Blood and plasma establishments in FDA Form 483 observations
Blood banks and plasma centers: donor eligibility and deferral, collection, testing, labeling and records under 21 CFR Parts 606, 630 and 640. FDAgent finds 32 such observations in 21 Form 483s issued to 21 facilities, for inspections that ended between November 2008 and August 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 32
- Each quoted below
- Form 483s
- 21
- Posted by FDA
- Facilities
- 21
- Distinct FEIs
- Most recent
- Aug 18, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 14 in 2026
| Year | Observations |
|---|---|
| 2008 | 1 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 1 |
| 2013 | 0 |
| 2014 | 0 |
| 2015 | 2 |
| 2016 | 0 |
| 2017 | 0 |
| 2018 | 2 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 2 |
| 2023 | 0 |
| 2024 | 1 |
| 2025 | 9 |
| 2026 | 14 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR Part 60621 CFR Part 63021 CFR Part 640
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“blood” · “plasma” · “transfusion*” · “apheresis” · “donor deferral*”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 32 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 5
… One hood is designated for nuclear blood tagging, and the other is used for the production of testosterone cypionate injectable product intended to be sterile. No smoke study has been conducted to demonstrate that the airflow from one hood does not interfere with the airflow of the other. The smoke study videos also did not include the most dynamic conditions of use such as (b)(4).
Contains “blood”Read the Form 483 →
Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 7
Hazardous drugs and Highly potent drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. A. Specifically, testosterone compounding (a highly potent hormone), chemotherapy reconstitution (hazardous drugs), and blood radiolabeling (biohazardous material) are all performed within the same cleanroom (b)(4) using (b)(4) hoods in close …
Contains “blood”Read the Form 483 →
An individual (name left out)Inspection ended Apr 27, 2026 · FEI 3011908561 · Observation 1
… 1 Subject was taking exclusionary medication at screening 5/12/25 5/27/25 Inclusion 7, Exclusion 14 Subject did not meet any option for inclusion 7, systolic blood pressure was (b)(4) Hg at Visit 2 2/12/26 3/4/26 B. (b)(4) laboratory values for subjects in the (b)(4) study were available to blinded staff. (b)(4) laboratory values for Subject (b)(6), (b)(7)(C) were documented in the Month 27, 12/4/24 visit notes. At this visit, the subject was …
Contains “blood”Read the Form 483 →
New Infertility Center of St LouisInspection ended Apr 22, 2026 · FEI 3030378634 · Observation 3
… France is not included when asking about receiving any transfusion of blood or blood components between 1980 and the present for CJD or vCJD infection. b. Chlamydia is not included when assessing donors who have been treated for or had Chlamydia trachomatis infection in the preceding 12 months. 4. Under "Donor Testing" of anonymous and directed donors, the firm does not include Nucleic Acid Testing (NAT) of West Nile Virus (WNV) of HCT/Ps …
Contains “transfusion*”Read the Form 483 →
Novo NordiskInspection ended Apr 17, 2026 · FEI 3003037054 · Observation 1
Not all method validation activities were documented in source records from study. For instance, stability of (b)(4) in whole blood was evaluated after 1-hour, 2-hour, and 4-hour incubation periods at room temperature. However, source records have no time stamps to support the incubation time points. A similar finding was observed in the shipping and short-term stability experiments.
Contains “blood”Read the Form 483 →
Cliantha Research LimitedInspection ended Apr 17, 2026 · FEI 3017682080 · Observation 6
6. Legally effective informed consent was not obtained from a subject or the subject's legally authorized representative. Specifically, your general screening informed consent does not include a description of the specific procedures to be followed. You conducted mammograms, transvaginal ultrasounds, pap smears, and estradiol plasma concentrations on 48 enrolled subjects (plus extra subjects) prior to their study specific consent.
