Dextrum Laboratories Inc.

6993 Nw 82nd Ave Ste 20, Miami, Florida, United States

FEI 3003092372DUNS 007392322

FDA has 6 inspections on file for Dextrum Laboratories Inc. in Miami, Florida (FEI 3003092372), from 2012 to 2024. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Four of the six FOIA requests for this site have asked FDA for this inspection's 483.

FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations II). No court action or import refusal is filed under this FEI.

Eight regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, analysis and repacking, through Dec 31, 2027. Its registrant is Dextrum Laboratories Inc. (D-U-N-S 007392322).

Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
6, 2012–2024
2 OAI · 4 VAI · 0 NAI
Inspections with 483 observations shown
6 of 6
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
6 requests, latest Aug 29, 2025
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Component written specification

      Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.

    2. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    3. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

    4. Written program not followed

      The written stability testing program is not followed.

    5. Written in-process control procedures

      Written procedures are not followed that describe the tests and examinations to be conducted on appropriate samples of in-process materials of each batch.

    Show 1 more citation
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    2. Control procedures to monitor and validate performance

      Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    3. Representative Number of Batches for Annual Review

      The procedures for the annual quality standards record evaluation are deficient in that they do not address a review of a representative number of batches.

    4. Exhaust systems inadequate to control air contamination

      Adequate exhaust systems or other systems to control contaminants are lacking in areas where air contamination occurs during production.

    5. Complete instructions, procedures, specifications et. al.

      Master production and control records lack complete manufacturing and control instructions and sampling and testing procedures.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance10 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Reprocessing procedures not written or followed

      Procedures prescribing a system for reprocessing batches to insure that the reprocessed batches will conform with all established standards, specifications, and characteristics are not written.

    2. Calibration/Inspection/Checking not done

      Routine calibration of equipment is not performed according to a written program designed to assure proper performance.

    3. Identification of containers, lines, equipment

      All major equipment used during the production of a batch of drug product is not properly identified at all times to indicate the phase of processing of the batch.

    4. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and written.

    5. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

    Show 5 more citations
    1. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    2. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    4. Handling and Storage to Prevent Contamination

      There was a failure to handle and store components at all times in a manner to prevent contamination.

    5. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not recorded and justified.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Objectionable microbiological contamination

      Each lot of a component liable to objectionable microbiological contamination is deficiently subjected to microbiological tests before use.

    2. Backup file not maintained

      Failure to maintain a backup file of data entered into the computer or related system.

    3. Complete test data included in records

      Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

    4. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    5. Written procedures not established/followed

      Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    Show 2 more citations
    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and standards designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    2. Samples (various types) representative, identified properly

      Samples taken to determine conformance to appropriate written specifications for the acceptance of each lot within each shipment of components and drug product containers are not representative.

  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written procedures describing in detail

      There is a lack of written procedures describing in sufficient detail the identification and examination of labeling and packaging materials.

    2. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals .

    3. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    4. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    5. Microbiological Contamination Exam

      Each lot of a component that is liable to microbiological contamination that is objectionable in view of its intended use is not subjected to microbiological tests before use.

    Show 1 more citation
    1. Control procedures to monitor and validate performance

      Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Control procedures to monitor and validate performance

      Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    2. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.

    3. Inspection of packaging and labeling area

      Batch production and control records do not include results of the inspection of the packaging and labeling area before use for each batch of drug product produced.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    5. Lab controls established, including changes

      The establishment of test procedures including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit.

    Show 3 more citations
    1. Microbiological Contamination Exam

      Each lot of a component that is liable to microbiological contamination that is objectionable in view of its intended use is not subjected to microbiological tests before use.

    2. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used.

    3. Training--operations, GMPs, written procedures

      Employees are not given training in written procedures required by current good manufacturing practice regulations.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Six requests to FDA under the Freedom of Information Act named this site, most recently on Aug 29, 2025. Each one asked for a Form 483.

  • Inspection ending Aug 29, 2024OAI

    4 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Sep 11, 2025. FDAgent holds no copy that FDA posted.

    1. Aug 29, 2025FDA-FOIA-2025-10402Form 483Records released
    2. Feb 10, 2025FDA-FOIA-2025-1301Form 483· 1 of 4 sitesClosed
    3. Oct 18, 2024FDA-FOIA-2024-9232Form 483· 1 of 4 sitesClosed
    4. Oct 4, 2024FDA-FOIA-2024-8756Form 483· 1 of 5 sitesClosed
  • Inspection ending Jul 18, 2023OAI

    2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Jun 3, 2024FDA-FOIA-2024-4803Form 483Closed
    2. Oct 11, 2023FDA-FOIA-2023-8942Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 22 sections of 21 CFR in FDA’s published citations for this facility’s 6 inspections, with how many of them cited each.

Show all 22

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, analysis, repacking
Registration runs through
Dec 31, 2027
Registrant
Dextrum Laboratories Inc.D-U-N-S 007392322

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3003092372 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3003092372. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.