Skip to content

Precision Science Inc

1517 W Knudsen Dr, Phoenix, Arizona, United States

FEI 3004344227DUNS 808156215

FDA has 11 inspections on file for Precision Science Inc in Phoenix, Arizona (FEI 3004344227), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 5 citations from this inspection. They are listed below. One FOIA request has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Four regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis and medicated animal feed manufacturing, through Dec 31, 2026. Its registrant is Precision Science Inc. (D-U-N-S 808156215).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
11, 2009–2025
0 OAI · 5 VAI · 6 NAI
Inspections with 483 observations shown
4 of 11
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
1 request, latest Dec 9, 2025
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

11 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food Additives5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies do not include the conclusions and follow-up.

    2. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    3. Design suitable to facilitate maintenance and operation

      Equipment used in the manufacture and processing of Type A medicated articles is not of suitable design to facilitate maintenance and operation for its intended purpose.

    4. Test method reliability

      Laboratory controls do not include adequate provisions to check the reliability, accuracy and precision of laboratory test procedures.

    5. Maintenance

      Equipment used for the manufacture and processing of Type A medicated articles is not maintained in a clean and orderly manner to facilitate maintenance and operation.

  2. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  3. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Maintenance

      Equipment used for the manufacture and processing of Type A medicated articles is not maintained in a clean and orderly manner to facilitate maintenance and operation.

    2. Backup data not assured as exact and complete

      Backup data is not assured as secure from alteration, erasure or loss through keeping hard copy or alternate systems.

    3. Lack of quality control unit

      There is no quality control unit.

    4. Adjustment, cleaning, maintenance, uniformity, reliability

      Equipment used in the manufacture and processing of Type A medicated articles is not constructed to facilitate exclusion of contaminants, including cross contaminants.

    5. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the storage and handling of components and drug product containers.

    Show 2 more citations
    1. Written Procedures Not Followed

      Written procedures are not followed for the identification, storage and handling of components and drug product containers.

    2. Buildings not maintained in good state of repair

      Buildings used in the processing of a drug product are not maintained in a good state of repair.

  4. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Review of representative number of batches

      Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

  5. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  6. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  7. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  8. NAINo objectionable conditions that need follow-upVeterinary · Pre-Approval Eval. of Animal Drugs and Food AdditivesNone
  9. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesCitations not published
  10. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  11. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Defined areas of adequate size for operations

      The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.

    2. Strict control not exercised over labeling issued

      Strict control is not exercised over labeling issued for use in drug product labeling operations.

    3. Adjustment, cleaning, maintenance, uniformity, reliability

      Equipment used in the manufacture, processing, and packaging of Type A medicated articles is not constructed to facilitate cleaning and exclusion of contaminants, including cross contaminants.

    4. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    5. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    Show 4 more citations
    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    2. Test method reliability

      Laboratory controls do not include adequate provisions to check the reliability, accuracy, and precision of laboratory test procedures.

    3. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    4. Calibration/Inspection/Checking not done

      Routine calibration, inspection, and checking of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Dec 9, 2025. It asked for a Form 483.

  • Inspection ending Oct 24, 2025VAI

    1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Mar 20, 2026. FDAgent holds no copy that FDA posted.

    1. Dec 9, 2025FDA-FOIA-2025-13685Form 483· 1 of 5 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 13 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 11 inspections, with how many of them cited each.

Show all 13

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis, medicated animal feed manufacturing
Registration runs through
Dec 31, 2026
Registrant
Precision Science Inc.D-U-N-S 808156215

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004344227 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004344227. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.