Skip to content

Chemisphere Corporation

2101 Clifton Ave, Saint Louis, Missouri, United States

FEI 1000158477DUNS 071957146

FDA has 5 inspections on file for Chemisphere Corporation in Saint Louis, Missouri (FEI 1000158477), from 2010 to 2025. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. Three FOIA requests have asked FDA for this inspection's 483.

No court action or import refusal is filed under this FEI.

Six regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and API manufacturing, through Dec 31, 2026. Its registrant is Chemisphere Corporation (D-U-N-S 071957146).

Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
5, 2010–2025
1 OAI · 3 VAI · 1 NAI
Inspections with 483 observations shown
2 of 5
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
3 requests, latest May 14, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices20 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

    2. Identity Testing of Each Component

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.

    3. Status of Each Lot Identified

      Each lot of components was not appropriately identified as to its status in terms of being quarantined, approved or rejected.

    4. Following/documenting laboratory controls

      Established test procedures are not documented at the time of performance.

    5. Buildings not maintained in good state of repair

      Buildings used in the manufacturing and holding of a drug product are not maintained in a good state of repair.

    Show 15 more citations
    1. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    2. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    3. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    4. Weights and measures of components used

      Batch production and control records do not include the weights and measures of components used in the course of processing each batch of drug product produced.

    5. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the handling and sampling of components.

    6. Actual vs. theoretical yields not determined

      Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing of the drug product.

    7. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    8. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    9. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    10. Calibration/Inspection/Checking not done

      Routine calibration of electronic equipment is not performed according to a written program designed to assure proper performance.

    11. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

    12. Establish reliability of supplier's C of A

      Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.

    13. Microbiological Contamination Exam

      Each lot of a component that is liable to microbiological contamination that is objectionable in view of its intended use is not subjected to microbiological tests before use.

    14. Design changes - Lack of or Inadequate Procedures

      Procedures for design change have not been adequately established.

    15. Identification procedures, Lack of or inadequate procedures

      Procedures for identifying product during all stages of receipt, production, distribution, and installation have not been adequately established.

  5. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices15 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Signature and checking of records -- 2 persons

      The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.

    2. Cleaning/maintenance records not kept

      Records are not kept for the cleaning and inspection of equipment.

    3. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

    4. Following/documenting laboratory controls

      Established test procedures are not documented at the time of performance.

    5. Test methods

      The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented.

    Show 10 more citations
    1. Quality System Procedures

      Quality system procedures were not implemented.

    2. Second person sign off

      Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.

    3. Design changes - Lack of or Inadequate Procedures

      Procedures were not established for the identification, documentation, validation or verification, review, and approval of design changes before their implementation.

    4. Written distribution procedure

      Written distribution procedures are not established.

    5. Component identification test

      Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.

    6. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    7. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    8. Theoretical Yield and Percentages

      The master production and control records are deficient in that they do not include a statement of theoretical yield and yield percentages.

    9. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    10. Lack of or inadequate process validation

      A process whose results cannot be fully verified by subsequent inspection and test has not been validated and approved according to established procedures.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on May 14, 2026. Each one asked for a Form 483.

  • Inspection ending Jun 24, 2025OAI

    3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Sep 23, 2025. FDAgent holds no copy that FDA posted.

    1. May 14, 2026FDA-FOIA-2026-4949Form 483· 1 of 5 sitesWithdrawn
    2. Sep 30, 2025FDA-FOIA-2025-11441Form 483Records released
    3. Aug 26, 2025FDA-FOIA-2025-10177Form 483· 1 of 5 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 21 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 5 inspections, with how many of them cited each.

Show all 21

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, API manufacturing
Registration runs through
Dec 31, 2026
Registrant
Chemisphere CorporationD-U-N-S 071957146

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1000158477 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1000158477. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.