Medical Chemical Corporation
19250 Van Ness Ave, Torrance, California, United States
FEI 2013736DUNS 008496861
FDA has 7 inspections on file for Medical Chemical Corporation in Torrance, California (FEI 2013736), from 2010 to 2025. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 8 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Six FOIA requests have asked FDA for this inspection's 483.
No court action or import refusal is filed under this FEI.
Nine regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, relabeling and repacking, through Dec 31, 2026. Its registrant is Medical Chemical Corporation (D-U-N-S 008496861).
Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 7, 2010–2025
- 1 OAI · 5 VAI · 1 NAI
- Inspections with 483 observations shown
- 6 of 7
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 6 requests, latest May 18, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Component written specification
Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
Test methods
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established.
Extent of discrepancy, failure investigations
Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other drug products that may have been associated with the specific failure or discrepancy.
Establish reliability of supplier's C of A
Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
Complete Test Data
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
Show 3 more citations
Absence of Written Procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing.
Component identity verification
Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Postmarket Assurance: Devices2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Complaints
Complaint files are not adequately maintained.
Lack of or inadequate process validation
A process whose results cannot be fully verified by subsequent inspection and test has not been validated according to established procedures.
- NAINo objectionable conditions that need follow-upDevices · Postmarket Assurance: Devices5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Evaluation of suppliers, contractors, etc., requirements
Requirements that must be met by suppliers have not been adequately established.
Design changes - Lack of or Inadequate Procedures
Procedures for design change have not been adequately established.
Lack of or inadequate complaint procedures
Procedures for receiving, reviewing, and evaluating complaints by a formally designated unit have not been adequately established.
Lack of or inadequate process validation
A process whose results cannot be fully verified by subsequent inspection and test has not been validated according to established procedures.
Training - Lack of or inadequate procedures
Procedures for training and identifying training needs have not been adequately established.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
Authority lacking to review records, investigate errors
The quality control unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred.
Written program not followed
The written stability testing program is not followed.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training required to perform their assigned functions.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Show 2 more citations
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the storage of components, drug product containers and closures.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Adequate space lacking to prevent mix-ups and contamination
The building lacks adequate space for the orderly placement of equipment and materials to prevent mix-ups between drug product containers, labeling, in-process materials, and drug products and to prevent contamination.
Data secured in course of each test
Laboratory records do not include a complete record of all data secured in the course of each test, including all graphs, charts, and spectra from laboratory instrumentation, properly identified to show the specific component, in-process material, and drug product tested.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Show 1 more citation
GMP Training Frequency
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: DevicesCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Lack of Written MDR Procedures
Written MDR procedures have not been developed.
Supplier notification of changes
There is no agreement with suppliers to notify you of changes in the product or service.
Production processes
Production processes were not conducted, controlled, and monitored to ensure that a device conforms to its specifications.
Training records
Personnel training is not documented.
Show 7 more citations
Documentation
Acceptance activities were not adequately maintained as part of the device history record.
Calibration - at intervals, written program, remedial action
The calibration of instruments, apparatus, gauges, and recording devices is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
Quality audits - auditor independence
Individuals who conduct quality audits have direct responsibility for the matters being audited.
Quality Audit/Reaudit - conducted
Quality audits have not been performed.
Packaging line inspection documentation
Results of inspection of packaging and labeling facilities are not documented in the batch production records.
Calibration/Inspection/Checking not done
Routine inspection of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not reviewed and approved by the quality control unit.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Six requests to FDA under the Freedom of Information Act named this site, most recently on May 18, 2026. Each one asked for a Form 483.
Inspection ending Feb 18, 2025OAI
6 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 8, 2025. FDAgent holds no copy that FDA posted.
- May 18, 2026FDA-FOIA-2026-5055Form 483· 1 of 5 sitesWithdrawn
- Mar 3, 2026FDA-FOIA-2026-2142Form 483Records released
- Sep 29, 2025FDA-FOIA-2025-11394Form 483· 1 of 4 sitesRecords released
- Jul 11, 2025FDA-FOIA-2025-8590Form 483Records released
- Jun 20, 2025FDA-FOIA-2025-7863Form 483· 1 of 10 sitesRecords released
- Apr 16, 2025FDA-FOIA-2025-3464Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 25 sections of 21 CFR in FDA’s published citations for 6 of this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 211.25Personnel qualifications2 of 6
- 21 CFR 211.67Equipment cleaning and maintenance2 of 6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 6
- 21 CFR 211.100Written procedures; deviations2 of 6
- 21 CFR 211.125Labeling issuance2 of 6
- 21 CFR 211.160General requirements2 of 6
- 21 CFR 211.194Laboratory records2 of 6
- 21 CFR 820.25Personnel2 of 6
Show all 25
- 21 CFR 820.50Purchasing controls2 of 6
- 21 CFR 820.75Process validation2 of 6
- 21 CFR 820.198Complaint files2 of 6
- 21 CFR 211.22Responsibilities of quality control unit1 of 6
- 21 CFR 211.42Design and construction features1 of 6
- 21 CFR 211.80General requirements1 of 6
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 6
- 21 CFR 211.130Packaging and labeling operations1 of 6
- 21 CFR 211.165Testing and release for distribution1 of 6
- 21 CFR 211.166Stability testing1 of 6
- 21 CFR 211.188Batch production and control records1 of 6
- 21 CFR 211.192Production record review1 of 6
- 21 CFR 803.17What are the requirements for developing, maintaining, and implementing written MDR procedures that apply to me?1 of 6
- 21 CFR 820.22Quality audit1 of 6
- 21 CFR 820.30Design controls1 of 6
- 21 CFR 820.70Production and process controls1 of 6
- 21 CFR 820.80Receiving, in-process, and finished device acceptance1 of 6
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, relabeling, repacking
- Registration runs through
- Dec 31, 2026
- Registrant
- Medical Chemical CorporationD-U-N-S 008496861
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 2013736 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 2013736. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.