SGS North America Inc. Form 483, March 2026
FDA issued this Form 483 to SGS North America Inc. in Lincolnshire, Illinois (FEI 1418028) at the end of a drug inspection that ran from March 17 to March 20, 2026. It lists 1 observation. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jul 9, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection
- Mar 17–20, 2026
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jul 9, 2026
- 111 days after the inspection
The 1 observation on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Insufficient reference standard verification
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Your firm does not perform minimum verification testing to qualify the reference standards you use for testing of various drug products and raw materials for release, or for stability testing. Instead, according to SOP-000898, Reference Standards, Version 4, your firm relies on a review of the Certificate of Analysis of incoming lots to assess the quality of the reference standard. Examples are as follows: A. Your firm used (b) (4) Reference Standard (Lot (DB) (4) supplied by (b) (4) received 04Jun2025) to conduct method transfer activities without performing verification testing to confirm the identity, quality, and suitability of the reference standard lot prior to use. According to your SOP SOP-000898 - Reference Standards, V4, section 5 your firm relies on the COA to verify the purity and identification of reference standards. Examples include, but are not limited to: o SGS-MT-09-25-29R, Method Transfer Report for the Determination of (B) (4) Concentration in (b) (4) by®® and Assay for (b) (4) in (b) (4) (b) (4) (November 03, 2025): Reference Standard Lot (b) (4) was used throughout the method transfer study (Section 4.2, page 7; Section 6.3.1.1, page 43) without documented evidence of verification testing upon receipt or prior to uses. o SGS-MT-09-25-20R, Method Transfer Report for Identification of (BD) (4) (b) (4) by (b) (4) (b) (4) (b) (4) (B)(4) (November 03, 2025): The same Reference Standard Lot (b) (4) was used as the positive control throughout all (®)(4) independent assay sessions (Section 6.3.3, pages 44-45; Table 6, page 47) without documented verification testing. B. According to SGS protocol SGS-$S-09-24-001, Release Testing for (BD) (4) (b) 4) for (b) (4) (January 08, 2026, through February 10, 2026): (b) (4) Reference Standard (Lot (b) (4)) was used throughout multiple analytical methods for release testing of Batch (b) (4) (Assignment (b) (4) /Sample (b) (4)) without documented evidence of verification testing upon receipt or prior to use. The reference standard was utilized in the following methods: [HPLC Assay (Method 09D05-563) [Dissolution Testing (Method 09D05-467) The Certificate of Analysis (pages 43-48, dated 09-Feb-2026, corrected version 3 dated 10-Mar-2026) reports results for (D) (4) Assay (98.6%), (0) (4) Impurities and Degradation Products, and Stage” Dissolution testing, all of which relied on the reference standard for quantitation and system suitability. C. According to Lab Assignment ID (b) (4) (SGS Protocol SGS-SS-09-22-04P, Release Testing for (b) (4)) for (b) (4) (December 04, 2025, through December 17, 2025) your firm used USP (b) (4) reference standard (RS) (Lot (b) (4)) to perform release testing for (b) (4) for (b) (4) (B)(4) dose lot (b) (4) (Assignment (b) (4) /Sample (b) (4)) Released on (D) (4). The Certificate of Analysis (pages 49-56, dated 19-Dec-2025) reports results for (BD) (4) Assay (102.9%), (0) (4) Impurities and Degradation Products, Uniformity of Content, and Stage” Dissolution testing. Tests using this sample and reference standard include: [Identification, Impurities, and Uniformity of Content (Method 09D05-428) [HPLC Assay (Method 09D05-564) [Dissolution Testing (Method 09D05-345) These tests were performed using a reference standard that had not undergone minimal verification testing to qualify the RS upon receipt and prior to use.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.