Skip to content

Compounding pharmacies and outsourcing facilities in FDA Form 483 observations

Observations at pharmacies and 503B outsourcing facilities that compound drugs: beyond-use dates, patient-specific prescriptions and compounding practices. FDAgent finds 268 such observations in 114 Form 483s issued to 105 facilities, for inspections that ended between November 2012 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
268
Each quoted below
Form 483s
114
Posted by FDA
Facilities
105
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 71 in 2026

Compounding observations in Form 483s by inspection year
YearObservations
20121
20132
20146
20157
201610
201715
201827
201934
20208
202130
202221
202313
20249
202514
202671

How FDAgent sorts observations into this theme

One fixed rule, applied by code to every observation FDAgent can quote. No model and no similarity score decides.

Its text contains one of these phrases

“compounded” · “compounding” · “compounder*” · “503A” · “503B” · “outsourcing facilit*” · “pharmacist*” · “pharmacy” · “pharmacies” · “beyond use dat*” · “BUD*” · “USP 797” · “patient specific” · “prescription*”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 268 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 1

    The (b)(4) intended to render final product sterile is not adequate to accomplish sterilization and/or is not pharmaceutical grade. Specifically, a. Your firm uses the (b)(4) when compounding large volume batches of sterile finished product. The (b)(4) does not appear to be pharmaceutical grade and the labeling for the (b)(4) states "Do not use these systems in direct patient care applications." There is no (b)(4) testing method for the (b)(4). …

    Contains “compounding”Read the Form 483 →

  2. One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 2

    The cycle parameters (b)(4) used for (b)(4) of product intended to be sterile are not verified to be lethal to (b)(4) microorganisms. Specifically, a. Your firm performs all compounding and filling operations for (b)(4) pellet products in an unclassified Biosafety Cabinet, located in an unclassified room. Pellet products include: Estradiol, 10 mg, 12.5 mg, 15 mg, 20 mg, 25 mg, 35 mg, 40 mg, 50 mg, 55 mg Pellets; Naltrexone, 200 mg Pellets; …

    Contains “compounding”Read the Form 483 →

  3. One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 5

    … Pharmacy Lab Manager and Technicians confirmed that after spraying (b)(4) on the surface, the solution is immediately removed. Demonstration of the effectiveness of the cleaning operations was not assessed due to lack of established contact times.

    Contains “pharmacy”Read the Form 483 →

  4. One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 7

    … There is no assurance that these conditions [illegible] sterilization or depyrogenation these materials prior to use in compounding sterile drug products.

    Contains “compounding”Read the Form 483 →

  5. One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 9

    … During filling operations, we observed that the doors from the ISO 8 compounding room to the ISO 7 Ante room; and the door from the ISO ? Ante-Room to the ISO 7 aseptic filling room, did not stay consistently closed. We heard multiple alarms during the aseptic filling due to loss in pressure. The firm cannot assure continuous positive pressure during filling operations.

    Contains “compounding”Read the Form 483 →

  6. Option Care Enterprises Inc. dba Option CareInspection ended Feb 8, 2018 · FEI 3012188090 · Observation 3

    3. Your facility design allows the influx of poor quality air into a higher classified area. Specifically, I observed that the uncontrolled refrigerated pass through that separates the ISO 7 buffer room from the uncontrolled pharmacy processing area has a refrigeration fan blowing unfiltered chilled air into this space. The refrigerated space is used to pass finished sterile drug product from the ISO 7 buffer room into the uncontrolled pharmacy …

    Contains “pharmacy”Read the Form 483 →

  7. Option Care Enterprises Inc. dba Option CareInspection ended Feb 8, 2018 · FEI 3012188090 · Observation 4

    4. Media fills were not performed under the most challenging or stressful conditions. Specifically, your procedures for media fills do not fully emulate the number and type of connections used to produce all parenteral nutrition drug products using the ) (~) b) (4). Option Care utilizes an b 4 b) (4) to produce Total Parenteral Nutrition drug products such as Rx b) (6) compounded on 12/28/2017. The o 4 requires the ~) b) (4) during initial set-up …

    Contains “compounded”Read the Form 483 →

  8. Accurate Rx Pharmacy Consulting, LLC dba Accurate Rx PharmacyInspection ended Aug 14, 2017 · FEI 3013446837 · Observation 1

    Observation 1: Your ISO5 classified workstation where sterile product are prepared is located within a non-classified room. Specifically, A. Your (15)(4) "compounding aseptic (15)(4)" is not located in a controlled environment/room in order to prevent the risk of contamination. On 7/31/2017, during the production of saline water bags, the (15)(4) was observed to be equipped with (15)(4) and is therefore not completely enclosed to the environment. …

    Contains “compounding”Read the Form 483 →

  9. D&S Enterprises, LLC dba Miller’s Health Mart PharmacyInspection ended Aug 9, 2017 · FEI 3013675130 · Observation 1

    Observation 1 Your Pharmacy is producing sterile drugs in Compound buffer room. In addition, injectable sterile products ing Aseptic Isolator (CAI) that is located in an unclassified are assigned a BUD of greater than 12 hours. For example, your pharmacy produced approximately a total of combined Morphine and Hydrocodone prescriptions for the year 2016 that were assigned a BUD of 48 hours at room temperature and 14 days in the refrigerator.

