K.C. Pharmaceuticals, Inc.
3201 Producer Way, Pomona, California, United States
FEI 2026940DUNS 174450460
FDA has 11 inspections on file for K.C. Pharmaceuticals, Inc. in Pomona, California (FEI 2026940), from 2009 to 2026. The latest ended on and was classified OAI, official action indicated. FDA has issued 3 warning letters under this FEI, the latest on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 13 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three of the nine FOIA requests for this site have asked FDA for this inspection's 483.
No court action or import refusal is filed under this FEI.
18 regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for packing and labeling, through Dec 31, 2027. Its registrant is KC Pharmaceuticals, Inc. (D-U-N-S 174450460).
Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 11, 2009–2026
- 3 OAI · 6 VAI · 2 NAI
- Inspections with 483 observations shown
- 11 of 11
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 9 requests, latest May 19, 2026
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
11 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that components and in-process materials conform to appropriate standards of identity, strength, quality and purity.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
input/output verification
Input to and output from the computer, related systems of formulas and records or data are not checked for accuracy.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Show 8 more citations
Objectionable microbiological contamination
Each lot of a component, drug product containers and closures liable to objectionable microbiological contamination is deficiently subjected to microbiological tests before use.
Valid stability test methods
The written stability program for drug products does not include specific test methods.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not established, written and followed.
Test methods
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established.
Aseptic Processing Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written program not followed
The written stability testing program is not followed.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness and compliance with established standards.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Label storage access limited to authorized personnel
Access to the storage area for labels and labeling materials is not limited to authorized personnel.
Show 1 more citation
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the sterilization process.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Show 5 more citations
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness and compliance with established standards.
Test methods
The specificity of test methods have not been documented.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent that would alter the safety, identity, strength, quality or purity of the drug product.
Equipment for Environmental Control
Equipment for adequate control over air pressure is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Measured components for manufacturing
Components for drug product manufacturing are not measured and subdivided as appropriate.
Equipment for Environmental Control
Equipment for adequate control over micro-organisms is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Show 1 more citation
Written procedures lacking for use of pesticides etc.
Written procedures are lacking for the use of cleaning and sanitizing agents designed to prevent the contamination of equipment and components.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Lab controls established, including changes
The establishment of laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
Record maintenance 1 year (except exempt OTC)
All records of production and control associated with a batch of drug product were not maintained at least one (1) year after the expiration date.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Returned drug products identified and held
Returned drug products are not identified as such.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.
Label storage access limited to authorized personnel
Access to the storage area for labels and labeling materials is not limited to authorized personnel.
Calibration/Inspection/Checking not done
Routine calibration and checking of mechanical equipment is not performed according to a written program designed to assure proper performance.
Show 2 more citations
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature so that their identity, strength, quality, and purity are not affected.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Electronic records are used, but they do not meet system access limitation requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
- NAINo objectionable conditions that need follow-upDevices · Compliance: Devices4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Records reviewed annually
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
No written record of investigation
Written records are not made of investigations into the failure of a batch or any of its components to meet specifications.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.
- NAINo objectionable conditions that need follow-upDevices · Postmarket Assurance: Devices10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Certificates of Testing (Containers, Closures)
Certificates of testing of containers and closures are accepted in lieu of testing without establishing the reliability of the supplier's test results through appropriate validation of the test results at appropriate intervals.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.
Stability sample storage conditions described
The written stability program for drug products does not describe the storage conditions for samples retained for testing.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Show 5 more citations
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Aseptic Processing Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Adequate lab facilities not available
Adequate lab facilities for testing and approval or rejection of components, drug product containers, closures, and drug products are not available to the quality control unit.
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Report of Death or Serious Injury
An MDR report was not submitted within 30 days of receiving or otherwise becoming aware of information that reasonably suggests that a marketed device may have caused or contributed to a death or serious injury.
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Postmarket Assurance: Devices11 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Rejecting When Specifications Not Met
Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Valid stability test methods
The written stability program for drug products does not include reliable, meaningful, and specific test methods.
Show 6 more citations
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Adequate lab facilities not available
Adequate lab facilities for testing and approval or rejection of components are not available to the quality control unit.
Report of Death or Serious Injury
An MDR report was not submitted within 30 days of receiving or otherwise becoming aware of information that reasonably suggests that a marketed device may have caused or contributed to a death or serious injury.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, packing, and holding of a drug product lack the training required to perform their assigned functions.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size, and suitably located to facilitate operations for its intended use.
