21 CFR 226.58: Laboratory controls
FDA's inspection data lists 11 Form 483 citations of 21 CFR 226.58 at 7 facilities, from September 2009 to October 24, 2025.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 11
- At 9 inspections
- Facilities cited
- 7
- Distinct FEIs
- Most recent citation
- Oct 24, 2025
- Precision Science Inc
- Warning letters
- 0
- State a violation of it
The regulation
The current text of 21 CFR 226.58 from the Electronic Code of Federal Regulations.
§ 226.58 Laboratory controls.
Laboratory controls shall include the establishment of adequate specifications and test procedures to assure that the drug components and the Type A medicated article(s) conform to appropriate standards of identity, strength, quality, and purity. Laboratory controls shall include:
(a) The establishment of master records containing appropriate specifications and a description of the test procedures used to check them for each kind of drug component used in the manufacture of Type A medicated article(s). This may consist of the manufacturer's or supplier's statement of specifications and methods of analyses.
(b) The establishment of specifications for Type A medicated article(s) and a description of necessary laboratory test procedures to check such specifications.
(c) Assays which shall be made of representative samples of finished Type A medicated article(s) in accordance with the following schedule:
(1) Each batch of a Type A medicated article(s) manufactured from an undiluted drug shall be assayed for its drug component(s).
(2) In the case of Type A medicated article(s) which are manufactured by dilution of Type A medicated article(s) assayed in accordance with paragraph (c)(1) of this section, each batch shall be assayed for its drug component(s) with the first five consecutive batches assaying within the limitations, followed thereafter by assay of representative samples of not less than 5 percent of all batches produced. When any batch does not assay within limitations, each batch should again be assayed until five consecutive batches are within limitations.
(d) A determination establishing that the drug components remain uniformly dispersed and stable in the Type A medicated article(s) under ordinary conditions of shipment, storage, and use. This may consist of a determination on a Type A medicated article(s) of substantially the same formula and characteristics. Suitable expiration dates shall appear on the labels of the Type A medicated article(s) to assure that the articles meet the appropriate standards of identity, strength, quality, and purity at the time of use.
(e) Adequate provision to check the reliability, accuracy, and precision of any laboratory test procedure used. The official methods in “Methods of Analysis of the Association of Official Analytical Chemists,” 1 methods described in an official compendium, and any method submitted as a part of a food additive petition or new-drug application that has been accepted by the Food and Drug Administration shall be regarded as meeting this provision.
1 Copies may be obtained from: AOAC INTERNATIONAL, 481 North Frederick Ave., suite 500, Gaithersburg, MD 20877.
(f) Provisions for the maintenance of the results of any assays, including dates and endorsement of analysts. Such records shall be retained in the possession of the manufacturer and shall be maintained for a period of at least 2 years after distribution by the manufacturer of the Type A medicated article(s) has been completed.
21 CFR Part 226: Current Good Manufacturing Practice for Type a Medicated Articles, Subpart CRead on eCFR
Citations by year
Form 483 citations of 21 CFR 226.58 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 3 in 2013
| Year | Form 483 citations |
|---|---|
| 2009 | 1 |
| 2010 | 2 |
| 2013 | 3 |
| 2014 | 2 |
| 2015 | 1 |
| 2025 | 2 |
How FDA words this citation
FDA's short descriptions and citation text on these 11 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Test method reliability5 citations
- Components uniformly dispersed and stable2 citations
- Specifications, test procedures - Type A medicated articles2 citations
- Expiration date lacking on Type A article1 citations
- Specifications, test procedures - components1 citations
Citation text
- “Laboratory controls do not include adequate provisions to check the reliability, accuracy, and precision of laboratory test procedures.”4 citations
- “No determination has been made that the drug components remain uniformly dispersed and stable in Type A medicated articles under ordinary conditions of shipment, storage and use.”2 citations
- “Laboratory controls do not include adequate provisions to check the reliability of laboratory test procedures.”1 citations
- “Laboratory controls do not include adequate specifications and test procedures to assure that drug components used in the manufacture of Type A medicated articles conform to appropriate specifications.”1 citations
Show 2 more
- “Laboratory controls do not include the establishment of adequate specifications and a description of laboratory test procedures to check specifications to assure that Type A medicated articles conform to appropriate specifications.”1 citations
- “Laboratory controls do not include the establishment of adequate specifications to assure that Type A medicated articles conform to appropriate specifications.”1 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 226.58, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
- Phibro Animal Health Corporation2015-02-25 · FEI 1000122177Components uniformly dispersed and stable
Show 3 more
Often cited at the same inspection
Of the 9 inspections where FDA cited 21 CFR 226.58, the share where it also cited each of these sections.
- 21 CFR 211.160General requirements2 (22%)
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 (22%)
- 21 CFR 226.30Equipment2 (22%)
- 21 CFR 211.125Labeling issuance1 (11%)
- 21 CFR 211.142Warehousing procedures1 (11%)
- 21 CFR 211.166Stability testing1 (11%)
Ask FDAgent about 21 CFR 226.58
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 226.58; FDAgent quotes that sentence exactly.