Skip to content

21 CFR 226.30: Equipment

FDA's inspection data lists 7 Form 483 citations of 21 CFR 226.30 at 3 facilities, from August 2009 to October 24, 2025.

Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.

Form 483 citations
7
At 5 inspections
Facilities cited
3
Distinct FEIs
Most recent citation
Oct 24, 2025
Precision Science Inc
Warning letters
0
State a violation of it

The regulation

The current text of 21 CFR 226.30 from the Electronic Code of Federal Regulations.

§ 226.30 Equipment.

Equipment used for the manufacture, processing, packaging, bulk shipment, labeling, holding, or control of Type A medicated article(s) or their components shall be maintained in a clean and orderly manner and shall be of suitable design, size, construction, and location to facilitate maintenance and operation for its intended purpose. The equipment shall:

(a) Be so constructed that any surfaces that come into contact with Type A medicated article(s) are suitable, in that they are not reactive, additive, or absorptive to an extent that significantly affects the identity, strength, quality, or purity of the Type A medicated article(s) or its components.

(b) Be so constructed that any substance required for the operation of the equipment, such as lubricants, coolants, etc., may be employed without hazard of becoming an unsafe additive to the Type A medicated article(s).

(c) Be constructed to facilitate adjustment, cleaning, and maintenance, and to assure uniformity of production and reliability of control procedures and to assure the exclusion from Type A medicated article(s) of contamination, including cross-contamination from manufacturing operations.

(d) Be suitably grounded electrically to prevent lack of uniform mixing due to electrically charged particles.

(e) Be of suitable size and accuracy for use in any intended measuring, mixing, or weighing operations.

21 CFR Part 226: Current Good Manufacturing Practice for Type a Medicated Articles, Subpart BRead on eCFR

Citations by year

Form 483 citations of 21 CFR 226.30 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).

Peak: 2 in 2009

Form 483 citations of 21 CFR 226.30 by inspection year
YearForm 483 citations
20092
20121
20222
20252

How FDA words this citation

FDA's short descriptions and citation text on these 7 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.

Short descriptions

  • Adjustment, cleaning, maintenance, uniformity, reliability2 citations
  • Design suitable to facilitate maintenance and operation2 citations
  • Maintenance2 citations
  • Suitable size and accuracy for intended use1 citations

Citation text

  • “Equipment used for the manufacture and processing of Type A medicated articles is not maintained in a clean and orderly manner to facilitate maintenance and operation.”2 citations
  • “Equipment used in the manufacture and processing of Type A medicated articles is not constructed to facilitate exclusion of contaminants, including cross contaminants.”1 citations
  • “Equipment used in the manufacture and processing of Type A medicated articles is not of suitable design to facilitate maintenance and operation for its intended purpose.”1 citations
  • “Equipment used in the manufacture of Type A medicated articles is not of suitable design to facilitate maintenance and operation for its intended purpose.”1 citations
Show 2 more
  • “Equipment used in the manufacture, processing, and packaging of Type A medicated articles is not constructed to facilitate cleaning and exclusion of contaminants, including cross contaminants.”1 citations
  • “Equipment used in the production of Type A medicated articles is not of suitable accuracy for the intended measuring operations.”1 citations

Facilities cited most recently

The latest inspections where FDA cited 21 CFR 226.30, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.

  • Precision Science Inc2025-10-24 · FEI 3004344227Design suitable to facilitate maintenance and operation
  • Precision Science Inc2022-09-23 · FEI 3004344227Maintenance
  • Huvepharma, Inc.2012-02-21 · FEI 1910641Design suitable to facilitate maintenance and operation
  • Precision Science Inc2009-09-18 · FEI 3004344227Adjustment, cleaning, maintenance, uniformity, reliability
  • Bio Agri Mix LP2009-08-27 · FEI 3002809456Suitable size and accuracy for intended use

Often cited at the same inspection

Of the 5 inspections where FDA cited 21 CFR 226.30, the share where it also cited each of these sections.

Ask FDAgent about 21 CFR 226.30

FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
  • Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
  • A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 226.30; FDAgent quotes that sentence exactly.
  • FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.