Lack of or inadequate procedures
Procedures for corrective and preventive action have not been established.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDevices · Compliance: Devices11 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Testing and standardization of standards et. al.
Laboratory records do not include complete records of any testing and standardization of laboratory.
Extent of discrepancy, failure investigations
Investigations of an unexplained discrepancy did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Investigation procedures
The corrective and preventive action procedures addressing the investigation of the cause of nonconformities relating to product, processes, and the quality system were not implemented.
Written calibration procedures
Written calibration procedures for instruments, apparatus, gauges, and recording devices are deficient in that they do not include specific limits for accuracy and precision and provisions for remedial action if limits are not met.
Show 6 more citations
Lack of or inadequate process validation
A process whose results cannot be fully verified by subsequent inspection and test has not been validated and approved according to established procedures.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Lab controls established, including changes
The establishment of test procedures and laboratory control mechanisms including any changes thereto, are not reviewed and approved by the quality control unit.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Nine requests to FDA under the Freedom of Information Act named this site, most recently on May 19, 2026. Each one asked for a Form 483.
Inspection ending Feb 13, 2026OAI
3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Apr 23, 2026. FDAgent holds no copy that FDA posted.
- May 19, 2026FDA-FOIA-2026-5136Form 483· 1 of 3 sitesRecords released
- Apr 10, 2026FDA-FOIA-2026-3604Form 483Records released
- Apr 9, 2026FDA-FOIA-2026-3589Form 483· 1 of 5 sitesRecords released
Inspection ending Aug 28, 2024VAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Apr 14, 2026. FDAgent holds no copy that FDA posted.
- Apr 8, 2026FDA-FOIA-2026-3463Form 483Records released
- Nov 6, 2024FDA-FOIA-2024-9862Form 483· 1 of 2 sitesClosed
Inspection ending Feb 13, 2023OAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Apr 23, 2026. FDAgent holds no copy that FDA posted.
- Apr 8, 2026FDA-FOIA-2026-3462Form 483Records released
- Jan 22, 2024FDA-FOIA-2024-708Form 483Closed
Inspection ending Dec 30, 2009OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Jul 16, 2024FDA-FOIA-2024-6254Form 483Closed
Inspection date not given
1 request. FDA released records in answer to a request for its Form 483 on Sep 9, 2025. FDAgent holds no copy that FDA posted.
- Jul 21, 2025FDA-FOIA-2025-8894Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 29 sections of 21 CFR in FDA’s published citations for this facility’s 11 inspections, with how many of them cited each.
- 21 CFR 211.113Control of microbiological contamination9 of 11
- 21 CFR 211.192Production record review7 of 11
- 21 CFR 211.22Responsibilities of quality control unit5 of 11
- 21 CFR 211.160General requirements5 of 11
- 21 CFR 211.42Design and construction features4 of 11
- 21 CFR 211.63Equipment design, size, and location4 of 11
- 21 CFR 211.110Sampling and testing of in-process materials and drug products4 of 11
- 21 CFR 211.166Stability testing4 of 11
Show all 29
- 21 CFR 211.194Laboratory records4 of 11
- 21 CFR 211.68Automatic, mechanical, and electronic equipment3 of 11
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures3 of 11
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling2 of 11
- 21 CFR 211.67Equipment cleaning and maintenance2 of 11
- 21 CFR 211.100Written procedures; deviations2 of 11
- 21 CFR 211.122Materials examination and usage criteria2 of 11
- 21 CFR 211.165Testing and release for distribution2 of 11
- 21 CFR 211.180General requirements2 of 11
- 21 CFR 211.198Complaint files2 of 11
- 21 CFR 803.50If I am a manufacturer, what reporting requirements apply to me?2 of 11
- 21 CFR 820.100Corrective and preventive action2 of 11
- 21 CFR 211.25Personnel qualifications1 of 11
- 21 CFR 211.56Sanitation1 of 11
- 21 CFR 211.101Charge-in of components1 of 11
- 21 CFR 211.142Warehousing procedures1 of 11
- 21 CFR 211.170Reserve samples1 of 11
- 21 CFR 211.182Equipment cleaning and use log1 of 11
- 21 CFR 211.188Batch production and control records1 of 11
- 21 CFR 211.204Returned drug products1 of 11
- 21 CFR 820.75Process validation1 of 11
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · Division of Pharmaceutical Quality Operations IV · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDRH · DevicesFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Packing, labeling
- Registration runs through
- Dec 31, 2027
- Registrant
- KC Pharmaceuticals, Inc.D-U-N-S 174450460
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 2026940 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 2026940. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.