Skip to content

Compounding pharmacies and outsourcing facilities in FDA Form 483 observations

Observations at pharmacies and 503B outsourcing facilities that compound drugs: beyond-use dates, patient-specific prescriptions and compounding practices. FDAgent finds 268 such observations in 114 Form 483s issued to 105 facilities, for inspections that ended between November 2012 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
268
Each quoted below
Form 483s
114
Posted by FDA
Facilities
105
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 71 in 2026

Compounding observations in Form 483s by inspection year
YearObservations
20121
20132
20146
20157
201610
201715
201827
201934
20208
202130
202221
202313
20249
202514
202671

How FDAgent sorts observations into this theme

One fixed rule, applied by code to every observation FDAgent can quote. No model and no similarity score decides.

Its text contains one of these phrases

“compounded” · “compounding” · “compounder*” · “503A” · “503B” · “outsourcing facilit*” · “pharmacist*” · “pharmacy” · “pharmacies” · “beyond use dat*” · “BUD*” · “USP 797” · “patient specific” · “prescription*”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 268 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. RC Outsourcing LLCInspection ended Sep 3, 2026 · FEI 3011967886 · Observation 1

    … This deficiency, compounded by unresolved sterility failures and incomplete investigation findings, raises significant concerns regarding your firm's ability to assure the sterility of its aseptically re-packaged drug product. D. The following inadequate aseptic technique behaviors were observed: i. Your procedure, SOP 65, Maintaining Sterile Environment, effective 04/08/2026, is deficient. For example, per this procedure, your sterile gloving …

    Contains “compounded”Read the Form 483 →

  2. RC Outsourcing LLCInspection ended Sep 3, 2026 · FEI 3011967886 · Observation 8

    Drug product expiration dates are not related to the storage conditions stated on the labeling, as determined by stability studies. Specifically, Your firm's product labels do not specify required storage temperature conditions, and the assigned beyond-use date (BUD) is not supported by stability testing. For example: your firm has failed to specify required storage temperature conditions on product labels, despite assigning a beyond-use date …

    Contains “beyond use dat*”Read the Form 483 →

  3. OPS International Inc dba Olympia PharmaceuticalsInspection ended Sep 3, 2026 · FEI 3009724085 · Observation 5

    The written stability program for drug products does not include reliable, meaningful and specific test methods. Specifically, your firm assigns a (b)(4) beyond-use date (BUD) to Sermorelin Acetate 0.9 mg/mL Injection based on your contract laboratory stability study. However, your firm failed to provide adequate demonstration that the analytical procedure can detect relevant degradation-related changes. Your method validation report for …

    Contains “beyond use dat*”Read the Form 483 →

  4. OPS International Inc dba Olympia PharmaceuticalsInspection ended Sep 3, 2026 · FEI 3009724085 · Observation 7

    … lot was used in the production of T-105 Injection (Papaverine Hydrochloride 30 mg/mL; Phentolamine Mesylate 1 mg/mL; Alprostadil 0.01 mg/mL), Lot #G08A10-26, BUD 04 JUL 2027. (C) Your firm failed to test each container of each lot of glycerin, used as a pharmaceutical ingredient, for diethylene glycol (DEG) or ethylene glycol (EG) contamination. Your firm did not provide a scientifically sound justification, supported by statistical analysis, for …

    Contains “BUD*”Read the Form 483 →

  5. Houston Rx LLCInspection ended Aug 28, 2026 · FEI 3045022201 · Observation 8

    … During a media fill, per your Quality Assurance/Compliance Pharmacy Technician, your firm fills (b)(4) vials. Your firm takes prepared media from a vial, draws it into a (b)(4), and then fills the vials using the (b)(4). Your firm also does not document the number of vials filled, incubated and read in the paperwork for the media fills.

    Contains “pharmacy”Read the Form 483 →

  6. STAQ Pharma of Ohio LLCInspection ended Aug 19, 2026 · FEI 3025336457 · Observation 1

    Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Your firm's visual inspection qualification procedure for sterile injectable drug products compounded and packaged in syringes is inadequate to ensure that visual …

    Contains “compounded”Read the Form 483 →

  7. STAQ Pharma of Ohio LLCInspection ended Aug 19, 2026 · FEI 3025336457 · Observation 2

    … For example, for Succinylcholine Chloride 20 mg/mL, 10 mL in 10 mL syringe, Injection Batch 62116169A (batch size (b)(4) syringes, manufactured on (b)(4), BUD 10/30/2026), light intensity was measured during visual inspection, however, the batch record only documented whether the light intensity met the established acceptance criteria.

