)] was not documented nor were retain samples inspected.
Contains “expiry dat*”Read the Form 483 →
Sumitomo Osaka Cement Co., LtdInspection ended Oct 27, 2023 · FEI 3003943727 · Observation 4
… and DV22003 was initiated for excursions in humidity (74%) for (b)(4) and for temperature and humidity (35.8C and 70.4% RH) for (b)(4) in the 25C/60%RH stability chamber. However, no CAPA was initiated. 5. The analytical method for the raw material (b)(4) used in the manufacturing of (b)(4) API is not verified. The firm does not perform testing of assay and instead confirm assay with the COA of supplier to ensure if the results meet the firms' …
Contains “stability chamber*”Read the Form 483 →
Linhai Tianyu Pharmaceutical Co., Ltd.Inspection ended Sep 15, 2023 · FEI 3013345425 · Observation 3
… contaminated with (b) (4)" -On or around 01/01/2022, OOS-10501-22001 was initiated for drug substance (b) (4) (b) (4) batch number (b) (4) 6-month accelerated stability test for (b) (4) impurity (b) (4) with result as (b) (4) ppb versus a specification of LOD (4) ppb. Your firm's investigation determined the root cause to be "the bottle cap used for the test did not differentiate between the use of samples and controls, and the tester got the (b) …
Contains “stability test*”Read the Form 483 →
Linhai Tianyu Pharmaceutical Co., Ltd.Inspection ended Sep 15, 2023 · FEI 3013345425 · Observation 5
There is no written testing program designed to assess the stability characteristics of drug substances and intermediates. Specifically, the assay and related substance test methods for intermediate (b) (4) used for stability testing are not stability indicating, where they can detect the change with time in chemical, physical or microbiological properties of the intermediate drug substance so that the content of active ingredients and …
Contains “stability test*”Read the Form 483 →
Wickliffe LLCInspection ended Sep 15, 2023 · FEI 3002992930 · Observation 6
There is no written testing program designed to assess the stability characteristics of drug products. Specifically, Batches are not put on stability that have been prescribed for office stock. Products prescribed for office stock include Doxycycline Hyclate in Oil Suspension 500mg/mL and Methimazole Suspension 2.5mg/mL. Potency over time or (b) (4) is tested for new sterile products, however, other drug quality attributes are not evaluated under …
Opens with FDA's citation wording for 21 CFR 211.166(a)Read the Form 483 →
Nortec Quimica S.A.Inspection ended Aug 4, 2023 · FEI 3007616930 · Observation 1
… ingredient (API), (b) (4) were manufactured after the worst case scenario API, (b) (4) was discounted for (b) (4) Product Lot Manufacturing Date Expiration Date (b) (4)
Contains “expiration dat*”Read the Form 483 →
Ipca Laboratories LimitedInspection ended Jun 23, 2023 · FEI 3007574780 · Observation 1
… (b) (4) (result %, Stability Sample 25 ± 2 (b) (4) ((b) (4) Tablet mg, non-US market) (result 9 month) and Batch No. (b) (4) (b) (4) Stability Sample 25 ± 2℃/60 ± 5 %RH, 3 month) against the Specification. You tested the sample using test procedure, STP No. TP/AS/0950/00 Assay (By HPLC) for Tablets, Effective date 10/25/2019, in line with your analytical method validation report, AMV/R/2017/010/00, Effective date 8/23/2017. In the Phase IA of the …
Contains “stability sample*”Read the Form 483 →
Ipca Laboratories LimitedInspection ended Jun 23, 2023 · FEI 3007574780 · Observation 3
… Your firm has been using the UV methods without system suitability established to test the dissolution of the (b) (4) drug products for batch release and stability study since each the Agency (refer to the table below). Without demonstrating system suitability, all the dissolution data analyzed by the UV method for the commercial and exhibit batches of your (b) (4) corresponding batches may not be reliable. Among the (b) (4) approved and are …
Contains “stability stud*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.166Stability testingIn this theme's rule21
- 21 CFR 211.192Production record review15
- 21 CFR 211.22Responsibilities of quality control unit6
- 21 CFR 211.100Written procedures; deviations6
- 21 CFR 211.137Expiration datingIn this theme's rule4
- 21 CFR 211.113Control of microbiological contamination3
- 21 CFR 211.160General requirements3
- 21 CFR 211.42Design and construction features2
- 21 CFR 211.170Reserve samples2
- 21 CFR 211.28Personnel responsibilities1
Ask FDAgent about stability in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.