    Contains “pharmacy”Read the Form 483 →

  10. I.V. Specialty Ltd.Inspection ended Jul 28, 2017 · FEI 3010836489 · Observation 2

    … Your pharmacist stated this room is intended to meet ISO 7 and ISO 8 environment standards respectively. G. The door to the ISO 7 clean room is constructed of a wood laminate approximately 15 feet away from the ISO 5 LAF Hood used for processing sterile drugs. This wood laminate creates a difficult to sanitize surface in the clean room. H. The ceiling of the ISO 7 clean room has a tear in the plastic surface of the drop-ceiling tile approximately …

    Contains “pharmacist*”Read the Form 483 →

  11. I.V. Specialty Ltd.Inspection ended Jul 28, 2017 · FEI 3010836489 · Observation 3

    OBSERVATION 3 Aseptic practices in critical area are not adequate for sterile drug processing. On 25 July 2017, we observed: A. The pharmacist touching item on floor and return to processing TPN products without changing gloves. B. The pharmacist using a barcode scanner from outside hood and return to processing without sanitizing gloves.

    Contains “pharmacist*”Read the Form 483 →

  12. I.V. Specialty Ltd.Inspection ended Jul 28, 2017 · FEI 3010836489 · Observation 4

    OBSERVATION 4 Cleaning or Sanitizing of ISO 7 clean room is not adequate. On 25 July 2017, we observed: A. Pharmacist did not use a top-down approach to daily cleaning, the floor was cleaned first, then preparation tables. The bottom shelf of the preparation table was not sanitized where the (b)(4) pump is stored and the legs of the (b)(4) pump were not sanitized. B. The container labeled "Sterile Water" in the clean room is not sterile. …

    Contains “pharmacist*”Read the Form 483 →

  13. Vital Rx, Inc. dba Atlantic Pharmacy and CompoundingInspection ended Jul 20, 2017 · FEI 3011775721 · Observation 2

    … We observed this filter falling onto the working surface of this hood prior to use by the pharmacy technician. We also observed that it was held in place using packing tape which was difficult to clean. 5.) The laminar flow hood (ISO 5) (o)(4) air vent through which first air passes had a visible stain. Additional examples of sterile drug products for weekly IV infusion therapy over 4 weeks prepared under these conditions include: 1.) Ascorbic …

    Contains “pharmacy”Read the Form 483 →

  14. Vital Rx, Inc. dba Atlantic Pharmacy and CompoundingInspection ended Jul 20, 2017 · FEI 3011775721 · Observation 3

    Your form failed to perform adequate media fill studies in that they did not closely simulate aseptic operations incorporating as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, the most recent media fill documentation which demonstrates the ability of your pharmacy technician to prepare sterile drug preparations was performed on 12/20/16 and 1111117 did not include the following: …

    Contains “pharmacy”Read the Form 483 →

  15. ARJ Infusion Services, Inc.Inspection ended May 25, 2017 · FEI 3013452490 · Observation 1

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. You have not performed your media fill during worst case processing conditions of your sterile processed drugs. B. Your main pharmacy technician has not performed a media fill at your current address. C. You have not performed dynamic smoke studies in your laminar air flow hood. D. Air pressures are not monitored during sterile …

    Contains “pharmacy”Read the Form 483 →

  16. ARJ Infusion Services, Inc.Inspection ended May 25, 2017 · FEI 3013452490 · Observation 3

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, I observed sterile processing of Normal Saline/Sodium Chloride 0.9% (identified by raw material lot (b) (4) and (b) (4)) conducted by your Pharmacy Technician in your laminar air flow hood on 5/16/2017 and 5/17/2017. During sterile processing, I observed the following inadequate aseptic …

    Contains “pharmacy”Read the Form 483 →

  17. Pharmacy Associates, Inc.Inspection ended May 24, 2017 · FEI 3009145318 · Observation 7

    Observation #7: Environmental monitoring was not performed in your aseptic processing areas. a.) Personnel Monitoring is not being performed by your firm. Per your firm management, your firm does not have the (b) (4) to perform this testing. Furthermore, the firm does not monitor compounding personnel (i.e. gloved fingers).

    Contains “compounding”Read the Form 483 →

  18. Meditech Laboratories, Inc.Inspection ended May 11, 2017 · FEI 3012200488 · Observation 1

    Drugs were produced without providing adequate containment and cleaning of utensils to prevent cross-contamination. Specifically, On 05/09/2017, a plastic scoop used to scoop out bulk drug substances for production was observed in the drawer in the production area containing visible white powder residue. Your firm's pharmacist in charge was unable to identify what the substances are and unable to determine when it was last cleaned. Your pharmacy …

    Contains “pharmacist*”Read the Form 483 →

  19. MedPark Pharmacy LLCInspection ended Mar 10, 2017 · FEI 3012299349 · Observation 2

    OBSERVATION 2 The system for maintaining environmental conditions in Specifically, sterile drug preparation is conducted by an (b)(4) which is also (b)(4) unclassified room that opens to the general pharmacy area. Furthermore, there are (b)(4) and are open to the air. In addition, a pair of sterile gloves are placed to perform (b)(4) to prepare sterile drug products. These approximately (b)(4) in order to unclassified room. This is a repeat …

    Contains “pharmacy”Read the Form 483 →

  20. MedPark Pharmacy LLCInspection ended Mar 10, 2017 · FEI 3012299349 · Observation 4

    OBSERVATION 4 The aseptic technique used to prevent microbiological contamination deficient. Specifically, on 01/24/2017 during the preparation of 0.01% atropine eye drops pursuant to (b)(6) (BUD 02/23/17 - 30 days), the operator who prepared the drug passed the finished product container that was holding the of first air to the container. Furthermore, the (b)(4) sodium chloride (b)(4)

    Contains “BUD*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about compounding in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.