Contains “plasma”Read the Form 483 →
Biomat USA IncInspection ended Apr 14, 2026 · FEI 3014028128 · Observation 1
Failure to present educational material to the donor in an appropriate form and in a manner designed to be understood by the donor. (b) (6), (b) (7)(C) donor [illegible]. The donor's profile in the blood establishment system notifies your (b) (6), (b) (7)(C) employee that the donor must be [illegible]. Your employee failed to (b) (6), (b) (7)(C) to the donor since education materials relating to risk factors associated with relevant …
Opens with FDA's citation wording for 21 CFR 630.10(b)Read the Form 483 →
Biomat USA IncInspection ended Apr 14, 2026 · FEI 3014028128 · Observation 2
Failure to perform a thorough investigation and make a record of the conclusions and follow-up of an unexplained discrepancy. Specifically, your firm opened a deviation 2196858 on 11/19/22 which identified a donor with multiple accounts under (b) (6), (b) (7)(C). This issue was discussed during the previous inspection. This incident was reported to the FDA (BPD 851423) and products were identified as effected. The donor's profiles were merged on …
Opens with FDA's citation wording for 21 CFR 606.100(c)Read the Form 483 →
Biomat USA IncInspection ended Apr 14, 2026 · FEI 3014028128 · Observation 3
Failure to maintain donor, processing and general records. Specifically, you failed to maintain accurate records during the eligibility process and when treating donor adverse events. 1. When documenting adverse events, your employees fail to document treatment given to donors. On 4/9/26, your donor center specialist performed a venipuncture where blood spilled and (b) (4), (b) (6), (b) (7)(C) (b) (6), (b) (7)(C). Your firm classified this as a …
Opens with FDA's citation wording for 21 CFR 606.160(b)Read the Form 483 →
Biomat USA IncInspection ended Apr 14, 2026 · FEI 3014028128 · Observation 4
Written standard operating procedures including all steps to be followed in the collection and storage of blood and blood components for [illegible] were not always followed. Specifically, the following are examples where your employees did not follow standard operating procedures (SOPs). 1. Your employees filled the capillary tubes, used to determine hematocrit and total protein, (b) (4) (b) (4). The SOP "Donor Requirement - Hematocrit" states, …
Contains “blood”Read the Form 483 →
Scott & White Memorial HospitalInspection ended Apr 13, 2026 · FEI 1671265 · Observation 1
Written standard operating procedures including all steps to be followed in the distribution of blood and blood components for allogeneic transfusion were not always established and maintained. Specifically, your procedure (b)(4) Blood Bank Response to Activation, document number (b)(4)LAB-(b)(4)1019.R_V7, Origination Date 01/2018, does not adequately address what necessary information is required to be recorded on the Emergency Release of Blood …
Opens with FDA's citation wording for 21 CFR 606.100(b)Read the Form 483 →
Guam Memorial Hosp AuthorityInspection ended Mar 6, 2026 · FEI 1000523688 · Observation 1
Failure to obtain from the donor on the day of donation a postal address where the donor may be contacted for 8 weeks after donation. Specifically, your firm has failed to obtain confirmation from donors on the day of donation regarding whether they will be at their current address for 8 weeks following donation. Neither your printed donor educational materials nor your Medical Questionnaire review process addresses verification of a postal …
Opens with FDA's citation wording for 21 CFR 630.10(g)(1)Read the Form 483 →
Guam Memorial Hosp AuthorityInspection ended Mar 6, 2026 · FEI 1000523688 · Observation 2
Failure to make reasonable attempts to notify a donor who has been deferred based on the results of tests for evidence of infection with a relevant transfusion-transmitted infection(s). Specifically, donor was tested positive for hepatitis B core Antibody on (b) (6), (b) (7)(C) and you failed to send a letter of notification within 8 weeks to inform donor with abnormal results. According to your Standard Operative Procedure for Donor Notification …
Opens with FDA's citation wording for 21 CFR 630.40(a)Read the Form 483 →
Guam Memorial Hosp AuthorityInspection ended Mar 6, 2026 · FEI 1000523688 · Observation 3
Written standard operating procedures including all steps to be followed in the collection and distribution of blood and blood components for allogeneic transfusion were not always followed. Specifically, donor tested positive for hepatitis B core antibody on (b) (6), (b) (7)(C), and you failed to follow Standard Operating Procedure for Donor Notification of Abnormal Results, D117.01, effective January 5, 2000, which requires: 1) The Donor …
Opens with FDA's citation wording for 21 CFR 606.100(b)Read the Form 483 →
Inotiv Inc.Inspection ended Oct 24, 2025 · FEI 1000140135 · Observation 1
1. During the validation of insulin aspart in human serum (validation report #1000-2403020), the effect of lipemia for selectivity and matrix effect experiments was not evaluated. Specifically, the firm used plasma matrix to study the lipemia effect for selectivity and matrix effect in serum.
