Bausch & Lomb Incorporated
8507 Pelham Rd, Greenville, South Carolina, United States
FEI 1032500DUNS 114406598
FDA has 10 inspections on file for Bausch & Lomb Incorporated in Greenville, South Carolina (FEI 1032500), from 2009 to 2025. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 3 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Eight FOIA requests have asked FDA for this inspection's 483.
1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant is Bausch & Lomb Incorporated (D-U-N-S 114406598).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 10, 2009–2025
- 1 OAI · 4 VAI · 5 NAI
- Inspections with 483 observations shown
- 6 of 10
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 8 requests, latest Sep 21, 2026
- Warning letters
- None on file
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
10 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Sampling/testing of drug products
The specifications for drug products are deficient in that they do not include a description of the sampling plan for drug products.
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Design verification - Lack of or inadequate procedures
Procedures for design verification have not been adequately established.
Lack of or inadequate process validation
A process whose results cannot be fully verified by subsequent inspection and test has not been adequately validated according to established procedures.
Lack of or inadequate procedures
Procedures for corrective and preventive action have not been adequately established.
Report of Death or Serious Injury
An MDR report was not submitted within 30 days of receiving or otherwise becoming aware of information that reasonably suggests that a marketed device may have caused or contributed to a death or serious injury.
Lack of or inadequate complaint procedures
Procedures for receiving, reviewing, and evaluating complaints by a formally designated unit have not been adequately established.
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Nonconforming product, Lack of or inadequate procedures
Procedures have not been adequately established to control product that does not conform to specified requirements.
Documentation
Process validation activities and results have not been adequately documented.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Environmental control Lack of or inadequate procedures
Procedures to control environmental conditions have not been adequately established.
Written program not followed
The written stability testing program is not followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Quality Audits - defined intervals
Quality audits were not performed at defined intervals to determine whether the quality system activities and results comply with quality system procedures.
Production processes
Production processes were not monitored to ensure that a device conforms to its specifications.
Equipment control activity documentation
Equipment checks have not been documented.
Incoming acceptance records, documentation
Acceptance or rejection of incoming product was not documented.
Documentation
Corrective and preventive action activities and/or results have not been adequately documented.
Show 7 more citations
Process control procedures, Lack of or inadequate procedures
Process control procedures that describe any process controls necessary to ensure conformance to specifications have not been adequately established.
Identification procedures, Lack of or inadequate procedures
Procedures for identifying product during all stages of receipt, production, distribution, and installation have not been adequately established.
Design plans - Lack of or inadequate
Design plans that describe or reference the design and development activities and define responsibility for implementation have not been adequately established.
Acceptance status
The acceptance status of product was not identified to indicate conformance or nonconformance with acceptance criteria.
Training records
Personnel training is not documented.
Environmental control Lack of or inadequate procedures
Procedures to control environmental conditions have not been adequately established.
Management review - defined interval, sufficient frequency
Management with executive responsibility has not reviewed the suitability and effectiveness of the quality system with sufficient frequency.
- NAINo objectionable conditions that need follow-upDevices · Postmarket Assurance: Devices10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Documentation of disposition, justification, signature
There is incomplete documentation of the disposition of nonconforming product and justification for use of nonconforming product.
Changes to correct/prevent quality problems
Changes in methods and procedures needed to correct and prevent identified quality problems are not recorded.
Environmental control Lack of or inadequate procedures
Appropriate procedures have not been followed for controlling environmental conditions.
Quality System Procedures
Quality system procedures were not established and implemented.
Identification of actions needed
Not all of the actions needed to correct and prevent the recurrence of nonconforming product and other quality problems have been identified.
Show 5 more citations
Design plans - Lack of or inadequate
The design plan does not describe the design and development activities, define responsibility for implementation of design and development activities, and identify and describe the interfaces with other groups or activities as appropriate.
Process control instructions
Process controls are not conducted in accordance with documented instructions and standard operating procedures.