    Contains “BUD*”Read the Form 483 →

  8. STAQ Pharma of Ohio LLCInspection ended Aug 19, 2026 · FEI 3025336457 · Observation 3

    … Your firm's media fill program does not include worst-case conditions for all syringe sizes used in sterile compounding operations. No media fill has been performed for the (b)(4) syringe size ([illegible]) since 2024. Approximately, (b)(4) batches in (b)(4) syringes have been compounded and released since October 2025. For example, Sodium Chloride 9 mg/mL, (b)(4) in (b)(4) syringes, Injection Batch 62169152A (batch size (b)(4) syringes, BUD …

    Contains “compounding”Read the Form 483 →

  9. Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 1

    … of drug products, such as tirzepatide, are stored in unclassified areas and repeatedly introduced into the ISO-5 environment over a (b)(4) period to draw up patient-specific syringes. This workflow repeatedly exposes the bulk container closure system to unclassified air during storage and introducing contamination risks with each re-entry. You are using (b)(4). This can only inhibit bacterial proliferation; it is not bactericidal and does not …

    Contains “patient specific”Read the Form 483 →

  10. Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 2

    The Cleanroom areas contain dust-collecting overhangs without adequate and frequent cleaning. Specifically, on 08/05/2026, visible dust was observed on the inside of the clean room door windowpane adjacent to the (b)(4) ISO-5 (b)(4) laminar flow hood in the non-hazardous compounding cleanroom which is used to produce sterile non-hazardous drug products. Throughout the cleanroom suites, doors and viewing windows feature decorative molding with …

    Contains “compounding”Read the Form 483 →

  11. Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 4

    … This reprocessing was performed on (b)(4) and the beyond use date assigned was 9/19/2026.

    Contains “beyond use dat*”Read the Form 483 →

  12. Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 5

    … Compounding room (b)(4) contains (b)(4) ISO 5 biosafety cabinets positioned facing each other, approximately 2-3 feet apart. One hood is designated for nuclear blood tagging, and the other is used for the production of testosterone cypionate injectable product intended to be sterile. No smoke study has been conducted to demonstrate that the airflow from one hood does not interfere with the airflow of the other. The smoke study videos also did not …

    Contains “compounding”Read the Form 483 →

  13. Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 6

    … A door connects the warehouse / material receiving and shipping room directly to the non-sterile compounding processing and pharmacy orders packaging room. A door connects the warehouse to the employee break room and front hallway, administrative area, and compounding area front entrance. These doors from the warehouse lack controls to prevent cross contamination from the recycle room, warehouse, and mezzanine areas from being introduced to the …

    Contains “compounding”Read the Form 483 →

  14. Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 7

    Hazardous drugs and Highly potent drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. A. Specifically, testosterone compounding (a highly potent hormone), chemotherapy reconstitution (hazardous drugs), and blood radiolabeling (biohazardous material) are all performed within the same cleanroom (b)(4) using (b)(4) hoods in close …

    Contains “compounding”Read the Form 483 →

  15. Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 9

    Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted. Specifically, on 08/06/2026 during cleaning activities of the (b)(4) laminar flow hood ISO 5 (b)(4) in cleanroom (b)(4), the upper torso of a pharmacist was observed entering the ISO 5 hood, disrupting the unidirectional airflow intended to protect the sterile field.

    Contains “pharmacist*”Read the Form 483 →

  16. Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 10

    Vermin or other animals or evidence of their presence was observed in the areas adjacent to production areas. Specifically, on 08/05/2026, dead roaches were observed in the recycling room located at the back of the main warehouse, which is adjacent to areas with direct access to the compounding rooms. We observed each day of this inspection that bird feces were located on the ground outside your facility front door.

    Contains “compounding”Read the Form 483 →

  17. IntegraDose Compounding Services LLCInspection ended Aug 12, 2026 · FEI 3014483112 · Observation 1

    … Your firm did not restrict production activities in the affected areas or conduct an impact assessment on compounded drug products produced while these HEPA filters were displaying a red indicator light. C. On August 5, 2026, while reviewing video recordings of the production of Hydromorphone HCL 20mg/100mL CADDS lot #20260720HYD-1, EXP November 17, 2026, completed on (b)(4), it was observed there were up to [illegible] personnel present in …

    Contains “compounded”Read the Form 483 →

  18. IntegraDose Compounding Services LLCInspection ended Aug 12, 2026 · FEI 3014483112 · Observation 3

    … study did not evaluate this product placement configuration and therefore does not demonstrate that unidirectional airflow adequately protects the critical compounding area under actual production conditions. Additionally, during production, CADDs were observed blocking first air for components placed behind the CADDs and the connectors of the CADDs were observed resting on the back wall of the LAFH where the HEPA filter is located. This batch of …

    Contains “compounding”Read the Form 483 →

  19. IntegraDose Compounding Services LLCInspection ended Aug 12, 2026 · FEI 3014483112 · Observation 4

    … Your SOP-0015 Environmental Monitoring (EM) Program: 503B Cleanroom, states placement should be "(b)(4) from the back/HEPA filter." 2. Your firm does not document the time post production EM samples are taken.

    Contains “503B”Read the Form 483 →

  20. OurPharma LLCInspection ended Aug 12, 2026 · FEI 3014064135 · Observation 1

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, • (b)(4) Sterilization Performed in an ISO 8 Classified Room Batch records collected during the inspection confirm that (b)(4) sterilization was performed in Compounding Room (b)(4) which is classified as ISO 8. Specifically: Batch production records for two lots of Fentanyl …

    Contains “compounding”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about compounding in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.