Skip to content

Stability testing and expiration dating in FDA Form 483 observations

Stability programs and the data behind expiration dates and shelf lives: studies, protocols, samples, chambers and time points. FDAgent finds 159 such observations in 114 Form 483s issued to 112 facilities, for inspections that ended between June 2012 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
159
Each quoted below
Form 483s
114
Posted by FDA
Facilities
112
Distinct FEIs
Most recent
Sep 10, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 44 in 2026

Stability observations in Form 483s by inspection year
YearObservations
20124
20132
20142
20152
20165
201711
201811
20199
20200
20212
20229
202318
202414
202526
202644

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.16621 CFR 211.137

The same entries the stability topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“stability stud*” · “stability test*” · “stability program*” · “stability data” · “stability protocol*” · “stability sample*” · “stability chamber*” · “stability indicating” · “stability batch*” · “stability time point*” · “stability pull*” · “stability failure*” · “stability result*” · “ongoing stability” · “expiration dat*” · “expiry dat*” · “expiry period*” · “shelf life”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 159 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Linde Gas & Equipment Inc.Inspection ended Apr 1, 2026 · FEI 2523408 · Observation 1

    The firm failed to conduct thorough and adequate annual product reviews. Your document PD.OPS-0026, Revision 7, Internal Quality System Assessments and Product reviews, effective 2/2/2026, does not include specific requirements for conducting product-specific reviews of medical gases, including evaluation of batch records, testing results and stability data. Additionally, the 2023 - 2025 Quality Management reviews lacked Out-of-specification …

    Contains “stability data”Read the Form 483 →

  2. Linde Gas & Equipment Inc.Inspection ended Apr 1, 2026 · FEI 2523408 · Observation 2

    There is no written testing program designed to assess the stability characteristic of USP grade Air, and (b) (4) (b) (4) Specifically, Your firm has not established a stability program, nor have you performed stability studies to assess the stability characteristics of USP grade Air: (b) (4) as well as (b) (4). Currently you have manufactured, released and distributed approximately (b) (4) lots since 12/01/2025.

    Contains “stability program*”Read the Form 483 →

  3. Dendreon Pharmaceuticals LLCInspection ended Mar 25, 2026 · FEI 3008821247 · Observation 1

    … e) Non-conformance NC-25007 dated April 7, 2025, investigated the failure of (b) (4) samples from (b) (4) and (b) (4) that failed the (b) (4) stability test for density. The (b) (4) sample results were out of specification (OOS) for the required density range for (b) (4). The investigation concluded that the (b) (4) needed to be (b) (4) testing. New samples from the batches were tested for density, the results passed, and the conclusion stated …

    Contains “stability test*”Read the Form 483 →

  4. Dendreon Pharmaceuticals LLCInspection ended Mar 25, 2026 · FEI 3008821247 · Observation 7

    Drug product (b) (4) are (b) (4) so as to alter the safety, identity, strength, quality, and purity of the drug beyond the official or established requirements. Specifically, since February 2024, your firm started using (b) (4) for the in-house manufacturing of (b) (4) instead of (b) (4) (b) (4) which were used by the CMO's formulation. However, your stability study with (b) (4) in the (b) (4) position does not evaluate potential leachable, …

    Contains “stability stud*”Read the Form 483 →

  5. Cerovene Inc.Inspection ended Mar 23, 2026 · FEI 3005890568 · Observation 3

    … I observed the following expired stock and working standards used for the testing of commercial drug products, in this cabinet: Product Type of Preparation | Expiry Date | Expiry after according to Brgparation (b) (4) Tmpuity Ju 25, Method Validation Tablets (b) (4), — od MVR (6) (4) Related (b) (4) § Substances 2018 95 Stock standard | January 30, (®)@) for assay 2026 Method Validation Tablets (©) @) Working standard for assay January 30, 2018 …

