King Bio Inc.
3 Westside Dr, Asheville, North Carolina, United States
FEI 1053442DUNS 617901350
FDA has 8 inspections on file for King Bio Inc. in Asheville, North Carolina (FEI 1053442), from 2011 to 2023. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 2 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One FOIA request has asked FDA for this inspection's 483.
The most recent OAI inspection ended on Jul 20, 2018. FDA has issued 2 warning letters under this FEI, the latest on (CDER). No court action or import refusal is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and API manufacturing, through Dec 31, 2027. Its registrant is King Bio Inc (D-U-N-S 617901350).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 8, 2011–2023
- 1 OAI · 5 VAI · 2 NAI
- Inspections with 483 observations shown
- 4 of 8
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 1 request, latest Oct 31, 2023
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function.
Component identification test
Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.
Written record of investigation incomplete
Written records of investigations into do not include the conclusions and follow-up.
Show 2 more citations
Individual inventory record
Records fail to include an individual inventory record of each component, reconciliation of the use of each component, drug product container and drug product closure with sufficient information to allow determination of any associated batch or lot of drug product.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Penicillin air handling systems not kept separate
Air-handling systems for the of penicillin are not completely separate from those for other drug products for human use.
Personnel dating/signing equipment log
The persons double-checking the cleaning and maintenance are not dating and signing or initialing the equipment cleaning and use log.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Failing to test for penicillin cross-contamination
Non-penicillin drug products were not tested for the presence of penicillin, when a reasonable possibility existed that a non-penicillin drug product has been exposed to a cross-contamination with penicillin.
Show 9 more citations
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy and compliance with established standards.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, in-process materials, and drug products conform to appropriate standards of identity, strength, quality and purity.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Testing of reconstituted drugs
The written stability program does not include testing of drug products for reconstitution after they are reconstituted.
In-Process Material Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the storage of in-process materials.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, and holding of a drug product lack the training required to perform their assigned functions.
Penicillin processing area not kept separate
The operations relating to the manufacture, processing, and packing of penicillin are not performed in facilities separate from those used for other drug products for human use.
Active ingredient retained sample kept
A sample which is representative of each lot in each shipment of each active ingredient is not retained.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete testing and procedures.
Written program not followed
The written stability testing program is not followed.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Rejecting When Specifications Not Met
Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.
Show 1 more citation
Training , Education , Experience overall
Employees engaged in the processing of a drug product lack the education and training required to perform their assigned functions.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Oct 31, 2023. It asked for a Form 483.
Inspection ending Jul 28, 2023VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Oct 31, 2023FDA-FOIA-2023-9559Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 21 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 8 inspections, with how many of them cited each.
- 21 CFR 211.25Personnel qualifications3 of 4
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures3 of 4
- 21 CFR 211.166Stability testing2 of 4
- 21 CFR 211.192Production record review2 of 4
- 21 CFR 211.22Responsibilities of quality control unit1 of 4
- 21 CFR 211.42Design and construction features1 of 4
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 4
- 21 CFR 211.63Equipment design, size, and location1 of 4
Show all 21
- 21 CFR 211.67Equipment cleaning and maintenance1 of 4
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 4
- 21 CFR 211.111Time limitations on production1 of 4
- 21 CFR 211.113Control of microbiological contamination1 of 4
- 21 CFR 211.160General requirements1 of 4
- 21 CFR 211.165Testing and release for distribution1 of 4
- 21 CFR 211.170Reserve samples1 of 4
- 21 CFR 211.176Penicillin contamination1 of 4
- 21 CFR 211.182Equipment cleaning and use log1 of 4
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 4
- 21 CFR 211.186Master production and control records1 of 4
- 21 CFR 211.188Batch production and control records1 of 4
- 21 CFR 211.194Laboratory records1 of 4
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, API manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- King Bio IncD-U-N-S 617901350
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1053442 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1053442. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.