Skip to content

BPI Labs

97 S Red Willow Rd, Evanston, Wyoming, United States

FEI 3008875046DUNS 197130958

Company: Ally Labs · Linked by exact D-U-N-S match (197130958) in FDA registration data

FDA has 2 inspections on file for BPI Labs in Evanston, Wyoming (FEI 3008875046), from 2019 to 2022. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 12 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is BPI Labs, DBA Ally Labs (D-U-N-S 197130958).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2019–2022
0 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
2 requests, latest Jul 16, 2024
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance12 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Records reviewed annually

      Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.

    2. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    3. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and written.

    4. Representative Samples Criteria

      The number of containers to be sampled is not based upon appropriate criteria.

    5. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    Show 7 more citations
    1. Identification of Equipment and Lines

      The batch production and control records are deficient in that they do not include the identity of major equipment used.

    2. Strict control not exercised over labeling issued

      Strict control is not exercised over labeling issued for use in drug product labeling operations.

    3. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function and current good manufacturing practices.

    4. Stability sample storage conditions described

      The written stability program for drug products does not describe the storage conditions for samples retained for testing.

    5. Lab controls established, including changes

      The establishment of laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit. Electronic records are used, but they do not meet system access limitation, audit trail, systems documentation control, signature manifestation and signature to record linking requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.

    6. Approve or reject procedures or specs

      The quality control unit lacks responsibility to approve all procedures or specifications impacting on the identity, strength, quality and purity of drug products.

    7. Actual vs. theoretical yields not determined

      Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing of the drug product.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices13 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lack/Inad procedure-Monitoring/Control of Validated Proces

      Procedures for monitoring and control of process parameters for a validated process have not been established.

    2. Lack of or inadequate receiving acceptance procedures

      Procedures for acceptance of incoming product have not been established.

    3. Lack of Written MDR Procedures

      Written MDR procedures have not been developed.

    4. DHR - not or inadequately maintained

      A device history record has not been adequately maintained.

    5. Purchasing controls, Lack of or inadequate procedures

      Procedures to ensure that all purchased or otherwise received product and services conform to specified requirements have not been established.

    Show 8 more citations
    1. Lack of or inadequate procedures

      Procedures for corrective and preventive action have not been established.

    2. Training records

      Personnel training is not documented.

    3. Environmental control Lack of or inadequate procedures

      Procedures to control environmental conditions have not been adequately established.

    4. Design changes - Lack of or Inadequate Procedures

      Procedures for design change have not been established.

    5. Equipment control activity documentation

      Equipment maintenance activities have not been documented.

    6. Quality audits - Lack of or inadequate procedures

      Procedures for quality audits have not been established.

    7. Lack of procedures, or not maintained

      Document control procedures have not been established.

    8. Management review - Lack of or inadequate procedures

      Procedures for management review have not been established.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 16, 2024. Each one asked for a Form 483.

  • Inspection ending Mar 10, 2022VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Apr 27, 2022FDA-FOIA-2022-3028Form 483Closed
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. Jul 16, 2024FDA-FOIA-2024-6213Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 24 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.

Show all 24

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2026
Registrant
BPI Labs, DBA Ally LabsD-U-N-S 197130958

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3008875046 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3008875046. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.