Power Line Packaging, Inc.
1304 Conshohocken Rd, Conshohocken, Pennsylvania, United States
FEI 3000718719
FDA has 3 inspections on file for Power Line Packaging, Inc. in Conshohocken, Pennsylvania (FEI 3000718719), from 2010 to 2016. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.
No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.160(b)(3).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2010–2016
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include maintenance and cleaning schedules.
Acceptance of drug products
Determinations of conformance to appropriate written specifications for acceptance are deficient for drug products.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function and written procedures required by current good manufacturing practice regulations.
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices25 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Sample identification and other information
Laboratory records do not include a description of the sample received for testing, the source or location from where the sample was obtained, the quantity of the sample, the date the sample was taken, and the date the sample was received for testing.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Procedures are written, and followed
Procedures designed to assure that correct labels, labeling, and packaging materials are used for drug products are not written.
Written records kept in individual logs
Written records of major equipment maintenance and use are not included in individual equipment logs.
Examination of packaging and labeling
Examination of packaging and labeling materials for suitability and correctness before packaging operations is not documented in the batch production records.
Show 20 more citations
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the identification and testing of components.
Labeling control records including specimens or copies
Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.
Cleaning/maintenance records not kept
Records are not kept for the cleaning and sanitizing of equipment.
Distinctive ID or code not recorded in batch record
The batch records do not record the distinctive identification number to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.
Investigations made into any unexplained discrepancy
Batch production and control records do not include the results of any investigation made into any unexplained discrepancy, whether or not the batch of drug product had already been distributed.
Personnel dating/signing equipment log
The persons double-checking the cleaning and maintenance are not dating and signing or initialing the equipment cleaning and use log.
In-process samples representative, identified properly
Samples taken of in-process materials for determination of conformance to specifications are not representative.
Drug products - samples representative, identified properly
Samples taken of drug products for determination of conformance to written specifications are not representative.
Identification of persons involved, each significant step
Batch production and control records do not include the identification of the persons performing, directly supervising, and checking each significant step in the operation, for each batch of drug product produced.
Microbiological Contamination Exam
Each lot of a component that is liable to microbiological contamination that is objectionable in view of its intended use is not subjected to microbiological tests before use.
Defined areas of adequate size for operations
The separate or defined areas necessary to prevent contamination or mix-ups are deficient.
Environmental control Lack of or inadequate procedures
Appropriate procedures have not been defined for controlling environmental conditions.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design and of adequate size to facilitate operations for its intended use and cleaning and maintenance.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.
Status of Each Lot Identified
Each lot of components and drug product containers was not appropriately identified as to its status in terms of being quarantined, approved or rejected.
Documentation
Process validation activities and results have not been documented.
Exhaust systems inadequate to control air contamination
Adequate exhaust systems or other systems to control contaminants are lacking in areas where air contamination occurs during production.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded and justified.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Regulations FDA cited here
The 17 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.67Equipment cleaning and maintenance2 of 2
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 2
- 21 CFR 211.63Equipment design, size, and location1 of 2
- 21 CFR 211.80General requirements1 of 2
Show all 17
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.105Equipment identification1 of 2
- 21 CFR 211.130Packaging and labeling operations1 of 2
- 21 CFR 211.182Equipment cleaning and use log1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
- 21 CFR 211.194Laboratory records1 of 2
- 21 CFR 820.70Production and process controls1 of 2
- 21 CFR 820.75Process validation1 of 2
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3000718719 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3000718719. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.