Skip to content

Meditech Laboratories, Inc

3200 Polaris Ave Ste 27, Las Vegas, Nevada, United States

FEI 3012200488

FDA has 2 inspections on file for Meditech Laboratories, Inc in Las Vegas, Nevada (FEI 3012200488), from 2016 to 2017. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Jul 21, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below.

The most recent OAI inspection ended on Mar 18, 2016. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2016–2017
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate cleaning to prevent cross-contamination

      Drugs were produced without providing adequate containment and cleaning of utensils to prevent cross-contamination. Specifically, On 05/09/2017, a plastic scoop used to scoop out bulk drug substances for production was observed in the drawer in the production area containing visible white powder residue. Your firm's pharmacist in charge was unable to identify what the substances are and unable to determine when it was last cleaned. Your pharmacy technician confirmed this was the only scoop used for compounding in the entire facility. The most recent products were produced 4 days prior on 05/05/17 and include: - Imperex Plus Lot 050517-IP produced on 05/05/17 - Imperex Lot 050517-1 produced on 05/05/17 - Imperex Plus Lot 050117-IP produced on 05/01/17 The firm has also produced, the following products this year in 2017: - GCB-Gabapentin 10%, Cyclobenzaprine 6%, Bupivacaine 5% Cream - FBD-Flurbip. 20%, Baclofen 5%, DMS 2%, Camphor 2%, Cap 0.025% Cream - KBC - Ketoprofen 20% / Baclofen 2% / Cyclobenzaprine 2% Cream

  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    2. Air Supply

      Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

    3. Protective Apparel Not Worn

      Protective apparel is not worn as necessary to protect drug products from contamination.

    4. Protection from external factors

      Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.

    5. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    Show 8 more citations
    1. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

    2. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    3. Written distribution procedure

      Written distribution procedures are not followed.

    4. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

    5. Containers & Closures Clean, Sterilized, Pyrogen-free

      Drug product containers and closures were not clean and sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.

    6. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

    7. Quality control unit review of records

      Drug product production and control records, are not approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.

    8. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

Regulations FDA cited here

The 9 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.

Show all 9

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3012200488 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3012200488. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.