Citra Labs, LLC
55 Messina Dr, Braintree, Massachusetts, United States
FEI 1216032DUNS 962863838
FDA has 7 inspections on file for Citra Labs, LLC in Braintree, Massachusetts (FEI 1216032), from 2009 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One FOIA request has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant is Citra Labs, LLC (D-U-N-S 962863838).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 7, 2009–2024
- 0 OAI · 6 VAI · 1 NAI
- Inspections with 483 observations shown
- 4 of 7
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 1 request, latest May 24, 2024
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Buildings not maintained in good state of repair
Buildings used in the manufacturing of a drug product are not maintained in a good state of repair.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
SOPs not followed / documented
Written production and process control procedures are not documented at the time of performance.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance and use are not included in individual equipment logs.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete manufacturing, control, instructions and specifications.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Components withheld from use pending release
Each lot of components and drug product containers is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
Buildings of Suitable Size, Construction, Location
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable size, construction, and location to facilitate cleaning, maintenance, and proper operations.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices19 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Containers & Closures Clean, Sterilized, Pyrogen-free
Drug product closures were not sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.
Show 14 more citations
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Representative Samples
Representative samples are not taken of each shipment of each lot of components for testing or examination.
Buildings not maintained in good state of repair
Buildings used in the packing and holding of a drug product are not maintained in a good state of repair.
Product flow through building is inadequate
The flow of components, drug product containers, and closures though the building is not designed to prevent contamination.
Equipment for Environmental Control
Equipment for adequate control over air pressure and dust is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the testing, approval, and rejection of closures.
Training , Education , Experience overall
Employees engaged in the manufacture and processing of a drug product lack the education, training, and experience required to perform their assigned functions.
Calibration/Inspection/Checking not done
Routine inspection and checking of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Written calibration / inspection records not kept
Records of the calibration checks and inspections of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.
Test methods
The sensitivity and reproducibility of test methods have not been established and documented.
In-Process and Laboratory Control Results
The batch production and control records are deficient in that they do not include in-process control results.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components, drug product containers, and closures at all times in a manner to prevent contamination.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on May 24, 2024. It asked for a Form 483.
Inspection ending Mar 8, 2024VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- May 24, 2024FDA-FOIA-2024-4636Form 483· 1 of 4 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 19 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features3 of 4
- 21 CFR 211.58Maintenance2 of 4
- 21 CFR 211.67Equipment cleaning and maintenance2 of 4
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 4
- 21 CFR 211.100Written procedures; deviations2 of 4
- 21 CFR 211.160General requirements2 of 4
- 21 CFR 211.192Production record review2 of 4
- 21 CFR 211.22Responsibilities of quality control unit1 of 4
Show all 19
- 21 CFR 211.25Personnel qualifications1 of 4
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 4
- 21 CFR 211.63Equipment design, size, and location1 of 4
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 4
- 21 CFR 211.80General requirements1 of 4
- 21 CFR 211.94Drug product containers and closures1 of 4
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 4
- 21 CFR 211.165Testing and release for distribution1 of 4
- 21 CFR 211.182Equipment cleaning and use log1 of 4
- 21 CFR 211.186Master production and control records1 of 4
- 21 CFR 211.188Batch production and control records1 of 4
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- Citra Labs, LLCD-U-N-S 962863838
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1216032 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1216032. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.