Skip to content

Novo Nordisk Form 483, April 2026

FDA issued this Form 483 to Novo Nordisk in Malov, Denmark (FEI 3003037054) at the end of a drug inspection that ended April 17, 2026. It lists 2 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 6, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Apr 17, 2026
Drugs · Bioresearch Monitoring
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Nov 6, 2026
203 days after the inspection
Facility
FEI 3003037054
Malov, Denmark

The 2 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Missing timestamps for stability incubation times

    Not all method validation activities were documented in source records from study. For instance, stability of (b)(4) in whole blood was evaluated after 1-hour, 2-hour, and 4-hour incubation periods at room temperature. However, source records have no time stamps to support the incubation time points. A similar finding was observed in the shipping and short-term stability experiments.

  2. 2

    SOPs not followed for validation runs

    Existing standard operating procedures (SOPs) were not always followed during the conduct of method validation experiments. For instance, 2a. SOP Q053698, Section 9.8.2, states that only failed stability QCs should be included in subsequent confirmatory runs. Yet, confirmatory run 8 included a new full set of stability QCs instead of including only failing stability QCs from run 7. 2b. SOP Q053698, Section 5.1, states that an average percent relative error (%RE) should be calculated for each concentration (QC) level and used to accept or reject precision and accuracy (P&A) runs. Additionally, a P&A run should be rejected if the average %RE value exceeds 25% at LLOQ and ULOQ levels and 20% at all other QC levels. Yet, P&A run 9 was rejected based on visual assessment instead of a calculated average %RE value. At my request, average %RE values were calculated during the [illegible] incorrectly rejected because the average %RE value was [illegible] at all QC levels.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.