Seaway Pharma Inc.
5 County Route 42, Massena, New York, United States
FEI 3012275336
FDA has 6 inspections on file for Seaway Pharma Inc. in Massena, New York (FEI 3012275336), from 2015 to 2025. The latest ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER · Office of Manufacturing Quality).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 11 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three of the seven FOIA requests for this site have asked FDA for this inspection's 483.
No court action or import refusal is filed under this FEI.
16 regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 6, 2015–2025
- 4 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 5 of 6
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 7 requests, latest FY2023
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance11 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Complete Test Data
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
Cleaning SOPs/instructions
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Following/documenting laboratory controls
Established laboratory control mechanisms are not followed.
Written program not followed
The written stability testing program is not followed.
Show 6 more citations
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Component identity verification
Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Calibration/Inspection/Checking not done
Routine inspection and checking of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Show 9 more citations
Cleaning SOPs/instructions
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
Stability sample storage conditions described
The written stability program for drug products does not describe the storage conditions for samples retained for testing.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls and returned or salvaged drug products.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Complete Test Data
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
Reserve samples identified, representative, stored
Reserve drug product samples are not retained and stored under conditions consistent with product labeling.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance11 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Buildings of Suitable Size, Construction, Location
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Results not used for expiration dates, storage cond.
Results of stability testing are not used in determining appropriate storage conditions and expiration dates.
Written in-process control procedures
Written procedures are not established and followed that describe the in-process controls and examinations to be conducted on appropriate samples of in-process materials of each batch.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.
Show 6 more citations
Calibration/Inspection/Checking not done
Routine calibration of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and written.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Following/documenting laboratory controls
Established laboratory control mechanisms are not followed and documented at the time of performance.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance16 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
Cleaning SOPs/instructions
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Sampling and testing plans not described
Sampling and testing plans for drug products are not described in written procedures which include the number of units per batch to be tested.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Show 11 more citations
Test methods
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
Packaging line inspection before use
Inspection of the packaging facilities immediately before use is not done to assure that all drug products have been removed from previous operations.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
Equipment for Environmental Control
Equipment for adequate control over air pressure is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Written program not followed
The written stability testing program is not followed.
Complete Test Data
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
Equipment construction - reactive surfaces
Equipment surfaces that contact in-process materials and drug products are reactive, additive or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements.
Clothing appropriate for duties performed
Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function.
Buildings not maintained in good state of repair
Buildings used in the manufacturing and holding of a drug product are not maintained in a good state of repair.
Identification of persons involved, each significant step
Batch production and control records do not include the identification of the persons performing each significant step in the operation, for each batch of drug product produced.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Buildings not maintained in good state of repair
Buildings used in the manufacturing, processing, packing, and holding of a drug product are not maintained in a good state of repair.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Equipment for Environmental Control
Equipment for adequate control over humidity and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not include the conclusions and follow-up.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Show 4 more citations
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Seven requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.
Inspection ending Jun 18, 2025OAI
3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Oct 3, 2025. FDAgent holds no copy that FDA posted.
- May 5, 2026FDA-FOIA-2026-4425Form 483· 1 of 5 sitesWithdrawn
- Jan 8, 2026FDA-FOIA-2026-245Form 483Records released
- Aug 30, 2025FDA-FOIA-2025-10453Form 483· 1 of 5 sitesRecords released
Inspection ending Sep 21, 2023OAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Dec 8, 2025. FDAgent holds no copy that FDA posted.
- Nov 28, 2025FDA-FOIA-2025-13355Form 483Records released
- Jan 23, 2024FDA-FOIA-2024-754Form 483Closed
Inspection ending Sep 15, 2021OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2023-5103Form 483Closed
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Aug 21, 2024FDA-FOIA-2024-7434Form 483· 1 of 3 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 25 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit5 of 5
- 21 CFR 211.67Equipment cleaning and maintenance5 of 5
- 21 CFR 211.166Stability testing4 of 5
- 21 CFR 211.192Production record review4 of 5
- 21 CFR 211.25Personnel qualifications3 of 5
- 21 CFR 211.56Sanitation3 of 5
- 21 CFR 211.100Written procedures; deviations3 of 5
- 21 CFR 211.160General requirements3 of 5
Show all 25
- 21 CFR 211.165Testing and release for distribution3 of 5
- 21 CFR 211.194Laboratory records3 of 5
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling2 of 5
- 21 CFR 211.58Maintenance2 of 5
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 5
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 5
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 5
- 21 CFR 211.28Personnel responsibilities1 of 5
- 21 CFR 211.42Design and construction features1 of 5
- 21 CFR 211.63Equipment design, size, and location1 of 5
- 21 CFR 211.65Equipment construction1 of 5
- 21 CFR 211.113Control of microbiological contamination1 of 5
- 21 CFR 211.130Packaging and labeling operations1 of 5
- 21 CFR 211.142Warehousing procedures1 of 5
- 21 CFR 211.170Reserve samples1 of 5
- 21 CFR 211.180General requirements1 of 5
- 21 CFR 211.188Batch production and control records1 of 5
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Office of Manufacturing Quality · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012275336 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012275336. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.