Skip to content

WAVi Co.

3857 N Steele St Ste 1293, Denver, Colorado, United States

FEI 3013757456

FDA has 4 inspections on file for WAVi Co. in Denver, Colorado (FEI 3013757456), from 2018 to 2023. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDRH · Division of Medical Device and Radiological Health Operations West).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 9 citations from this inspection, all under 21 CFR Part 820, the device quality system rules. They are listed below.

No court action or import refusal is filed under this FEI.

Eight regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
4, 2018–2023
1 OAI · 1 VAI · 2 NAI
Inspections with 483 observations shown
4 of 4
Form 483s posted by FDA
None held for this FEI
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDevices · Compliance: Devices9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lack of or inadequate process validation

      A process whose results cannot be fully verified by subsequent inspection and test has not been validated according to established procedures.

    2. Quality audits - Lack of or inadequate procedures

      Procedures for quality audits have not been adequately established.

    3. Lack of or inadequate procedures - Acceptance activities

      Procedures for acceptance activities have not been adequately established.

    4. Calibration, Inspection, etc. Procedures Lack of or Inadequ

      Procedures to ensure equipment is routinely calibrated, inspected and maintained have not been adequately established.

    5. Procedures not adequately established or maintained

      Document control procedures have not been adequately established.

    Show 4 more citations
    1. Lack of or inadequate complaint procedures

      Procedures for receiving, reviewing, and evaluating complaints by a formally designated unit have not been adequately established.

    2. Lack of or inadequate procedures

      Procedures for corrective and preventive action have not been adequately established.

    3. DHR - not or inadequately maintained

      A device history record has not been adequately maintained.

    4. Design validation - software validation not performed

      Validation of device software was not performed.

  2. NAINo objectionable conditions that need follow-upDevices · Postmarket Assurance: Devices4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lack of or inadequate procedures

      Procedures for corrective and preventive action have not been adequately established.

    2. Process control procedures, Lack of or inadequate procedures

      Process control procedures that describe any process controls necessary to ensure conformance to specifications have not been adequately established.

    3. Management representative

      No management representative had been appointed to ensure that quality system requirements are met, and to report to management on the performance of the quality system.

    4. Statistical techniques - Lack of or inadequate procedures

      Procedures for identifying valid statistical techniques required for establishing, controlling, and verifying the acceptability of process capability and product characteristics have not been established.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Training - Lack of or inadequate procedures

      Procedures for training and identifying training needs have not been established.

    2. Design validation- Lack of or inadequate procedures

      Procedures for design validation have not been established.

    3. Purchasing controls, Lack of or inadequate procedures

      Procedures to ensure that all purchased or otherwise received product and services conform to specified requirements have not been established.

    4. Lack of or inadequate receiving acceptance procedures

      Procedures for acceptance of incoming product have not been established.

    5. Documentation

      In-process inspections, tests, or other verification activities and approvals were not documented.

    Show 2 more citations
    1. Lack of procedures, or not maintained

      Document control procedures have not been established.

    2. DMR - not or inadequately maintained

      A device master record has not been maintained.

  4. NAINo objectionable conditions that need follow-upDevices · Postmarket Assurance: Devices9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lack of or inadequate organizational structure

      The organizational structure has not been adequately established and maintained to ensure that devices are designed and produced in accordance with 21 CFR 820.

    2. Document locations, Dissemination, etc.

      Documents were not available at all locations for which they are designated, used, or otherwise necessary.

    3. Design history file

      The design history file does not demonstrate that the design was developed following the requirements of 21 CFR 820.

    4. Calibration, Inspection, etc. Procedures Lack of or Inadequ

      Procedures to ensure equipment is routinely calibrated, inspected and maintained have not been adequately established.

    5. Acceptable supplier records, inadequate records

      Records of acceptable suppliers have not been adequately established.

    Show 4 more citations
    1. Quality audits - Lack of or inadequate procedures

      Procedures for quality audits have not been adequately established.

    2. DHR content

      The device history record does not demonstrate that the device was manufactured in accordance with 21 CFR 820.

    3. DMR - not or inadequately maintained

      A device master record has not been adequately maintained.

    4. Lack of or inadequate procedures - Acceptance activities

      Procedures for acceptance activities have not been adequately established.

Regulations FDA cited here

The 15 sections of 21 CFR in FDA’s published citations for this facility’s 4 inspections, with how many of them cited each.

Show all 15

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3013757456 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3013757456. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.