Huvepharma, Inc.
1301 Iowa Ave, Longmont, Colorado, United States
FEI 1910641
FDA has 7 inspections on file for Huvepharma, Inc. in Longmont, Colorado (FEI 1910641), from 2010 to 2019. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 5 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Six regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 7, 2010–2019
- 0 OAI · 6 VAI · 1 NAI
- Inspections with 483 observations shown
- 5 of 7
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Approval and review of procedures
Written procedures are not drafted, reviewed and approved by the appropriate organizational units and reviewed and approved by the quality control unit.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Sampling and testing procedures described
Written specifications for laboratory controls do not include a description of the sampling procedures used.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Contract drug products--lack of responsibility
The quality control unit lacks responsibility for approving or rejecting drug products under contract by another company.
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Written program not followed
The written stability testing program is not followed.
Adequate lab facilities not available
Adequate lab facilities for testing and approval or rejection of components and drug products are not available to the quality control unit.
Show 5 more citations
Failure to meet specifications
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning a failure of one or more distributed batches of a drug to meet the specifications established for it in the application.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Written sanitation procedures lacking
There is a lack of written procedures describing in sufficient detail the methods, equipment and materials to be used for sanitation.
Written records kept in individual logs
Written records of major equipment use are not included in individual equipment logs.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written records kept in individual logs
Written records of major equipment maintenance and use are not included in individual equipment logs.
Lab controls established, including changes
The establishment of laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit.
input/output verification
Input to and output from the computer, related systems of formulas and records or data are not checked for accuracy.
Written program not followed
The written stability testing program is not followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Show 4 more citations
Review of representative number of batches
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.
Complete Test Data
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration/Inspection/Checking not done
Routine calibration of automatic and electronic equipment is not performed according to a written program designed to assure proper performance.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Automated equipment - assurance of proper performance
Adequate quality control procedures are not used to assure proper performance of mechanical equipment used in the production of Type A medicated articles.
Design suitable to facilitate maintenance and operation
Equipment used in the manufacture of Type A medicated articles is not of suitable design to facilitate maintenance and operation for its intended purpose.
Cleaning to prevent contamination of Type A articles
Failure to use adequate procedures for cleaning of those parts of equipment which come into contact with drug components of Type A medicated articles, to avoid contamination of Type A medicated articles.
- NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
Regulations FDA cited here
The 15 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 211.68Automatic, mechanical, and electronic equipment3 of 5
- 21 CFR 211.100Written procedures; deviations3 of 5
- 21 CFR 211.192Production record review3 of 5
- 21 CFR 211.22Responsibilities of quality control unit2 of 5
- 21 CFR 211.160General requirements2 of 5
- 21 CFR 211.166Stability testing2 of 5
- 21 CFR 211.182Equipment cleaning and use log2 of 5
- 21 CFR 211.56Sanitation1 of 5
Show all 15
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 5
- 21 CFR 211.180General requirements1 of 5
- 21 CFR 211.194Laboratory records1 of 5
- 21 CFR 314.81Other postmarketing reports1 of 5
- 21 CFR 226.1Current good manufacturing practice1 of 5
- 21 CFR 226.30Equipment1 of 5
- 21 CFR 226.40Production and control procedures1 of 5
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1910641 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1910641. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.