A.P. Deauville, LLC
3700 Glover Rd, Easton, Pennsylvania, United States
FEI 3004007943DUNS 100941835
FDA has 7 inspections on file for A.P. Deauville, LLC in Easton, Pennsylvania (FEI 3004007943), from 2011 to 2025. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 13 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Four FOIA requests have asked FDA for this inspection's 483.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
14 regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and labeling, through Dec 31, 2027. Its registrant is A.P. Deauville, LLC (D-U-N-S 100941835).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 7, 2011–2025
- 3 OAI · 4 VAI · 0 NAI
- Inspections with 483 observations shown
- 7 of 7
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 4 requests, latest Sep 29, 2025
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Review of representative number of batches
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Written program not followed
The written stability testing program is not followed.
Show 8 more citations
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing, processing and packaging of the drug product.
No written record of investigation
Written records are not made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling and drug products conform to appropriate standards of identity, strength, quality and purity.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training required to perform their assigned functions.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing, processing and packaging of the drug product.
Written procedures not established/followed
Written procedures are not for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that components, drug product containers, closures and labeling conform to appropriate standards of identity, strength, quality and purity.
Show 4 more citations
Written program not followed
The written stability testing program is not followed.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Incoming material area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the receipt, identification, storage, and withholding from use of components pending sampling, testing, or examination by the quality control unit before release for manufacturing or packaging.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Calibration - at intervals, written program, remedial action
The calibration of instruments, apparatus and recording devices is not done at suitable intervals in accordance with an established written program.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Show 9 more citations
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Test methods
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing and packaging of the drug product.
Written program not followed
The written stability testing program is not followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration/Inspection/Checking not done
Routine calibration, inspection and checking of automatic and mechanical equipment is not performed according to a written program designed to assure proper performance.
Establishment of calibration procedures
Procedures describing the calibration of instruments, apparatus, gauges and recording devices are not written or followed.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used and description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
Analytical methods
Your laboratory analytical methods are not suitable for their intended use, are not sufficiently specific, are not accurate and are not reproducible.
Show 8 more citations
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, drug product containers, closures, in-process materials and labeling conform to appropriate standards of identity, strength, quality and purity.
Weighing/measuring/subdividing supervision
Component weighing, measuring and subdividing operations are not adequately supervised.
Inadequate number of personnel
The number of qualified personnel is inadequate to perform and supervise the manufacture, processing, packing and holding of each drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used and description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance .
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed .
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing , processing , packaging and holding of the drug product.
Establishment of calibration procedures
Procedures describing the calibration of instruments, apparatus, gauges and recording devices are not written or followed .
Show 8 more citations
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed .
Distribution Recall System
The distribution system is deficient in that each lot of drug product cannot be readily determined to facilitate its recall if necessary.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete manufacturing , instructions and specifications .
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices .
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Weighing/measuring/subdividing supervision
Component weighing , measuring and subdividing operations are not adequately supervised.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications , standards , sampling plans and test procedures designed to assure that components , drug product containers , closures , in-process materials , labeling and drug products conform to appropriate standards of identity, strength, quality and purity.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration/Inspection/Checking not done
Routine calibration of equipment is not performed according to a written program designed to assure proper performance.
Component addition checked by 2nd person
Each component is not added to a batch by one person and verified by a second person.
Buildings of Suitable Size, Construction, Location
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable size and construction to facilitate cleaning, maintenance, and proper operations.
Actual yield, % of theoretical yield
The batch production and control records do not include a statement of the actual yield and percentage of theoretical yield at appropriate stages of processing for each batch of drug product produced.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function and current good manufacturing practices.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on Sep 29, 2025. Each one asked for a Form 483.
Inspection ending Jan 23, 2025OAI
4 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Aug 28, 2025. FDAgent holds no copy that FDA posted.
- Sep 29, 2025FDA-FOIA-2025-11396Form 483· 1 of 4 sitesRecords released
- Aug 5, 2025FDA-FOIA-2025-8802Form 483· 1 of 3 sitesRecords released
- Jun 16, 2025FDA-FOIA-2025-7675Form 483· 1 of 10 sitesWithdrawn
- Apr 30, 2025FDA-FOIA-2025-3945Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 24 sections of 21 CFR in FDA’s published citations for this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 211.25Personnel qualifications6 of 7
- 21 CFR 211.67Equipment cleaning and maintenance6 of 7
- 21 CFR 211.22Responsibilities of quality control unit5 of 7
- 21 CFR 211.160General requirements5 of 7
- 21 CFR 211.100Written procedures; deviations4 of 7
- 21 CFR 211.103Calculation of yield4 of 7
- 21 CFR 211.110Sampling and testing of in-process materials and drug products4 of 7
- 21 CFR 211.166Stability testing4 of 7
Show all 24
- 21 CFR 211.198Complaint files4 of 7
- 21 CFR 211.68Automatic, mechanical, and electronic equipment3 of 7
- 21 CFR 211.101Charge-in of components3 of 7
- 21 CFR 211.165Testing and release for distribution3 of 7
- 21 CFR 211.194Laboratory records3 of 7
- 21 CFR 211.42Design and construction features2 of 7
- 21 CFR 211.56Sanitation1 of 7
- 21 CFR 211.63Equipment design, size, and location1 of 7
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 7
- 21 CFR 211.137Expiration dating1 of 7
- 21 CFR 211.150Distribution procedures1 of 7
- 21 CFR 211.180General requirements1 of 7
- 21 CFR 211.186Master production and control records1 of 7
- 21 CFR 211.188Batch production and control records1 of 7
- 21 CFR 211.192Production record review1 of 7
- 21 CFR 212.60What requirements apply to the laboratories where I test components, in-process materials, and finished PET drug products?1 of 7
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, labeling
- Registration runs through
- Dec 31, 2027
- Registrant
- A.P. Deauville, LLCD-U-N-S 100941835
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004007943 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004007943. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.