    Contains “expiry dat*”Read the Form 483 →

  6. SGS North America Inc.Inspection ended Mar 20, 2026 · FEI 1418028 · Observation 1

    … not perform minimum verification testing to qualify the reference standards you use for testing of various drug products and raw materials for release, or for stability testing. Instead, according to SOP-000898, Reference Standards, Version 4, your firm relies on a review of the Certificate of Analysis of incoming lots to assess the quality of the reference standard. Examples are as follows: A. Your firm used (b) (4) Reference Standard (Lot (DB) …

    Contains “stability test*”Read the Form 483 →

  7. BioChem Sioux City, Inc.Inspection ended Mar 19, 2026 · FEI 1910218 · Observation 1

    The firm has not established an ongoing stability program for heparin sodium crude (b)(4) to support the assigned (b)(4) expiration date. For example, the firm provided only one stability report from 2018 (Ref.: SRS-STAB 2017-014, art. no. 44.538.300, authorized 14 Feb 2018), with no subsequent stability studies conducted through March 2026.

    Contains “ongoing stability”Read the Form 483 →

  8. BioChem Sioux City, Inc.Inspection ended Mar 19, 2026 · FEI 1910218 · Observation 2

    The firm follows procedure AMB-101355, BioChem WI: Heparin Sodium (b)(4) Assay, version 7.0, effective 16 Jul 2024, a modified method that has not been validated. For example, the firm has used this same modified method for approximately 15-20 years. Furthermore, the method is used release (b)(4) lots of heparin sodium crude from (b)(4) within expiration date.

    Contains “expiration dat*”Read the Form 483 →

  9. RayzeBio, IncInspection ended Feb 24, 2026 · FEI 3030530655 · Observation 1

    … Your firm lacked a procedure for recalls that details the steps to follow, within the shelf life of the products, in the case of batch failures due to analytical test failures or manufacturing deviations. C. Per SOP-00012 ("Corrective and Preventive Action (CAPA) Handling," v. 2, effective 04/14/2025), Quality Assurance (QA) is responsible for tracking CAPA quality events, and CAPA due dates can be extended during the Implementation phase with …

    Contains “shelf life”Read the Form 483 →

  10. Orean Personal Care LtdInspection ended Feb 20, 2026 · FEI 3010999645 · Observation 2

    … You did not initiate deviations for delayed stability studies. Specifically, you initiated Long Term stability studies for the process validation batches after >3 months from the date of manufacturing. Your Quality Head (b)(6) stated that the firm did not have a deviation procedure and shared a form, OTC Deviation Form FDAF012 Version 1 that the firm uses to record deviations. C. You did not follow your FDA Change Control Procedure, FDASOP001 …

    Contains “stability stud*”Read the Form 483 →

  11. Orean Personal Care LtdInspection ended Feb 20, 2026 · FEI 3010999645 · Observation 4

    … The finished product, (b)(4) mL Batch No's (b)(4) bulk batches manufactured from the (b)(4) failed at time t = 0 for the long-term (25 +/- 5 C/60 +/- 5% RH) stability study that is carried out at a third party. The (b)(4) also failed for (b)(4). In addition, Batch No. (b)(4) failed for pH (b)(4) against Specification (b)(4) [and] for viscosity (b)(4) cps against Specification (b)(4) cps. You have shipped a total of (b)(4) units from these …

    Contains “stability stud*”Read the Form 483 →

  12. Orean Personal Care LtdInspection ended Feb 20, 2026 · FEI 3010999645 · Observation 5

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. On 12/26/2025, your vendor (b)(4) who carries out stability study has recorded OOS result for (b)(4) mL. The OOS result was recorded for Batch No. (b)(4) (Mfg. date 7/7/2025 Expiry date (b)(4)) for pH (b)(4) against the …