Documentation
Corrective and preventive action activities have not been documented, including investigations of causes of nonconformities, the actions needed to correct or prevent recurrence of nonconforming product and other quality problems, and implementation of corrective and preventive actions.
CAPA verification/validation of corrective/preventive action
Corrective and preventive actions have not been verified or validated to ensure that the action is effective and does not adversely affect the finished device.
Records accessibility
Investigated complaints and records of investigation were not accessible to the manufacturing establishment.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Eight requests to FDA under the Freedom of Information Act named this site, most recently on Sep 21, 2026. Each one asked for a Form 483.
Inspection ending Feb 27, 2025OAI
8 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 8, 2025. FDAgent holds no copy that FDA posted.
- Sep 21, 2026FDA-FOIA-2026-9134Form 483Withdrawn
- Aug 20, 2026FDA-FOIA-2026-8097Form 483Records released
- Jul 13, 2026FDA-FOIA-2026-6655Form 483Records released
- Jun 2, 2026FDA-FOIA-2026-5468Form 483Records released
- May 18, 2026FDA-FOIA-2026-5061Form 483· 1 of 4 sitesWithdrawn
- Jul 11, 2025FDA-FOIA-2025-8586Form 483Records released
- Jun 20, 2025FDA-FOIA-2025-7865Form 483· 1 of 10 sitesRecords released
- May 22, 2025FDA-FOIA-2025-4543Form 483· 1 of 5 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 19 sections of 21 CFR in FDA’s published citations for 6 of this facility’s 10 inspections, with how many of them cited each.
- 21 CFR 820.30Design controls3 of 6
- 21 CFR 820.70Production and process controls3 of 6
- 21 CFR 820.100Corrective and preventive action3 of 6
- 21 CFR 211.160General requirements2 of 6
- 21 CFR 820.20Management responsibility2 of 6
- 21 CFR 820.75Process validation2 of 6
- 21 CFR 820.90Nonconforming product2 of 6
- 21 CFR 820.198Complaint files2 of 6
Show all 19
- 21 CFR 211.67Equipment cleaning and maintenance1 of 6
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 6
- 21 CFR 211.113Control of microbiological contamination1 of 6
- 21 CFR 211.166Stability testing1 of 6
- 21 CFR 803.50If I am a manufacturer, what reporting requirements apply to me?1 of 6
- 21 CFR 820.22Quality audit1 of 6
- 21 CFR 820.25Personnel1 of 6
- 21 CFR 820.60Identification1 of 6
- 21 CFR 820.72Inspection, measuring, and test equipment1 of 6
- 21 CFR 820.80Receiving, in-process, and finished device acceptance1 of 6
- 21 CFR 820.86Acceptance status1 of 6
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1032500, one row per refused product line.
1 refusal on 2023-01-03 · charged NOT LISTED on 1, FRNMFGREG on 1 · no FDA sample analysis
FDA firm profile- 2023-01-03
PRODUCTS, CONTACT LENS CARE, RIGID GAS PERMEABLE86MRC
NOT LISTED 502(o), 801(a)(3); MISBRANDING
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
REGISTERED 502(o), 801(a)(3); MISBRANDING
NO 510(K) 801(a)(3); 502(o) Misbranding
Division of Southeast Imports799-2183687-0/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Bausch & Lomb IncorporatedD-U-N-S 114406598
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other FEIs recorded as Bausch & Lomb Incorporated
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Bausch & Lomb IncorporatedFEI 1317628Rochester, New York, United States
Last inspected 2025-07-30NAI
Bausch & Lomb IncorporatedFEI 1000113778Tampa, Florida, United States
Last inspected 2023-08-25NAI
Bausch & Lomb IncorporatedFEI 3003434767Irvine, California, United States
Last inspected 2020-02-28VAI
Bausch & Lomb IncorporatedFEI 1315522Lancaster, New York, United States
Last inspected 2017-02-15VAI
Bausch & Lomb IncorporatedFEI 1281950Wilmington, Massachusetts, United States
Last inspected 2013-07-31VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1032500 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1032500. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.