Bio Agri Mix LP
11 Ellens Street, Mitchell, Canada
FEI 3002809456DUNS 242075476
FDA has 5 inspections on file for Bio Agri Mix LP in Mitchell, Canada (FEI 3002809456), from 2009 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 2 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.160(a).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for packing, labeling and analysis, through Dec 31, 2027. Its registrant is Bio Agri Mix LP (D-U-N-S 242075476).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2009–2024
- 0 OAI · 5 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 5
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 1 request, latest May 5, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature so that their identity, strength, quality, and purity are not affected.
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food Additives3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Test method reliability
Laboratory controls do not include adequate provisions to check the reliability of laboratory test procedures.
Following/documenting laboratory controls
Established laboratory control mechanisms are not followed.
Written program not followed
The written stability testing program is not followed.
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food Additives9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning to prevent contamination of Type A articles
Failure to use adequate procedures for cleaning of those parts of equipment which come into contact with drug components of Type A medicated articles, to avoid contamination of Type A medicated articles.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals with provisions for remedial action in the event accuracy and/or precision limits are not met.
Suitable size and accuracy for intended use
Equipment used in the production of Type A medicated articles is not of suitable accuracy for the intended measuring operations.
Following/documenting laboratory controls
Established laboratory control mechanisms are not followed.
Components receiving, testing, handling, et. al.
Drug components used in the manufacture and processing of Type A medicated articles are not controlled in a manner to maintain the identification of such articles.
Show 4 more citations
Test methods
The accuracy and reproducibility of test methods have not been established.
Representative Samples
Representative samples are not taken of each shipment of each lot of components for testing or examination.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on May 5, 2025. It asked for a Form 483.
Inspection ending Jul 29, 2022VAI
1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Oct 22, 2025. FDAgent holds no copy that FDA posted.
- May 5, 2025FDA-FOIA-2025-3968Form 483· 1 of 3 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 12 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.160General requirements2 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 3
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 3
- 21 CFR 211.100Written procedures; deviations1 of 3
- 21 CFR 211.142Warehousing procedures1 of 3
- 21 CFR 211.165Testing and release for distribution1 of 3
- 21 CFR 211.166Stability testing1 of 3
- 21 CFR 211.192Production record review1 of 3
Show all 12
- 21 CFR 226.58Laboratory controls1 of 3
- 21 CFR 226.30Equipment1 of 3
- 21 CFR 226.40Production and control procedures1 of 3
- 21 CFR 226.42Components1 of 3
FDA drug establishment registration
FDA registration search- Registered operations
- Packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Bio Agri Mix LPD-U-N-S 242075476
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3002809456 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3002809456. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.