    Contains “stability stud*”Read the Form 483 →

  13. Orean Personal Care LtdInspection ended Feb 20, 2026 · FEI 3010999645 · Observation 7

    There was a failure to handle and store components of drug product at all times in a manner to prevent contamination. Specifically, on 2/16/2026 during the walkthrough of your warehouse, I saw a bag of Lot No. (b)(4) Mfg. date May 2025 Expiry date (b)(4) of (b)(4). I saw the bag left open and was not sealed/secured. I also saw (b)(4) material in a (b)(4) bag on top of a carton of (b)(4) that belonged to one of the cartons with the Lot No. (b)(4). …

    Contains “expiry dat*”Read the Form 483 →

  14. Almon Healthcare Private LimitedInspection ended Feb 13, 2026 · FEI 3030509366 · Observation 2

    Your firm failed to use validated and stability-indicating test procedures. Your firm failed to use stability indicating methods to test active pharmaceutical ingredients (b)(4) batches shipped to the US market when assigning retest dates of (b)(4). The stability indicating aspects of in-house methods (b)(4) used for USP (b)(4) and the compendial method for (b)(4) were not evaluated through method validation and forced degradation studies to …

    Contains “stability indicating”Read the Form 483 →

  15. Almon Healthcare Private LimitedInspection ended Feb 13, 2026 · FEI 3030509366 · Observation 3

    … (b)(4) related substances by HPLC using outside laboratory's validated method failed to identify all the unknown related substances in the finished API and stability samples. Your firm is using this analytical method (STP [illegible]/005) for testing related substances in the finished API and stability samples.

    Contains “stability sample*”Read the Form 483 →

  16. Almon Healthcare Private LimitedInspection ended Feb 13, 2026 · FEI 3030509366 · Observation 11

    Failure to store stability samples in containers that simulate the market container. (b)(4) container bags used for stability samples to establish retest dates for APIs including (b)(4) for the US market. Your Executive QA confirmed that the firm uses (b)(4) bags used for bags as the (b)(4) container for API stability studies, which do not simulate the (b)(4) commercial packaging.

    Contains “stability sample*”Read the Form 483 →

  17. Biomylz Private LimitedInspection ended Feb 9, 2026 · FEI 3013697420 · Observation 1

    … market, all of which remain within their expiration dates. Moreover, on February 4, 2026, during the initial inspectional walkthrough of your facility, the following data integrity deficiencies were observed: A. Destroyed controlled records containing raw data were observed inside a trash bag located in the scrap room. The recovered documents included, but were not limited to, executed production batch records; media preparation, incubation, and …

    Contains “expiration dat*”Read the Form 483 →

  18. Biomylz Private LimitedInspection ended Feb 9, 2026 · FEI 3013697420 · Observation 2

    … Your firm has not established stability studies for (b)(4) OTC products distributed to the U.S. market. Specifically, firm management assigned a (b)(4) expiration date for (b)(4) OTC products. However, your firm lacks supporting stability data or other scientifically sound evidence to demonstrate that these products will meet established quality attributes throughout their shelf life.

    Contains “stability stud*”Read the Form 483 →

  19. SNJ Labs Private Ltd.Inspection ended Feb 6, 2026 · FEI 3026587575 · Observation 2

    Your firm failed to use validated and stability-indicating test procedures. Your firm failed to use validated, stability-indicating methods to test active pharmaceutical ingredients (API) (b) (4) (b) (4) intended for the US market when assigning retest dates of (b) (4) The analytical method used for testing stability samples is not stability indicating and cannot identify degradation products. Furthermore, your firm started stress studies for (b) …

    Contains “stability indicating”Read the Form 483 →

  20. Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 2

    There is no written testing program designed to assess the stability characteristics of drug products. Specifically, No stability studies have been conducted to support the (b) (4) expiration date applied for the OTC drug product (b) (4), USP ((b) (4) Tablet) in accordance with SOP-80 "Stability Studies". For example, (b) (4), USP ((b) (4) Tablet) Lot #(b) (4) and Lot #(b) (4), manufactured in (b) (4) and (b) (4), respectively, were assigned an …

    Opens with FDA's citation wording for 21 CFR 211.166(a)Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about stability in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.