Skip to content

Melaleuca Inc

735 W 25th St, Idaho Falls, Idaho, United States

FEI 3021937DUNS 079711683

FDA has 6 inspections on file for Melaleuca Inc in Idaho Falls, Idaho (FEI 3021937), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 5 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two FOIA requests have asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Four regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is Melaleuca, Inc. (D-U-N-S 079711683).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
6, 2009–2025
0 OAI · 6 VAI · 0 NAI
Inspections with 483 observations shown
5 of 6
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
2 requests, latest May 4, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Component identification test

      Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.

    2. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.

    3. Calibration/Inspection/Checking not done

      Routine calibration of automatic and electronic equipment is not performed according to a written program designed to assure proper performance.

    4. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    5. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    2. Establishment of calibration procedures

      Procedures describing the calibration of instruments, apparatus, gauges and recording devices are deficiently written or followed.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Unapproved and Misbranded DrugsCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Complaint Record required information

      Complaint records are deficient in that they do not include the known lot number and nature of complaint.

    2. Rejecting When Specifications Not Met

      Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.

    3. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not recorded and justified.

    4. Approve or reject procedures or specs

      The quality control unit lacks responsibility to approve all procedures or specifications impacting on the quality of drug products.

    5. Second person sign off

      Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.

  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    2. Equipment construction - reactive surfaces

      Equipment surfaces that contact components, in-process materials, and drug products are reactive, additive or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements.

    3. Calibration - at intervals, written program, remedial action

      The calibration of instruments is not done at suitable intervals .

    4. Review of representative number of batches

      Written procedures are not established for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    5. Released Drug Products Area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the storage of drug products after release.

    Show 3 more citations
    1. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not written.

    2. Buildings not maintained in good state of repair

      Buildings used in the manufacturing, processing, packing, and holding of a drug product are not maintained in a good state of repair.

    3. Component identity verification

      Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.

  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    2. Labeling control records including specimens or copies

      Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.

    3. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

    4. Acceptance criteria for sampling & testing

      Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet appropriate statistical quality control criteria as a condition for their approval and release.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on May 4, 2026. Each one asked for a Form 483.

  • Inspection ending Aug 27, 2025VAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Nov 25, 2025. FDAgent holds no copy that FDA posted.

    1. May 4, 2026FDA-FOIA-2026-4387Form 483· 1 of 5 sitesRecords released
    2. Nov 4, 2025FDA-FOIA-2025-12586Form 483· 1 of 5 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 16 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 6 inspections, with how many of them cited each.

Show all 16

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2026
Registrant
Melaleuca, Inc.D-U-N-S 079711683

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other FEIs recorded as Melaleuca Inc

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

  • Melaleuca IncFEI 1000151121Knoxville, Tennessee, United States

    Last inspected 2025-05-14VAI

  • Melaleuca IncFEI 3022798Idaho Falls, Idaho, United States

    Last inspected 2011-11-02NAI

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3021937 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3021937. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.