Skip to content

SGS North America Inc.

616 Heathrow Dr, Lincolnshire, Illinois, United States

FEI 1418028DUNS 049859261

Company: SGS North America Inc. · Linked by exact D-U-N-S match (049859261) in FDA registration data

FDA has 10 inspections on file for SGS North America Inc. in Lincolnshire, Illinois (FEI 1418028), from 2009 to 2026. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below. One of the three FOIA requests for this site has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for analysis, through Dec 31, 2026. Its registrant, SGS North America Inc. (D-U-N-S 049859261), has registered 17 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
10, 2009–2026
0 OAI · 2 VAI · 8 NAI
Inspections with 483 observations shown
2 of 10
Form 483s posted by FDA
↗
Requested under FOIA
3 requests, latest May 8, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

10 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 observation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Insufficient reference standard verification

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Your firm does not perform minimum verification testing to qualify the reference standards you use for testing of various drug products and raw materials for release, or for stability testing. Instead, according to SOP-000898, Reference Standards, Version 4, your firm relies on a review of the Certificate of Analysis of incoming lots to assess the quality of the reference standard. Examples are as follows: A. Your firm used (b) (4) Reference Standard (Lot (DB) (4) supplied by (b) (4) received 04Jun2025) to conduct method transfer activities without performing verification testing to confirm the identity, quality, and suitability of the reference standard lot prior to use. According to your SOP SOP-000898 - Reference Standards, V4, section 5 your firm relies on the COA to verify the purity and identification of reference standards. Examples include, but are not limited to: o SGS-MT-09-25-29R, Method Transfer Report for the Determination of (B) (4) Concentration in (b) (4) by®® and Assay for (b) (4) in (b) (4) (b) (4) (November 03, 2025): Reference Standard Lot (b) (4) was used throughout the method transfer study (Section 4.2, page 7; Section 6.3.1.1, page 43) without documented evidence of verification testing upon receipt or prior to uses. o SGS-MT-09-25-20R, Method Transfer Report for Identification of (BD) (4) (b) (4) by (b) (4) (b) (4) (b) (4) (B)(4) (November 03, 2025): The same Reference Standard Lot (b) (4) was used as the positive control throughout all (®)(4) independent assay sessions (Section 6.3.3, pages 44-45; Table 6, page 47) without documented verification testing. B. According to SGS protocol SGS-$S-09-24-001, Release Testing for (BD) (4) (b) 4) for (b) (4) (January 08, 2026, through February 10, 2026): (b) (4) Reference Standard (Lot (b) (4)) was used throughout multiple analytical methods for release testing of Batch (b) (4) (Assignment (b) (4) /Sample (b) (4)) without documented evidence of verification testing upon receipt or prior to use. The reference standard was utilized in the following methods: [HPLC Assay (Method 09D05-563) [Dissolution Testing (Method 09D05-467) The Certificate of Analysis (pages 43-48, dated 09-Feb-2026, corrected version 3 dated 10-Mar-2026) reports results for (D) (4) Assay (98.6%), (0) (4) Impurities and Degradation Products, and Stage” Dissolution testing, all of which relied on the reference standard for quantitation and system suitability. C. According to Lab Assignment ID (b) (4) (SGS Protocol SGS-SS-09-22-04P, Release Testing for (b) (4)) for (b) (4) (December 04, 2025, through December 17, 2025) your firm used USP (b) (4) reference standard (RS) (Lot (b) (4)) to perform release testing for (b) (4) for (b) (4) (B)(4) dose lot (b) (4) (Assignment (b) (4) /Sample (b) (4)) Released on (D) (4). The Certificate of Analysis (pages 49-56, dated 19-Dec-2025) reports results for (BD) (4) Assay (102.9%), (0) (4) Impurities and Degradation Products, Uniformity of Content, and Stage” Dissolution testing. Tests using this sample and reference standard include: [Identification, Impurities, and Uniformity of Content (Method 09D05-428) [HPLC Assay (Method 09D05-564) [Dissolution Testing (Method 09D05-345) These tests were performed using a reference standard that had not undergone minimal verification testing to qualify the RS upon receipt and prior to use.

  2. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
  7. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  9. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  10. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on May 8, 2026.

  • Inspection ending Mar 20, 2026VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. May 8, 2026FDA-FOIA-2026-4747Form 483· 1 of 4 sitesRecords released
  • Inspection ending Jan 10, 2023VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Oct 17, 2024FDA-FOIA-2024-9190EIRClosed
  • Inspection ending Apr 24, 2019NAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Apr 14, 2021FDA-FOIA-2021-2474EIRClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 1 section of 21 CFR in FDA’s published citations for 1 of this facility’s 10 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

FDA drug establishment registration

FDA registration search
Registered operations
Analysis
Registration runs through
Dec 31, 2026
Registrant
SGS North America Inc.D-U-N-S 049859261

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names SGS North America Inc. (D-U-N-S 049859261) as the registrant for this site and 17 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 1418028 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 1418028. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.