Contains “plasma”Read the Form 483 →
Inotiv Inc.Inspection ended Oct 24, 2025 · FEI 1000140135 · Observation 2
2. Whole blood stability of insulin aspart was not assessed during method validation (validation report #1000-2403020). Specifically, short term stability testing was conducted in plasma.
Contains “blood”Read the Form 483 →
Inotiv Inc.Inspection ended Oct 24, 2025 · FEI 1000140135 · Observation 3
3. Source records for method validation experiments of long-term stability (validation report #1000-091480-2), dilution integrity, stability in matrix and ion suppression (validation report #1000-091480-1), do not document that lithium heparinized human lysed whole blood was utilized as the matrix. The study samples from study utilized lithium heparinized human lysed whole blood.
Contains “blood”Read the Form 483 →
Creative Testing SolutionsInspection ended Aug 29, 2025 · FEI 3000204058 · Observation 2
Failure to perform a thorough investigation and make a record of the conclusions and follow-up of an unexplained discrepancy. Specifically, A. None of your firm’s standard operating procedures require investigation into all unexplained discrepancies. Your SOP titled, Error Management, only requires investigation into customer complaints and errors involving released test results. B. Your firm failed to thoroughly investigate and document improper …
Opens with FDA's citation wording for 21 CFR 606.100(c)Read the Form 483 →
Raptim Research Private LimitedInspection ended Jul 25, 2025 · FEI 3007267856 · Observation 1
… eSOP/ANA/001 states that biological matrix (e.g., plasma) should be used within one year after collection. The firm had multiple lots of pooled plasma samples exceeding the one-year expiration date that were not discarded. Examples include plasma lots: i. 210324 (b) (4) - stored on 21/Mar/2024; 46 mL not discarded ii. 210324 - stored on 21/Mar/2024; 135 mL not discarded iii. 180324 - stored on 18/Mar/2024; 144 mL not discarded iv. 080523 - stored …
Contains “plasma”Read the Form 483 →
Raptim Research Private LimitedInspection ended Jul 25, 2025 · FEI 3007267856 · Observation 2
The firm did not have adequate information in their source documents for complete reconstruction of study activities. a. Analytical staff could not locate the current storage location of lot 012024004103 of plasma. The plasma was transferred from the clinical department to the analytical department on 8/Nov/2024 for use as blank biological matrix for method development/validation. The Biological Matrix Consumption Record documented that the …
Contains “plasma”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 606.100Standard operating proceduresIn this theme's rule4
- 21 CFR 606.160RecordsIn this theme's rule2
- 21 CFR 630.10General donor eligibility requirementsIn this theme's rule2
- 21 CFR 312.60General responsibilities of investigators1
- 21 CFR 630.40Requirements for notifying deferred donorsIn this theme's rule1
- 21 CFR 803.30If I am a user facility, what reporting requirements apply to me?1
- 21 CFR 1271.47What procedures must I establish and maintain?1
- 21 CFR 1271.50How do I determine whether a donor is eligible?1
- 21 CFR 1271.75How do I screen a donor?1
- 21 CFR 1271.80What are the general requirements for donor testing?1
Ask FDAgent about blood and plasma in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.