FDA has 5 inspections on file for Central Admixture Pharmacy Services Inc in Allentown, Pennsylvania (FEI 3009590582), from 2014 to 2025. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDA published 5 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.

FDA has issued 3 warning letters under this FEI, the latest on (CDER · Division of Pharmaceutical Quality Operations I). No court action or import refusal is filed under this FEI.

Six regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
5, 2014–2025
4 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
5 of 5
3 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
6 posted
Requested under FOIA
2 requests, latest Dec 4, 2025
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Test methods

      The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.

    2. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.

    3. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    5. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.

    2. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    3. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.

    4. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and followed.

    5. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    Show 1 more citation
    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    2. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

    3. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    4. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition and free of infestation by rodents, birds insects, and other vermin.

    5. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    Show 3 more citations
    1. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.

    2. Written procedures followed

      Procedures for the preparation of master production and control records are not described in a written procedure.

    3. Aseptic Processing Area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.

  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  5. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  6. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  7. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    2. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    3. Accurate reproduction included

      Batch production and control records for each batch of drug product produced do not include an accurate reproduction of the appropriate master production or control record which was checked for accuracy, dated and signed.

    4. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.

    5. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.

    Show 1 more citation
    1. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing, processing, and packing of drug products is not appropriate for the duties they perform.

  8. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Product flow through building is inadequate

      The flow of components, drug product containers, closures, and drug products though the building is not designed to prevent contamination.

    2. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.

    3. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.

    4. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the prior to release.

    5. Components withheld from use pending release

      Each lot of is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.

    Show 5 more citations
    1. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    2. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

    3. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing, processing, packing, and holding of drug products is not appropriate for the duties they perform.

    4. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    5. Defined areas of adequate size for operations

      The control systems necessary to prevent contamination or mix-ups are deficient.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Dec 4, 2025. Each one asked for a Form 483.

  • Inspection ending Sep 5, 2025OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Dec 4, 2025FDA-FOIA-2025-13602Form 483· 1 of 5 sitesRecords released
  • Inspection ending Mar 30, 2023OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jul 3, 2025FDA-FOIA-2025-8246Form 483Directed Requester to Publically Available Information

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 14 sections of 21 CFR in FDA’s published citations for this facility’s 5 inspections, with how many of them cited each.

Show all 14

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.

Other FEIs recorded as Central Admixture Pharmacy Services Inc

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3009590582 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3009590582. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.