Element Materials Technology Oakland-Concord
2341 Stanwell Dr, Concord, California, United States
FEI 3006616583DUNS 792157906
FDA has 5 inspections on file for Element Materials Technology Oakland-Concord in Concord, California (FEI 3006616583), from 2009 to 2026. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Seven of the eight FOIA requests for this site have asked FDA for this inspection's records.
No warning letter, court action or import refusal is filed under this FEI.
Six regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for analysis, through Dec 31, 2026. Its registrant is Element Materials Technology Oakland - Concord Inc. (D-U-N-S 792157906).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 5, 2009–2026
- 1 OAI · 3 VAI · 1 NAI
- Inspections with 483 observations shown
- 4 of 5
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 8 requests, latest Oct 8, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Written record of investigation incomplete
Written records of investigations into the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.
Calculations performed are in the records
Laboratory records do not include a record of all calculations performed in connection with the test.
Following/documenting laboratory controls
Established test procedures are not followed.
Show 1 more citation
Calibration/Inspection/Checking not done
Routine inspection of mechanical equipment is not performed according to a written program designed to assure proper performance.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning SOPs/equipment protection
Procedures for the cleaning and maintenance of equipment are deficient regarding the protection of clean equipment from contamination prior to use.
Defined areas of adequate size for operations
The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Equipment for Environmental Control
Equipment for adequate control over air pressure, micro-organisms, dust and humidity is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Calibration/Inspection/Checking not done
Routine calibration of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Show 9 more citations
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Drains--Size, Back-siphonage Prevention
Drains are not provided with an air break or other mechanical device to prevent back-siphonage where connected directly with a sewer.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Adequate ventilation not provided
Adequate ventilation is not provided.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate standards, sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Buildings not maintained in good state of repair
Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function.
Calibration - at intervals, written program, remedial action
The calibration of gauges is not done at suitable intervals in accordance with an established written program.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Following/documenting laboratory controls
Established test procedures and laboratory control mechanisms are not followed and documented at the time of performance.
Written calibration procedures
Written calibration procedures for instruments, apparatus, gauges, and recording devices are deficient in that they do not include specific directions and limits for accuracy and precision.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Eight requests to FDA under the Freedom of Information Act named this site, most recently on Oct 8, 2026.
Inspection ending Jan 30, 2026OAI
7 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Apr 13, 2026. FDAgent holds no copy that FDA posted.
- Oct 8, 2026FDA-FOIA-2026-9811EIRClosed
- Aug 14, 2026FDA-FOIA-2026-7889Form 483· 1 of 4 sitesOpen
- Jul 5, 2026FDA-FOIA-2026-6384Form 483 + EIRRecords released
- May 11, 2026FDA-FOIA-2026-4805Form 483· 1 of 5 sitesWithdrawn
- May 5, 2026FDA-FOIA-2026-4455Form 483Records released
- Apr 6, 2026FDA-FOIA-2026-3367Form 483· 1 of 4 sitesRecords released
- Mar 13, 2026FDA-FOIA-2026-2519Form 483· 1 of 5 sitesRecords released
Inspection ending Mar 22, 2022VAI
1 request. In the inspection history above.
- Oct 8, 2026FDA-FOIA-2026-9808EIROpen
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 13 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.160General requirements4 of 4
- 21 CFR 211.22Responsibilities of quality control unit3 of 4
- 21 CFR 211.42Design and construction features2 of 4
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 4
- 21 CFR 211.192Production record review2 of 4
- 21 CFR 211.25Personnel qualifications1 of 4
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 4
- 21 CFR 211.48Plumbing1 of 4
Show all 13
- 21 CFR 211.58Maintenance1 of 4
- 21 CFR 211.67Equipment cleaning and maintenance1 of 4
- 21 CFR 211.100Written procedures; deviations1 of 4
- 21 CFR 211.113Control of microbiological contamination1 of 4
- 21 CFR 211.194Laboratory records1 of 4
FDA drug establishment registration
FDA registration search- Registered operations
- Analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Element Materials Technology Oakland - Concord Inc.D-U-N-S 792157906
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3006616583 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3006616583. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.