Skip to content

Mixpak Inc

1571 & 1577 W 132nd St, Gardena, California, United States

FEI 2013263

FDA has 3 inspections on file for Mixpak Inc in Gardena, California (FEI 2013263), from 2008 to 2012. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 5 citations from this inspection: 3 under 21 CFR Part 211, the manufacturing rules for finished drugs, and 2 under 21 CFR Part 820, the device quality system rules. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Nine regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2008–2012
0 OAI · 3 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. GMP Training Frequency

      GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.

    2. Lack of or inadequate final acceptance procedures

      Procedures for finished device acceptance have not been adequately established.

    3. Documentation

      Process validation results have not been adequately approved.

    4. Quality control unit review of records

      Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.

    5. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices17 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. DMR - not or inadequately maintained

      A device master record has not been maintained.

    2. Lack of or inadequate DHR procedures

      Procedures for device history records have not been established.

    3. Lack of or inadequate complaint procedures

      Procedures for receiving, reviewing, and evaluating complaints by a formally designated unit have not been established.

    4. Lack of or inadequate procedures for labeling

      Procedures to control labeling activities have not been established.

    5. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    Show 12 more citations
    1. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include maintenance and cleaning schedules, description in sufficient detail of methods, equipment and materials used, description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance, and instructions for removal or obliteration of previous batch identification.

    2. GMP Training Frequency

      GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.

    3. Lack of or inadequate procedures

      Procedures for corrective and preventive action have not been established.

    4. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    5. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design and suitably located to facilitate operations for its intended use.

    6. Written records kept in individual logs

      Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.

    7. Procedures to be written and followed

      Procedures describing the handling of all written and oral complaints regarding a drug product are not written and followed.

    8. Lack of or inadequate final acceptance procedures

      Procedures for finished device acceptance have not been established.

    9. Lack of Written MDR Procedures

      Written MDR procedures have not been developed and implemented.

    10. Procedures are written, and followed

      Procedures designed to assure that correct labels and packaging materials are used for drug products are not written.

    11. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of drug product containers and closures.

    12. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    2. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    3. Procedures are written, and followed

      Procedures designed to assure that correct labels and packaging materials are used for drug products are not written.

    4. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include maintenance and cleaning schedules, description in sufficient detail of methods, equipment and materials used, description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance, and instructions for removal or obliteration of previous batch identification.

    5. Written records kept in individual logs

      Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.

    Show 1 more citation
    1. Procedures to be written and followed

      Procedures describing the handling of all written and oral complaints regarding a drug product are not established and written.

Regulations FDA cited here

The 18 sections of 21 CFR in FDA’s published citations for this facility’s 3 inspections, with how many of them cited each.

Show all 18

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 2013263 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 2013263. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.