Exactech, Inc.

2320 Nw 66th Ct, Gainesville, Florida, United States

FEI 1038671

FDA has 14 inspections on file for Exactech, Inc. in Gainesville, Florida (FEI 1038671), from 2008 to 2025. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 9 citations from this inspection, all under 21 CFR Part 820, the device quality system rules. They are listed below. Two of the seven FOIA requests for this site have asked FDA for this inspection's 483.

FDA issued a warning letter on (CDRH). No court action or import refusal is filed under this FEI.

Seven regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
14, 2008–2025
2 OAI · 5 VAI · 7 NAI
Inspections with 483 observations shown
5 of 14
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
7 requests, latest FY2023
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

14 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDevices · Compliance: Devices9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lack of or inadequate process validation

      A process whose results cannot be fully verified by subsequent inspection and test has not been validated according to established procedures.

    2. Purchasing controls, Lack of or inadequate procedures

      Procedures to ensure that all purchased or otherwise received product and services conform to specified requirements have not been adequately established.

    3. Lack of or inadequate procedures

      Procedures for corrective and preventive action have not been adequately established.

    4. Design Validation - Risk analysis not performed/inadequate

      Risk analysis is inadequate and is incomplete.

    5. Design input - documentation

      Design input requirements were not adequately documented.

    Show 4 more citations
    1. Design verification - output does not meet input requirement

      Design verification does not confirm that design output meets design input requirements.

    2. DMR - not or inadequately maintained

      A device master record has not been adequately maintained.

    3. Process changes - review, evaluation and revalidation

      A validated process was not reviewed and evaluated and revalidated when changes or process deviations occurred.

    4. Production and Process Change Procedures, lack of or Inad.

      Procedures for changes to a specification have not been adequately established.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Postmarket Assurance: DevicesCitations not published
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDevices · Postmarket Assurance: Devices2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Report of Death or Serious Injury

      An MDR report was not submitted within 30 days of receiving or otherwise becoming aware of information that reasonably suggests that a marketed device may have caused or contributed to a death or serious injury.

    2. Lack of or inadequate procedures

      Procedures for corrective and preventive action have not been adequately established.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Sampling plans

      Sampling plans are not based on valid statistical rationale.

    2. Lack of or inadequate process validation

      A process whose results cannot be fully verified by subsequent inspection and test has not been adequately validated according to established procedures.

    3. Lack of or inadequate receiving acceptance procedures

      Procedures for acceptance of incoming product have not been established.

    4. Incorrect translation to production specifications

      The device design was not correctly translated into production specifications.

  5. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Design Validation - Risk analysis not performed/inadequate

      Risk analysis is incomplete.

    2. Purchasing controls, Lack of or inadequate procedures

      Procedures to ensure that all purchased or otherwise received product and services conform to specified requirements have not been adequately established.

    3. Lack of or inadequate procedures

      Procedures for corrective and preventive action have not been adequately established.

    4. Nonconforming product, Lack of or inadequate procedures

      Procedures have not been adequately established to control product that does not conform to specified requirements.

    5. Design verification - Lack of or inadequate procedures

      Procedures for design verification have not been adequately established.

    Show 2 more citations
    1. Design transfer - Lack of or inadequate procedures

      Procedures for design transfer have not been adequately established.

    2. Design validation- Lack of or inadequate procedures

      Procedures for design validation have not been adequately established.

  6. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  7. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lack of or inadequate complaint procedures

      Procedures for receiving, reviewing, and evaluating complaints by a formally designated unit have not been adequately established.

    2. Design Validation - Risk analysis not performed/inadequate

      Risk analysis is incomplete.

    3. Purchasing controls, Lack of or inadequate procedures

      Procedures to ensure that all purchased or otherwise received product and services conform to specified requirements have not been adequately established.

    4. Lack of or inadequate procedures

      Procedures for corrective and preventive action have not been adequately established.

    5. Report of Death or Serious Injury

      An MDR report was not submitted within 30 days of receiving or otherwise becoming aware of information that reasonably suggests that a marketed device may have caused or contributed to a death or serious injury.

    Show 2 more citations
    1. Design validation- Lack of or inadequate procedures

      Procedures for design validation have not been adequately established.

    2. Training - Lack of or inadequate procedures

      Procedures for training and identifying training needs have not been adequately established.

  8. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
  9. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  10. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
  11. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  12. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  13. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Project Evaluation: DevicesCitations not published
  14. NAINo objectionable conditions that need follow-upDevices · Postmarket Assurance: DevicesNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Seven requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.

  • Inspection ending Aug 27, 2025OAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Dec 3, 2025. FDAgent holds no copy that FDA posted.

    1. Feb 10, 2026FDA-FOIA-2026-1396Form 483Records released
    2. Sep 30, 2025FDA-FOIA-2025-11466Form 483· 1 of 5 sitesRecords released
  • Inspection ending Oct 9, 2024VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Mar 4, 2025FDA-FOIA-2025-1940Form 483· 1 of 4 sitesClosed
  • Inspection ending Sep 26, 2023OAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Feb 27, 2026. FDAgent holds no copy that FDA posted.

    1. Feb 27, 2026FDA-FOIA-2026-2028Form 483Records released
    2. Jan 23, 2024FDA-FOIA-2024-750Form 483Closed
  • Inspection ending Jan 31, 2020VAI

    1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on May 14, 2026. FDAgent holds no copy that FDA posted.

    1. Apr 14, 2026FDA-FOIA-2026-3761Form 483Records released
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-7765Inspection recordsClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 12 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 14 inspections, with how many of them cited each.

Show all 12

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1038671 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1038671. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.