Central Admixture Pharmacy Services Inc
211 Summit Pkwy Ste 122, Homewood, Alabama, United States
FEI 1000221951
FDA has 4 inspections on file for Central Admixture Pharmacy Services Inc in Homewood, Alabama (FEI 1000221951), from 2009 to 2013. The latest ended on and was classified OAI, official action indicated. FDA has also posted a Form 483 dated Oct 16, 2015 that FDAgent has not matched to an inspection on the Data Dashboard.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 12 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 4, 2009–2013
- 3 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 4
- 2 posted 483s not matched to an inspection
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Protective Apparel Not Worn
Protective apparel is not worn as necessary to protect drug products from contamination.
Lab controls established, including changes
The establishment of laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Equipment for Environmental Control
Equipment for adequate control over air pressure is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Show 7 more citations
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
Written procedures lacking for use of pesticides etc.
Written procedures are lacking for the use of cleaning and sanitizing agents designed to prevent the contamination of drug products.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Extent of discrepancy, failure investigations
Investigations of an unexplained discrepancy did not extend to other drug products that may have been associated with the specific failure or discrepancy.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Retention time of reserve samples, in general
Reserve samples for drug products are not retained for one year after the expiration date of the drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance23 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
Written distribution procedure
Written distribution procedures are not followed.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Approve or reject procedures or specs
The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality, and purity of drug products.
Stability sample storage conditions described
The written stability program for drug products does not describe the storage conditions for samples retained for testing.
Show 18 more citations
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Protection from external factors
Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.
Reserve samples identified, representative, stored
Reserve drug product samples are not retained and stored under conditions consistent with product labeling.
Buildings not maintained in good state of repair
Buildings used in the processing, packing, and holding of a drug product are not maintained in a good state of repair.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature and light so that their identity, strength, quality, and purity are not affected.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Examination on receipt, before acceptance
Each container or grouping of containers of components, drug product containers, and closures is not examined visually upon receipt and before acceptance for appropriate labeling as to contents, container damage, broken seals, and contamination.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
Failure to submit ADE report
Adverse drug experience information has not been reported to FDA.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not reviewed and approved by the quality control unit.
Equipment for Environmental Control
Equipment for adequate control over humidity and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Rejecting When Specifications Not Met
Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.
Retest of approved components/containers/closures
Approved components are not retested or reexamined as appropriate for identity, strength, quality and purity after exposure to conditions that might have an adverse effect with subsequent approval or rejection by the quality control unit.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
Regulations FDA cited here
The 27 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.165Testing and release for distribution3 of 3
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling2 of 3
- 21 CFR 211.166Stability testing2 of 3
- 21 CFR 211.167Special testing requirements2 of 3
- 21 CFR 211.170Reserve samples2 of 3
- 21 CFR 211.192Production record review2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.28Personnel responsibilities1 of 3
Show all 27
- 21 CFR 211.56Sanitation1 of 3
- 21 CFR 211.58Maintenance1 of 3
- 21 CFR 211.63Equipment design, size, and location1 of 3
- 21 CFR 211.67Equipment cleaning and maintenance1 of 3
- 21 CFR 211.80General requirements1 of 3
- 21 CFR 211.82Receipt and storage of untested components, drug product containers, and closures1 of 3
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 3
- 21 CFR 211.87Retesting of approved components, drug product containers, and closures1 of 3
- 21 CFR 211.94Drug product containers and closures1 of 3
- 21 CFR 211.100Written procedures; deviations1 of 3
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 3
- 21 CFR 211.113Control of microbiological contamination1 of 3
- 21 CFR 211.125Labeling issuance1 of 3
- 21 CFR 211.142Warehousing procedures1 of 3
- 21 CFR 211.150Distribution procedures1 of 3
- 21 CFR 211.160General requirements1 of 3
- 21 CFR 211.180General requirements1 of 3
- 21 CFR 211.198Complaint files1 of 3
- 21 CFR 310.305Records and reports concerning adverse drug experiences on marketed prescription drugs for human use without approved new drug applications1 of 3
Other FEIs recorded as Central Admixture Pharmacy Services Inc
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Central Admixture Pharmacy Services IncFEI 3014307835Phoenix, Arizona, United States
Last inspected 2025-09-05OAI
Central Admixture Pharmacy Services IncFEI 3009590582Allentown, Pennsylvania, United States
Last inspected 2025-09-05OAI
Central Admixture Pharmacy Services IncFEI 3004378804San Diego, California, United States
Last inspected 2023-08-25OAI
Central Admixture Pharmacy Services IncFEI 3011755753Cranberry Township, Pennsylvania, United States
Last inspected 2022-05-04VAI
Central Admixture Pharmacy Services IncFEI 3005292119New Orleans, Louisiana, United States
Last inspected 2021-05-24VAI
Central Admixture Pharmacy Services IncFEI 3003693389Valley View, Ohio, United States
Last inspected 2016-01-21VAI
Central Admixture Pharmacy Services IncFEI 3002831368Beltsville, Maryland, United States
Last inspected 2009-07-01VAI
Central Admixture Pharmacy Services IncFEI 3003244004Kansas City, Missouri, United States
Last inspected 2009-06-30VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000221951 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000221951. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.